21 April 2016 in IEEE Transactions on Power Delivery
This paper presents and discusses the concepts of a gapless-power-quality disturbance recorder (G-PQDR) and a novelty detector. In the G-PQDR, power signals are divided into continuous frames and the energy difference between an actual frame and a reference frame is used for comparison. If the current frame is different from the reference frame, it will be recorded in the equipment and it becomes the new reference frame; otherwise, the frame is discarded and the frequency of the fundamental component is stored. The G-PQDR is able to detect and record the waveforms of the previously known PQ disturbances as well as those of the PQ disturbances not yet observed in power systems, thanks to the novelty detection concept. This characteristic is important in the context of smart grids where hidden disturbances can be detected by this methodology. For efficient data storage by minimizing the volume of the data stored, the G-PQDR uses lossy and lossless compressors. This paper describes the entire process of detection and compression, and compares the performance of the proposed method with that of a commercial-power-quality data recorder. In addition, some of the prototype implementation details are presented.
19 October 2021 in IEEE Transactions on Industrial Informatics
The current scenario of electric power systems expansion requires the insertion of new devices and technologies, contributing to the establishment of smart grids. However, the more instruments are connected to the grid, the greater the amount of data resulting from the measurements, which can cause a bottleneck in data transferring. The present article addresses this problem by proposing a system that implements a novel and efficient real-time data compression method based on the power signal spectral content variation, focused on long-term gapless oscillographic analysis. This system also provides a high-fidelity reconstruction for full oscillography power quality analysis. Comparison results with synthetic and real signals using another gapless power quality disturbance recorder present in literature and a commercial power quality disturbance recorder show that the proposed technique is capable to achieve a compression rate more than ten times greater than both while providing a better reconstruction quality, reaching compression ratio values of up to 10780:1 for synthetic signals and 9470:1 for real signals.
1 August 2016 in Measurement
13 April 2024 in Journal of Control, Automation and Electrical Systems