Background and Purpose: Walking speed is associated with several health-related outcomes. Research examining how differences in test walking distance affect walking speed reliability and validity is limited. The primary purpose of this study was to examine the reliability and concurrent validity of gait speed measurements obtained from a 4-Meter Walk Test compared with the commonly used 10-Meter Walk Test. A second objective was to similarly examine 2 different timing methods: stopwatch and automatic timers. Methods: Forty-three healthy, older adults (mean age = 84.3 ± 6.9 years) performed 3 consecutive walking trials on the 4- and 10-Meter Walk Tests at their self-selected walking speed. Results: Gait speed measurements for both tests were shown to have excellent test-retest reliability (ICC values of 0.96–0.98), with similar results for stopwatch and automatic timer assessments (ICC values of 0.99–1.00). Standard error of the measurement (SEM) values were small (0.004–0.008 m/s) across measurement methods. While the ICC value for gait speed measurements between the 2 walk tests was 0.93, the Bland-Altman analysis revealed a discrepancy of ±0.15 to ±0.17 m/s between measurement methods. Discussion: Both 4- and 10-m gait speed assessments had excellent test-retest reliability with similar SEM and minimal detectable change values. There was little difference in SEM values between the 2 timing methods. While the mean difference in gait speed between the 4- and 10-Meter Walk Tests was small, the range of the measurement differences was large enough to potentially mask meaningful changes in gait speed over time if both methods were used interchangeably. Conclusions: While the reliability of both walking tests is excellent, the 4-Meter Walk Test does not exhibit a high enough degree of concurrent validity with the 10-Meter Walk Test to be used interchangeably for gait speed assessments in healthy, older adults. We therefore recommend using the 10-Meter Walk Test to obtain the most valid clinical assessment of walking speed when using it as a 1-time indicator of health status.
1 September 2013 in Journal of Neurologic Physical Therapy
The use of video gaming as a therapeutic intervention has increased in popularity; however, the number of repetitions in comparison with traditional therapy methods has yet to be investigated. The primary purpose of this study was to document and compare the number of repetitions performed while playing 1 of 2 video gaming systems for a time frame similar to that of a traditional therapy session in individuals with chronic stroke. Twelve participants with chronic stroke (mean age, 66.8 ± 8.2 years; time poststroke, 19.2 ± 15.4 months) completed video game play sessions, using either the Nintendo Wii or the Playstation 2 EyeToy. A total of 203 sessions were captured on video record; of these, 50 sessions for each gaming system were randomly selected for analysis. For each selected record, active upper and lower extremity repetitions were counted for a 36-minute segment of the recorded session. The Playstation 2 EyeToy group produced an average of 302.5 (228.1) upper extremity active movements and 189.3 (98.3) weight shifts, significantly higher than the Nintendo Wii group, which produced an average of 61.9 (65.7) upper extremity active movements and 109.7 (78.5) weight shifts. No significant differences were found in steps and other lower extremity active movements between the 2 systems. The Playstation 2 EyeToy group produced more upper extremity active movements and weight shifting movements than the Nintendo Wii group; the number and type of repetitions varied across games. Active gaming (specifically Playstation 2 EyeToy) provided more upper extremity repetitions than those reported in the literature by using traditional therapy, suggesting that it may be a modality to promote increased active movements in individuals poststroke.
1 November 2011 in Archives of Physical Medicine and Rehabilitation