1 October 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 July 2018 in Physics Letters B
6 December 2022 in Frontiers in Physics
At the Laboratori Nazionali del Sud of INFN (INFN-LNS) in Catania, the construction of the new Radioactive Ion Beams (RIBs) facility FRAISE (FRAgment In-flight SEparator) has reached its ending phase. The facility uses the in-flight technique based on a primary beam fragmentation impinging on light Be or C targets. FRAISE makes use of light and medium mass primary beams, having power up to ≈ 2–3 kW, leading to RIBs, whose intensities vary in the range of ≈ 103–107 pps, for nuclei far from and close to the stability valley, respectively. FRAISE aims at providing high-intensity and high-quality RIBs for nuclear physics experiments, also serving to interdisciplinary research areas, such as medical physics. Critical aspects for high-quality beams are the tuning and transport, representing time-consuming processes and requiring dedicated diagnostics and tagging devices measuring many features of RIBs. Some of these devices should be capable to operate in radioactively activated environments because of the expected 2 kW beam lost in the dipole after the production target. Due to its peculiar robustness to radioactive damage, Silicon Carbide (SiC) technology has been considered for the detection layer. In this view, an R&D campaign has been started aiming at developing the FRAISE facility, the new diagnostics system, and a new tagging device, the latter of which will be useful for the CHIMERA multidetector beamline. In this paper, we discuss the status and the perspectives of the facility with a focus on the RIBs opportunities.
16 October 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 July 2025 in Journal of Instrumentation
This contribution presents a selection of results obtained within the SAMOTHRACE ecosystem, specifically aimed at advancing the development of Silicon Carbide (SiC) detectors for applications in energy and timing measurements with radioactive ion beams. A particular focus is placed on the characterization of the time resolution performance of a 2×2 pixel SiC detector (1 cm2-100 μm thick). These results were achieved through a dedicated test, where a microchannel plate (MCP) detector was employed as a start timing reference, while the SiC detector served as the stop signal.
2 February 2026 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment