Parag B. Sahasrabudhe

Parag B. Sahasrabudhe

Auto-generated profile, based on publicly available information

Parag B. Sahasrabudhe

Department of Plastic & Reconstructive Surgery, Byramjee Jeejeebhoy Government Medical College, Pune, Maharashtra, India

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2025 in Indian Journal of Plastic Surgery
Verified
Journal Article
Open access
PDF file
AMAditya B. Marathe
Aditya B. Marathe
PBPiyush V. Bamnodkar
Piyush V. Bamnodkar
AKAnkur S. Karanjkar
Ankur S. Karanjkar
PSParag B. Sahasrabudhe
Parag B. Sahasrabudhe
NPNikhil S. Panse
Nikhil S. Panse
Work-related musculoskeletal disorders (WRMDs) are a less discussed entity in the medical profession, with surgical specialties being more prone to them. Little is known about these types of injuries in plastic surgeons specifically. Data on WRMDs among Indian plastic surgeons are lacking. The goals of this study were to evaluate the prevalence, nature, particular contributory causal factors and behaviors, and potential remedies of these musculoskeletal injuries among plastic surgeons in India.An online voluntary survey was conducted among plastic surgeons in India, collecting their demographics, workload characteristics, musculoskeletal issues, causal factors, and corrective measures, taken using Google Forms. Data were extracted into an MS Excel spreadsheet and analyzed. The prevalence of WRMDs was calculated and the predictors were evaluated with a univariate analysis.Thirty-three percent of 297 respondents had work-related musculoskeletal injuries or disorders, with the majority experiencing pain (82%), with the neck being the most common site (61%); this was followed by stiffness (61%) and fatigue (52%). The most common causative factors were sustained posture (81%), awkward posture (72%), and inadequate breaks (34%). Age (p = 0.041) and average operative hours per week (p = 0.036) were found to be statistically significant (p < 0.05). The corrective measures cited were stretching exercises, core-strengthening exercises, maintaining proper posture, taking frequent breaks, and yoga.Plastic surgeons are at high risk of WRMDs, with a significant prevalence in India. Albeit plastic surgeons in India face a higher case load, implementation of ergonomic principles can help in reducing the incidence of these disorders and in preventing the severity of sequelae.

18 March 2024 in Indian Journal of Plastic Surgery
Verified
Journal Article
Open access
PDF file
SRSwaminathan Ravi
Swaminathan Ravi
PSParag Sahasrabudhe
Parag Sahasrabudhe
AKAnkur Karanjkar
Ankur Karanjkar
AIAvinash Ignatius
Avinash Ignatius
SKSaurabh Khiste
Saurabh Khiste
Respected Sir, The burden of chronic kidney disease requiring hemodialysis in India has been estimated to be 175,000 patients with a prevalence of 129 per million population.[1] We would like to report this interesting anatomical anomaly encountered at our center of a septated cephalic vein proximal to the cubital crease along with our technique of managing the same. We did an extensive literature search and could not find any such anomaly reported during arteriovenous fistula (AVF) creation. Knowledge of the existence of such an anomaly and how to successfully create an AVF and protect an access site will be advantageous. A 57-year-old male diagnosed with end-stage renal disease (ESRD) and on maintenance hemodialysis via temporary dialysis catheter was referred to us for the creation of an AVF. On evaluation clinically and on preoperative ultrasound Doppler the cephalic vein was diminutive at the wrist with a diameter of less than 2 mm that led to us choosing to create an end-to-side brachiocephalic AVF. The report did not mention the existence of any luminal septum. Intraoperatively, on dividing the cephalic vein distally at the cubital crease, a vertical septum was noted in the lumen. On trimming the vein proximally, the septum was noted to extend up to a distance of approximately 3 cm proximal to the cubital crease ([Fig. 1]). A line drawing of the same is depicted ([Fig. 2]). Heparinized saline was flushed through both lumens and a thrill was palpable proximally over the vein. An end-to-side anastomosis was done using 7–0 Polypropylene suture incorporating the posterior wall of the arteriotomy with the posterior wall of the cephalic vein and the septum while the anterior wall was completed by approximating the anterior walls of the artery and vein, thus obliterating the smaller lumen ([Fig. 3]). Hemostasis was achieved after removal of the clamps and a palpable thrill was noted in the arm along with an audible bruit. The vein was well dilated with adequate arterial flow. A ultrasound Doppler was repeated postoperatively that showed a septum in the cephalic vein extending proximally for a distance of 2.6 cm from the site of anastomosis. A similar septum was noted in the right cephalic vein from the confluence of the forearm veins running into the arm with healthy color flow noted in both lumens ([Fig. 4]). The patient successfully underwent hemodialysis by cannulation of the matured AVF after 6 weeks with adequate flow velocity in the cephalic vein. Most AVF are created under local anesthesia with relatively smaller access incisions and encountering such an anomaly intraoperatively limits our option to trim the vein proximally and perform a higher anastomosis. Each AVF site for ESRD patients is precious and needs to be carefully used and preserved. In this patient, we have proposed a method of anastomosis to one of the lumens while simultaneously closing the other lumen with the suture, which led to successful maturation and use of the vein for hemodialysis. Article published online: 18 March 2024 © 2024. Association of Plastic Surgeons of India. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India