Chun Fang Li

Chun Fang Li

Auto-generated profile, based on publicly available information

Chun Fang Li

College of Mechanical and Vehicular Engineering, Changchun University

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
YZYingyong Zou
Yingyong Zou
YZYu Zhang
Yu Zhang
CLChun Fang Li
Chun Fang Li
ZSZhi Qiang Si
Zhi Qiang Si
LLLong Li
Long Li
In recent years, deep learning technology has been widely applied to bearing fault diagnosis, achieving significant progress. However, noise often masks fault characteristics, making feature extraction difficult and reducing diagnostic accuracy, which in turn hinders practical application. Therefore, this paper proposes a fault diagnosis model based on a gating mechanism and multi-scale feature fusion (multi-scale distributed convolution (MSDC)-Dense DGated convolutional neural network (CNN)). This model enhances noise resistance through a two-stage feature learning architecture: The first stage employs an MSDC module, which incorporates three parallel group convolutions with distinct dilation rates. This simultaneously filters noise while capturing multi-scale temporal features. Group CNN reduces parameter redundancy and strengthens local feature extraction. The second stage introduces a Dense DGated CNN block. This block dynamically suppresses noise interference through a product operation between feature branches and dilation-gated branches. A 1–1 convolution layer is added after convolutions with high dilation rates to mitigate the grid effect. Dense connections are employed to strengthen feature correlations. Additionally, the model incorporates a squeeze and excitation module that utilizes channel attention to amplify critical fault features while suppressing noise-dominated redundant information adaptively. The proposed model was validated on the CWRU and self-test datasets under various noise conditions. Experimental results demonstrate that the model achieves a diagnostic accuracy of 89.70% even in high-noise environments with a signal-to-noise ratio of −10 dB. Characterized by minimal parameters and strong anti-interference capabilities, it is well-suited for fault detection tasks in industrial time-series signals that are heavily influenced by substantial noise interference.

1 May 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
YZYingyong Zou
Yingyong Zou
YZYu Zhang
Yu Zhang
CLChunFang Li
ChunFang Li
ZSZhiQiang Si
ZhiQiang Si
LLLong Li
Long Li
As critical components in rotating machinery, bearing health status directly affects the operational safety of equipment and personnel. Therefore, effective bearing condition monitoring is of great importance. However, challenges such as scarce labeled samples, varying operating conditions, and strong noise interference severely restrict the performance of high-precision fault diagnosis. To address these issues, this paper proposes a fault diagnosis method that combines maximum mean discrepancy and a domain-adversarial neural network to reduce feature discrepancies under variable speed and load conditions. High-confidence pseudo-labels are adopted to improve diagnostic performance under semi-supervised settings. Based on the above strategies, a unified loss function is constructed and a high-precision bearing-fault diagnosis framework adaptable to varying working conditions is established. Meanwhile, a tailored convolutional auto-encoder (CAE) is designed for strong-noise environments to denoise vibration signals and provide high-quality inputs for the network. Experimental results demonstrate that, with ResNet14 as the backbone, the proposed feature alignment method achieves diagnostic accuracy exceeding 98% on both the Case Western Reserve University dataset and the self-built test dataset, even when only 5% of target-domain data are labeled. The constructed CAE module maintains reliable denoising performance even under a high noise level of −10 dB. The entire model contains 1531 973 parameters and requires only 3 s per training epoch. Accordingly, the proposed method is well-suited for semi-supervised domain-adaptive bearing fault diagnosis under real industrial scenarios.

1 October 2026 in Engineering Research Express
Verified
Journal Article
Closed access
YZYingyong Zou
Yingyong Zou
YZYu Zhang
Yu Zhang
CLChun Fang Li
Chun Fang Li
ZSZhi Qiang Si
Zhi Qiang Si
LLLong Li
Long Li
As critical components of mechanical equipment, the health condition of bearings directly determines the stable operation and operational safety of machinery. Thus, timely early fault diagnosis of bearings is of great practical significance. Nevertheless, collected vibration signals are frequently contaminated by strong ambient noise, which hinders effective extraction of discriminative fault features and degrades diagnosis accuracy. To tackle this problem, this paper proposes a multi-scale noise-robust residual network built with dilated structures to boost diagnosis accuracy under high-noise environments. Specifically, stacked dilated convolutions are embedded inside residual bottleneck blocks to enlarge the receptive field of shallow networks during fault feature extraction, and dimensionality reduction operations are adopted to suppress noise interference. Stacked such dilated residual blocks are assembled to construct a dedicated noise-robust module named DRes-Block. Furthermore, a channel attention module is deployed after the noise-robust module to strengthen the weight responses of feature channels highly correlated with faults, which further improves the anti-noise capability of the module. To fully capture comprehensive fault features, a multi-scale feature extraction module is designed, which adopts distinct dilation rates on parallel branches to mine multi-scale inherent characteristics of fault vibration signals. This module is integrated to construct an end-to-end bearing fault diagnosis model, namely DResB-MDCNN. Experimental results demonstrate that the proposed model achieves diagnosis accuracy higher than 95% under strong noise with an SNR of −8 dB on both the CWRU bearing dataset and self-simulated bearing dataset. Even under the extreme noise condition of SNR = − 10 dB, the model still reaches an accuracy of 87.07%, outperforming ResNet18, VGG16, CNN-TCN and WDCNN-BiGRU by 2.53%, 29.45%, 4.95% and 11.93% respectively. Based on the data sampling and partitioning strategy proposed in this paper and the experimental platform used, each training epoch only takes 3.4 s. The total number of trainable parameters of the model is 2326 438, with a storage size of approximately 8.87 MB, which renders the model lightweight. Therefore, the DResB-MDCNN model proposed in this paper possesses prominent comprehensive advantages for bearing fault diagnosis under heavy noise interference.

30 October 2026 in Engineering Research Express
Verified
Journal Article
Closed access
YZYingyong Zou
Yingyong Zou
ZSZhi Qiang Si
Zhi Qiang Si
CLChun Fang Li
Chun Fang Li
YZYu Zhang
Yu Zhang
LLLong Li
Long Li
Bearings are a vital component of rotating machinery, and their operating condition directly affects the stable operation of the equipment. However, due to changes in operating conditions, the diagnostic accuracy of traditional models fluctuates, and they are unable to adapt quickly to new operating conditions. Consequently, a diagnostic method has been devised for variable speeds and variable loads, with the aim of improving efficiency whilst maintaining high diagnostic accuracy. Specifically, the maximum mean difference is used to reduce the feature distance between the two operating conditions, whilst domain-adversarial and featureextraction modules are constructed to extract domain-invariant features. This method of aligning first and then extracting reduces the number of ineffective adversaries in adversarial training, thereby improving diagnostic speed. On the other hand, domain adversarial learning improves diagnostic accuracy under varying loads by extracting generalized features. The experimental results show that diagnostic accuracy exceeded 98% for both the CWRU dataset and simulated data. Ablation experiments have demonstrated the superiority of feature alignment followed by domain-invariant feature extraction. Using this platform and the data scale and partitioning methods employed in this study, a single training run takes approximately 11 seconds. This study achieved optimal diagnostic accuracy after just 30 training rounds; meanwhile, the model's total parameter size is 13.12 MB, occupying approximately 0.4 GB of video memory, making it suitable for deployment on small platforms. Consequently, this study is better suited to bearing fault diagnosis.