13 September 2023 in Science Robotics
The use of needles to access sites within organs is fundamental to many interventional medical procedures both for diagnosis and treatment. Safely and accurately navigating a needle through living tissue to a target is currently often challenging or infeasible because of the presence of anatomical obstacles, high levels of uncertainty, and natural tissue motion. Medical robots capable of automating needle-based procedures have the potential to overcome these challenges and enable enhanced patient care and safety. However, autonomous navigation of a needle around obstacles to a predefined target in vivo has not been shown. Here, we introduce a medical robot that autonomously navigates a needle through living tissue around anatomical obstacles to a target in vivo. Our system leverages a laser-patterned highly flexible steerable needle capable of maneuvering along curvilinear trajectories. The autonomous robot accounts for anatomical obstacles, uncertainty in tissue/needle interaction, and respiratory motion using replanning, control, and safe insertion time windows. We applied the system to lung biopsy, which is critical for diagnosing lung cancer, the leading cause of cancer-related deaths in the United States. We demonstrated successful performance of our system in multiple in vivo porcine studies achieving targeting errors less than the radius of clinically relevant lung nodules. We also demonstrated that our approach offers greater accuracy compared with a standard manual bronchoscopy technique. Our results show the feasibility and advantage of deploying autonomous steerable needle robots in living tissue and how these systems can extend the current capabilities of physicians to further improve patient care.
17 March 2021 in IEEE Robotics and Automation Letters
Lung cancer is one of the deadliest types of cancer, and early diagnosis is crucial for successful treatment. Definitively diagnosing lung cancer typically requires biopsy, but current approaches either carry a high procedural risk for the patient or are incapable of reaching many sites of clinical interest in the lung. We present a new sampling-based planning method for a steerable needle lung robot that has the potential to accurately reach targets in most regions of the lung. The robot comprises three stages: a transorally deployed bronchoscope, a sharpened piercing tube (to pierce into the lung parenchyma from the airways), and a steerable needle able to navigate to the target. Planning for the sequential deployment of all three stages under health safety concerns is a challenging task, as each stage depends on the previous one. We introduce a new backward planning approach that starts at the target and advances backwards toward the airways with the goal of finding a piercing site reachable by the bronchoscope. This new strategy enables faster performance by iteratively building a single search tree during the entire computation period, whereas previous forward approaches have relied on repeating this expensive tree construction process many times. Additionally, our method further reduces runtime by employing biased sampling and sample rejection based on geometric constraints. We evaluate this approach using simulation-based studies in anatomical lung models. We demonstrate in comparison with existing techniques that the new approach (i) is more likely to find a path to a target, (ii) is more efficient by reaching targets more than 5 times faster on average, and (iii) arrives at lower-risk paths in shorter time.
2 October 2020 in IEEE Access
The maximum curvature of a steerable needle in soft tissue is highly sensitive to needle shaft stiffness, which has motivated use of small diameter needles in the past. However, desired needle payloads constrain minimum shaft diameters, and shearing along the needle shaft can occur at small diameters and high curvatures. We provide a new way to adjust needle shaft stiffness (thereby enhancing maximum curvature, i.e. “steerability”) at diameters selected based on needle payload requirements. We propose helical dovetail laser patterning to increase needle steerability without reducing shaft diameter. Experiments in phantoms and ex vivo animal muscle, brain, liver, and inflated lung tissues demonstrate high steerability in soft tissues. These experiments use needle diameters suitable for various clinical scenarios, and which have been previously limited by steering challenges without helical dovetail patterning. We show that steerable needle targeting remains accurate with established controllers and demonstrate interventional payload delivery (brachytherapy seeds and radiofrequency ablation) through the needle. Helical dovetail patterning decouples steerability from diameter in needle design. It enables diameter to be selected based on clinical requirements rather than being carefully tuned to tissue properties. These results pave the way for new sensors and interventional tools to be integrated into high-curvature steerable needles.
9 July 2025 in Science Robotics
Safely and accurately navigating needles percutaneously or endoscopically to sites deep within the body is essential for many medical procedures, from biopsies to localized drug deliveries to tumor ablations. The advent of image guidance decades ago gave physicians information about the patient’s anatomy. We are now entering the era of AI (artificial intelligence) guidance, where AI can automatically analyze images, identify targets and obstacles, compute safe trajectories, and autonomously navigate a needle to a site with unprecedented accuracy and precision. We survey recent advances in the building blocks of AI guidance for medical needle deployment robots (perceiving anatomy, planning motions, perceiving instrument state, and performing motions) and discuss research opportunities to maximize the benefits of AI guidance for patient care.
17 March 2025 in IEEE Transactions on Robotics
Steerable needles are minimally invasive devices that can enable novel medical procedures by following curved paths to avoid critical anatomical obstacles. We introduce a new start pose robustness metric for steerable needle motion plans. A steerable needle deployment typically consists of a physician manually placing a steerable needle at a precomputed start pose on the surface of tissue and handing off control to a robot, which then autonomously steers the needle through the tissue to the target. The handoff between humans and robots is critical for procedure success, as even small deviations from a planned start pose change the steerable needle's reachable workspace. Our metric is based on a novel geometric method to efficiently compute how far the physician can deviate from the planned start pose in both position and orientation such that the steerable needle can still reach the target. We evaluate our metric through simulation in liver and lung scenarios. Our evaluation shows that our metric can be applied to plans computed by different steerable needle motion planners and that it can be used to efficiently select plans with large safe start regions.