Wayne M. Itano

Wayne M. Itano

Auto-generated profile, based on publicly available information

Wayne M. Itano

Time and Frequency Division National Institute of Standards and Technology 80305 Boulder Colorado

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2000 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
WIW.M. Itano
W.M. Itano
Frequency shifts of the (199)Hg(+) 5d (10)6s (2)S1/2 (F = 0, MF = 0) to 5d (9)6s (2 2)D5/2 (F = 2, MF = 0) electric-quadrupole transition at 282 nm due to external fields are calculated, based on a combination of measured atomic parameters and ab initio calculations. This transition is under investigation as an optical frequency standard. The perturbations calculated are the quadratic Zeeman shift, the scalar and tensor quadratic Stark shifts, and the interaction between an external electric field gradient and the atomic quadrupole moment. The quadrupole shift is likely to be the most difficult to evaluate in a frequency standard and may have a magnitude of about 1 Hz for a single ion in a Paul trap.

1 November 1990 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
DWD.J. Wineland
D.J. Wineland
JBJ.C. Bergquist
J.C. Bergquist
JBJ.J. Bollinger
J.J. Bollinger
WIW.M. Itano
W.M. Itano
DHD.J. Heinzen
D.J. Heinzen
MRM.G. Raizen
M.G. Raizen
Experiments directed toward the realization of frequency standards of high accuracy using stored ions are briefly summarized. In one experiment, an RF oscillator is locked to a nuclear spin-flip hyperfine transition (frequency approximately= 3.03*10/sup 8/ Hz) in /sup 9/Be/sup +/ ions that are stored in a Penning trap and sympathetically laser-cooled. Stability is better than 3*10/sup -12/ tau /sup -(1/2)/ and uncertainty in Doppler shifts is estimated to be less than 5*10/sup -15/. In a second experiment, a stable laser is used to probe an electric quadrupole transition (frequency approximately=1.07*10/sup 15/ Hz) in a single laser-cooled /sup 199/Hg/sup +/ ion stored in a Paul trap. The measured Q value of this transition is approximately 10/sup 13/. Future possible experiments are discussed.<>

22 July 2011 in Physical Review A
Verified
Journal Article
Closed access
NSNobuyasu Shiga
Nobuyasu Shiga
WIW. M. Itano
W. M. Itano
JBJ. J. Bollinger
J. J. Bollinger
We report an experimental determination of the diamagnetic correction to the 9Be+ ground state hyperfine constant A. We measured A = $-${}625008837.371(11) Hz at a magnetic field B of 4.4609 T. Comparison with previous results, obtained at lower values of B (0.68 T and 0.82 T), yields the diamagnetic shift coefficient k = 2.63(18)\ifmmode\times\else\texttimes\fi{}10$-${}11 T$-${}2, where A(B)=A0(1+kB2). The zero-field hyperfine constant A0 is determined to be $-${}625008837.044(12) Hz. The g-factor ratio gI$'${}/gJ is determined to be 2.1347798527(10)\ifmmode\times\else\texttimes\fi{}10$-${}4, which is equal to the value measured at lower B to within experimental error. Upper limits are placed on some other corrections to the Breit-Rabi formula. The measured value of k agrees with theoretical estimates.

1 January 2000 in Physics of Plasmas
Verified
Journal Article
Closed access
JBJ. J. Bollinger
J. J. Bollinger
TMT. B. Mitchell
T. B. Mitchell
XHX.-P. Huang
X.-P. Huang
WIW. M. Itano
W. M. Itano
JTJ. N. Tan
J. N. Tan
DWD. J. Wineland
D. J. Wineland
Laser-cooled trapped ions can be strongly coupled and form crystalline states. In this paper we review experimental studies that measure the spatial correlations of Be+ ion crystals formed in Penning traps. Both Bragg scattering of the cooling-laser light and spatial imaging of the laser-induced ion fluorescence are used to measure these correlations. In spherical plasmas with more than 2×105 ions, body-centered-cubic (bcc) crystals, the predicted bulk structure, are the only type of crystals observed. The orientation of the ion crystals can be phase locked to a rotating electric-field perturbation. With this “rotating wall” technique and stroboscopic detection, images of individual ions in a Penning trap are obtained. The rotating wall technique also provides a precise control of the time-dilation shift due to the plasma rotation, which is important for Penning trap frequency standards.

1 January 2001 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
DSD.B. Sullivan
D.B. Sullivan
JBJ.C. Bergquist
J.C. Bergquist
JBJ.J. Bollinger
J.J. Bollinger
RDR.E. Drullinger
R.E. Drullinger
WIW.M. Itano
W.M. Itano
DWD.J. Wineland
D.J. Wineland
The development of atomic frequency standards at NIST is discussed and three of the key frequency-standard technologies of the current era are described. For each of these technologies, the most recent NIST implementation of the particular type of standard is described in greater detail. The best relative standard uncertainty achieved to date for a NIST frequency standard is 1.5×10(-15). The uncertainties of the most recent NIST standards are displayed relative to the uncertainties of atomic frequency standards of several other countries.