2 May 2018 in IEEE Journal of Translational Engineering in Health and Medicine
High-dosage motor practice can significantly contribute to achieving functional recovery after a stroke. Performing rehabilitation exercises at home and using, or attempting to use, the stroke-affected upper limb during Activities of Daily Living (ADL) are effective ways to achieve high-dosage motor practice in stroke survivors. This paper presents a novel technological approach that enables 1) detecting goal-directed upper limb movements during the performance of ADL, so that timely feedback can be provided to encourage the use of the affected limb, and 2) assessing the quality of motor performance during in-home rehabilitation exercises so that appropriate feedback can be generated to promote high-quality exercise. The results herein presented show that it is possible to detect 1) goal-directed movements during the performance of ADL with a c-statistic of 87.0% and 2) poorly performed movements in selected rehabilitation exercises with an F-score of 84.3%, thus enabling the generation of appropriate feedback. In a survey to gather preliminary data concerning the clinical adequacy of the proposed approach, 91.7% of occupational therapists demonstrated willingness to use it in their practice, and 88.2% of stroke survivors indicated that they would use it if recommended by their therapist.
9 December 2016 in Epilepsia
Summary: Objectives: Interictal epileptiform discharges (IEDs) have been linked to memory impairment, but the spatial and temporal dynamics of this relationship remain elusive. In the present study, we aim to systematically characterize the brain areas and times at which IEDs affect memory.Methods: Eighty epilepsy patients participated in a delayed free recall task while undergoing intracranial electroencephalography (EEG) monitoring. We analyzed the locations and timing of IEDs relative to the behavioral data in order to measure their effects on memory.Results: Overall IED rates did not correlate with task performance across subjects (r = 0.03, p = 0.8). However, at a finer temporal scale, within‐subject memory was negatively affected by IEDs during the encoding and recall periods of the task but not during the rest and distractor periods (p < 0.01, p < 0.001, p = 0.3, and p = 0.8, respectively). The effects of IEDs during encoding and recall were stronger in the left hemisphere than in the right (p < 0.05). Of six brain areas analyzed, IEDs in the inferior‐temporal, medial‐temporal, and parietal areas significantly affected memory (false discovery rate < 0.05).Significance: These findings reveal a network of brain areas sensitive to IEDs with key nodes in temporal as well as parietal lobes. They also demonstrate the time‐dependent effects of IEDs in this network on memory.
7 January 2019 in IEEE Robotics and Automation Letters
Over the past several decades, as affordable computational power has increased, simulation has become increasingly important in robot analysis, planning, and control. Smooth robot dynamics can be simulated efficiently and accurately and therefore readily used in model-based control schemes. However, some of the most difficult and important problems in robotics, such as running, grasping, and parts assembly, involve intermittent frictional contacts, which introduce extreme nonlinearities into the dynamics. Numerous approaches have been developed to simulate contact dynamics. Even though real bodies are not rigid, idealized rigid contact models have been used widely and productively for decades. However, the resulting non-smooth dynamics can be computationally difficult to solve or use in model-based planning and control, motivating researchers to propose various relaxations of the idealized contact models. The varied origins and formulations of these approaches can obscure their similarities and differences. In this paper, we identify and explain differences between four contact models. We present the models in the context of one solver that is applicable to all of them, namely Projected Gauss-Seidel, in order to highlight their common structure and to avoid confounding their comparison with differences in the solution methods. Simulation results from sliding, wedging, grasping, and stacking experiments illustrate consequences of the differences. The results can help inform roboticists when comparing and selecting models for their specific applications.
1 April 2016 in Review of Scientific Instruments
The interpretation of planar retarding potential analyzers (RPA) during ionospheric sounding rocket missions requires modeling the thick 3D plasma sheath. This paper overviews the theory of RPAs with an emphasis placed on the impact of the sheath on current-voltage (I-V) curves. It then describes the Petite Ion Probe (PIP) which has been designed to function in this difficult regime. The data analysis procedure for this instrument is discussed in detail. Data analysis begins by modeling the sheath with the Spacecraft Plasma Interaction System (SPIS), a particle-in-cell code. Test particles are traced through the sheath and detector to determine the detector’s response. A training set is constructed from these simulated curves for a support vector regression analysis which relates the properties of the I-V curve to the properties of the plasma. The first in situ use of the PIPs occurred during the MICA sounding rocket mission which launched from Poker Flat, Alaska in February of 2012. These data are presented as a case study, providing valuable cross-instrument comparisons. A heritage top-hat thermal ion electrostatic analyzer, called the HT, and a multi-needle Langmuir probe have been used to validate both the PIPs and the data analysis method. Compared to the HT, the PIP ion temperature measurements agree with a root-mean-square error of 0.023 eV. These two instruments agree on the parallel-to-B plasma flow velocity with a root-mean-square error of 130 m/s. The PIP with its field of view aligned perpendicular-to-B provided a density measurement with an 11% error compared to the multi-needle Langmuir Probe. Higher error in the other PIP’s density measurement is likely due to simplifications in the SPIS model geometry.