28 May 2018 in Bulletin of Earthquake Engineering
1 October 2021 in Structures
17 May 2021 in European Journal of Environmental and Civil Engineering
The seismic retrofit of existing reinforced concrete (RC) beam-column joints in the case of the interior reinforcement of deformed bars and plain bars, as well as the decision regarding convenient retrofit strategies in the joints panel, are of major interest throughout the seismically active areas of the world. The efficiency of the proposed retrofit method called ‘joint enlargement’ in RC exterior and interior beam-column joints reinforced with deformed and plain bars, which have been performed under two different experimental setups in same university laboratories, is investigated. Seven half-scale beam-column joint reinforced by plain bars and four half-scale beam-column joint reinforced by deformed bars were tested. All specimens were subjected to a cyclic quasi-static loading to observe different levels of structural damage. The tested specimens comprised of five control specimens and six retrofitted specimens with various reinforcement detailing and varying dimensions of joint enlargement. The test results show significant improvement of the retrofitted specimens of both deformed and plain bars in terms of protecting the joint region, showing more ductile response and higher hysteresis energy capacity. The ultimate lateral load capacity was increased for all retrofitted specimens. The tests also show that the retrofit strategy for specimens reinforced with plain bars was performed well. Accordingly, the proposed retrofit strategy may be recommended for similar cases in existing old buildings reinforced with plain or deformed bars.
1 January 2020 in Cogent Engineering
Addition of the waste tire rubber powder to the cement-based products is a solution for the waste problems and protecting environment. Cement-sand mortar is an integral part of masonry buildings and has an important effect on the integrity of the masonry walls. In the current research, mechanical properties and microstructures of the rubberized mortar have been investigated over various lifetimes and the cement content of the mortar was optimized by Pareto solutions. Portland composite cement (PCC) was used for making the rubberized mortar. The amount of rubber additive to the mortar specimens is considered to be 5%. The cement and water content were the variable parameters in the mixture designs while the ratio of W/C was fixed and equalled to 0.6. The microstructure analysis of the test specimens showed that the adherence of the rubber powder particles in the mortar mixture would be more effective with increasing of the cement content, and the negative effects of using rubber powder on the mortar structure can be minimized by choosing the appropriate mixture design. Also, it shows that by increasing the amount of cement in the mixture design of rubberized mortar, the compressive, tensile and flexural strengths of the mortar would be very close to the plain mortar specimens, and in some cases, the tensile and flexural strength of the mortar specimens would be increased regarding the plain mortar specimens.
23 December 2020 in European Journal of Environmental and Civil Engineering
Concrete buildings reinforced by plain bars are one of the special types of old structures generally built before the 1970s. According to the experiences of earthquakes and experimental tests, the dominant damage mode in these structures includes a deep crack at the intersection of the beam with the joint panel zone. In this study, seismic fragility curves of existing concrete buildings reinforced by plain bars were investigated by means of incremental dynamic analysis and by consideration of soil-type effects and construction quality effects. A relatively simple and efficient non-linear model based on the experimental behaviour of exterior and interior joints of the represented building is used to simulate pre- and post-elastic behaviour of the joints which fail under bar slippage mode. Two record sets were considered corresponding to the soil types C and D of the NEHRP provision. The results indicated that the seismic vulnerability of the represented building increases at all damage states as the type of soil changes from C to D. On average, the median capacity of the building is decreased by about 30% for the moderate limit state as the type of soil changes from C to D. Also, the normal distribution function with median data is the best distribution function for seismic fragility assessment of the represented building.
29 July 2026 in Soil Dynamics and Earthquake Engineering