LB3, Faculty of Exact Sciences and Engineering, University of Madeira, Funchal, 9020-105, Portugal; CIIMAR, Interdisciplinary Centre of Marine and Environmental Research, University of Porto, Matosinhos, 4450-208, Portugal; CICECO, Aveiro Institute of Materials and Águeda School of Technology and Management, University of Aveiro, Águeda, 3754-909, Portugal
Auto-generated profile, based on publicly available information
Filipa Rodrigues
LB3, Faculty of Exact Sciences and Engineering, University of Madeira, Funchal, 9020-105, Portugal; CIIMAR, Interdisciplinary Centre of Marine and Environmental Research, University of Porto, Matosinhos, 4450-208, Portugal; CICECO, Aveiro Institute of Materials and Águeda School of Technology and Management, University of Aveiro, Águeda, 3754-909, Portugal
Bound extracellular polymeric substances (B-EPS) are extracellular polysaccharides tightly attached to cyanobacterial and microalgal cell surfaces, representing a high-value class of biopolymers with industrial potential. Selective extraction is technically challenging due to strong adhesion to the cell wall and potential co-extraction of soluble EPS. Conventional methods can be chemically aggressive and may involve high energy and/or solvent inputs, making solvent-free extraction routes desirable. In this work, four hydrothermal extraction techniques (reflux, autoclave, ultrasonic bath, and microwave) were evaluated for their ability to recover B-EPS from the marine cyanobacterium Chroococcus submarinus (BEA 1200B), followed by a harmonised ultrafiltration step. Each method was assessed for extraction efficiency and its impact on bulk descriptors (inorganic carry-over, ATR-FTIR, zeta potential, and thermal profiles) and morphology. Among the methods tested, autoclave extraction demonstrated the highest performance, yielding up to 2.5 times more B-EPS than the other methods and showing reduced inorganic carry-over after purification. Across all methods, the purified B-EPS fractions exhibited broadly comparable bulk profiles under the applied analytics. Response Surface Methodology (RSM) applied to the autoclave system identified temperature and extraction time as key variables; optimal conditions (biomass-to-solvent ratio 1 : 20 (w/v), 130 °C, 16 min) enabled >90% recovery. Coupling autoclave extraction with solvent-free ultrafiltration avoids solvent precipitation and the use of hazardous reagents, enabling desalting and removal of low-molecular-weight components. Using a photosynthetic marine strain supports seawater cultivation and biogenic CO2 uptake, aligning the workflow with carbon-mitigation goals.
The accurate quantification of soluble extracellular polymeric substances (S-EPS) in microalgal and cyanobacterial cultures requires methods that remain reliable across different culture media. This study optimised and validated an Alcian Blue-based assay strategy for S-EPS determination in culture media. Post-preparation dye mixing was optimised at 60 rpm for 60 min to ensure stable residual absorbance and reproducible readout. A base Alcian Blue concentration of 0.80 g/L (pH 2.5) was selected based on dye stability and dye-only linearity. The dye-only response remained stable across pH 3-12 and salinity 0-37 ‰, whereas Ca2+, Mg2+, and Fe2+ significantly reduced the dye response. Alcian Blue remained stable for up to 61 days at 4 °C, but only 7 days at room temperature. Spike-recovery assessment in the A. minutissima/BG11 culture system showed deviations within the 95 % prediction interval and recovery values close to 100 %, supporting quantitative application under this matrix condition. Two calibration levels were distinguished: dye-only calibration for instrumental quality control (R2 = 0.9999; 0.06-1.0 g/L; LOD = 0.006 g/L; LOQ = 0.021 g/L) and matrix-matched S-EPS calibrations to evaluate medium-dependent effects on quantification. No detectable matrix interference was observed in the BG11-based system, whereas Spirulina and ASP-12 media required matrix-matched calibration and 1.0 g/L Alcian Blue. After medium-specific optimisation and calibration, the assay provides a rapid, low-cost, low-sample-volume approach for repeated S-EPS quantification, supporting laboratory studies and routine monitoring of culture-based production systems, while reinforcing that reliable application requires matrix-effect assessment before quantitative use.