Fatih Kaya

Fatih Kaya

Auto-generated profile, based on publicly available information

Fatih Kaya

Burdur Mehmet Akif Ersoy Üniversitesi

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2021 in Mühendislik Bilimleri ve Tasarım Dergisi
Verified
Journal Article
Closed access
PDF file
FKFatih Kaya
Fatih Kaya
GIGulhan Ince
Gulhan Ince
MAMehmet Avcar
Mehmet Avcar
LYLokman Yünlü
Lokman Yünlü
Total kalça protezi tasarımında protez performansı ve kullanım ömrünün artırılmasına yönelik çalışmalar gelişen cerrahi yöntemlerin yanı sıra malzeme ve üretim teknolojileriyle beraber son yıllarda oldukça hız kazanmıştır. Değişen ve gelişen biyomedikal teknolojisine her geçen gün ayak uydurabilen pratik yapısal ve mekanik çözümler günümüz mühendislik biliminin temel sorunlarından biri haline gelmiştir. Bu nedenle bilim insanlarının ilgi odağı, farklı malzemelerden yapılmış yapısal ve mekanik bileşenlerin farklı davranışlarına ilişkin analitik, sayısal ve deneysel çalışmalar olmuştur. Sonlu elemanlar yöntemi yeni protez tasarımlarının dayanım performansları hakkında prototip üretimi ve fiziksel testler yapılmaksızın gerçeğe oldukça yakın önemli bilgiler sağlamaktadır. Sunulan çalışmada kalça protezlerinde yaygın olarak kullanılan Ti-6Al-4V malzemesi kullanılarak ASTM F2996-20 kalça protezi sapı modeli üzerinde sonlu elemanlar yöntemi ile statik analiz yapılarak protezin performansı incelenmiştir. Ayrıca mesh tipi ve eleman boyutunun gerilme ve birim şekil değiştirmeler üzerindeki etkileri nümerik olarak ANSYS 19 paket programı kullanılarak ele alınmıştır. Elde edilen sonuçlardan, eleman boyutunun 1mm’den küçük olması durumunda, gerilme ve birim şekil değiştirmeler üzerinde etkisi olmadığını fakat işlem süresini oldukça arttırarak çözümü ekonomiklikten uzaklaştırdığı görülmüştür.

26 October 2024 in International Journal of Engineering and Innovative Research
Verified
Journal Article
Open access
FKFatih Kaya
Fatih Kaya
GIGulhan Ince
Gulhan Ince
This study used Finite Element Analysis (FEA) and Reverse Engineering (RE) methods to assess the fatigue performance of an originally designed cementless hip implant. The implant prototype was initially scanned using 3D scanning technology, and a finite element model was created. The implant was analyzed under dynamic loads for six different biomaterials commonly used, namely Ti-6Al-4V (Grade5), ASTM F3046 (Ti-3Al-2.5V), ASTM F75 (CoCr), ASTM F562(MP35N), ASTM F136(Ti6Al4V ELI), ASTM F67 (Ti Grade 4), and the fatigue life was evaluated. The results showed that the ASTM F75 (CoCr) implant had the highest stress and the ASTM F67 (Ti Grade 4) implant had the lowest stress. Also, Ti6Al4V (Grade 5) implant is more resistant to fatigue than their counterparts made from ASTM F75 (CoCr), ASTM F136 (Ti6Al4V ELI) and ASTM 3046 (Ti-3Al-2.5V).

27 June 2022
Verified
Preprint
Open access
PDF file
FKFatih Kaya
Fatih Kaya
GIGülhan İnce
Gülhan İnce
Fatigue life estimation is one of the vital factors in the design of biomedical prostheses. But fatigue tests of a hip prosthesis require over ten million cycles, furthermore experimental methods may be too expensive and take a long time for material selection or optimization. Therefore, numerical analyses performed by Finite Elements Methods (FEM) becomes necessary to pre-estimation of fatigue life. In this study, a numerical analysis performed by FEM analysis to estimate the fatigue performance of newly designed hip prosthesis. Prior to experimental testing processes, aimed to analyze the candidate designs and to contribute to complete of the verification process in a more efficient, economical, and fast manner.