Ruili Wu

Ruili Wu

Auto-generated profile, based on publicly available information

Ruili Wu

Henan University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2017 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
YLYanbing Lv
Yanbing Lv
RWRuili Wu
Ruili Wu
KFKunrui Feng
Kunrui Feng
JLJinjie Li
Jinjie Li
QMQing Mao
Qing Mao
LLLin Song Li
Lin Song Li
The conventional and widely used enzyme-linked immunosorbent assays (ELISA), due to specificity and high-sensitivity, were suitable in vitro diagnosis. But enzymes are vulnerable to the external conditions, and the complex operation steps limit its application. Semiconductor quantum dots have been successfully used in biological and medical research due to the high photoluminescence and high resistance to photobleaching. In this study, we have developed a novel quantum dot-labeled immunosorbent assay for rapid disease detection of C-reactive protein (CRP). The assay for the detection of CRP can provide a wide analytical range of 1.56–400 ng/mL with the limit of detection (LOD) = 0.46 ng/mL and the limit of quantification = 1.53 ng/mL. The precision of the assay has been confirmed for low coefficient of variation, less than 10% (intra-assay) and less than 15% (inter-assay). The accuracy of assay meets the requirements with the recoveries of 95.4–105.7%. Furthermore, clinical samples have been collected and used for correlation analysis between this FLISA and gold standard Roche immunoturbidimetry. It shows excellent accurate concordance and the correlation coefficient value (R) is as high as 0.989 (n = 34). This in vitro quantum dot-based detection method offers a lower LOD and a wide liner detection range than ELISA. The total reaction time is only 50 min, which is much shorter than the commercialization ELISA (about 120 min). All of the results show that a convenient, sensitive, and accurate fluorescence-linked immunosorbent assay method has been well established for the detection of CRP samples. Therefore, this method has immense potential for the development of rapid and cost-effective in vitro diagnostic kits.

1 October 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JLJinjie Li
Jinjie Li
YLYanbing Lv
Yanbing Lv
NLNing Li
Ning Li
RWRuili Wu
Ruili Wu
JLJiangnan Li
Jiangnan Li
LLLin Song Li
Lin Song Li

13 April 2021 in Inorganic Chemistry
Verified
Journal Article
Open access
YXYanxia Xu
Yanxia Xu
YLYanbing Lv
Yanbing Lv
RWRuili Wu
Ruili Wu
JLJinjie Li
Jinjie Li
HSHuaibin Shen
Huaibin Shen
LLLin Song Li
Lin Song Li
Low-toxic InP quantum dots (QDs) as an ideal candidate for Cd-based QDs have tremendous potential for next-generation commercial display and biological detection applications. However, the progress in biological detection is still far behind that of the Cd-based QDs. This is mainly because the InP-based QDs are of inferior stability and photoluminescence quantum yield (PL QY) in aqueous solution. Here, PL QY of 65% and excellent stability of InP/GaP/ZnS [email protected]2 nanoparticles have been successfully synthesized via a silica coating method. The containing thiol-capped hydrophobic InP/GaP/ZnS QDs were pre-silanized with waterless, ammonia-free hydrolysis tetraethyl orthosilicate, and subsequently, an outer silica shell was generated in the reverse microemulsion. The corresponding QD-based fluorescence-linked immunosorbent assay exhibits a high sensitivity of 0.9 ng mL–1 for C-reactive protein and the broad detection range of 1–1000 ng mL–1, which was close to that of the state-of-the-art Cd-based [email protected]2 nanoparticles and had the highest sensitivity of Cd-free QDs so far. This work provides a very successful silica coating method for the containing thiol-capped hydrophobic QDs and the QDs highly sensitive to water and oxygen, and the obtained InP/GaP/ZnS [email protected]2 nanoparticles were considered as the robust, biocompatible, and promising Cd-free fluorescent labels for the further ultra-sensitive detection.

15 February 2023 in Nanoscale
Verified
Journal Article
Closed access
PDF file
YLYanbing Lv
Yanbing Lv
JFJinjin Fan
Jinjin Fan
MZMan Zhao
Man Zhao
RWRuili Wu
Ruili Wu
LLLin Song Li
Lin Song Li
Quantum dot-based fluorescence-linked immunosorbent assays (QD-FLISAs) have been greatly developed in the field of in vitro diagnostics (IVD) and food safety due to their advantages of high sensitivity, high precision and high throughput.

4 September 2024 in Nano Research
Verified
Journal Article
Closed access
PDF file
YLYanbing Lv
Yanbing Lv
LZLifang Zhang
Lifang Zhang
RWRuili Wu
Ruili Wu
LLLin Song Li
Lin Song Li
Semiconductor quantum dots (QDs), as promising fluorescent materials, have been widely applied in biomedical application due to their unique optical properties. Currently, the most intensively studied are Cd-containing QDs (Cd-based QDs), whose potential toxicity prevents their further commercialization. In recent years, the eco-friendly QDs with low toxicity and environmental friendliness have begun to be developed, showing great potential in biomedical applications. The high-quality synthesis of eco-friendly QDs and the appropriate surface modification are key to realize their applications. This review summarizes the progress of eco-friendly QDs for biomedical applications, including their designed preparation, optical properties, surface modification, toxicity, and their applications in bioimaging and diagnostics. Finally, the challenges of eco-friendly QDs for future bioimaging and diagnostics application were provided. We believe this review will provide important guidance for promoting the development of eco-friendly QDs in bioimaging and diagnostics.

10 March 2021 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
YLYanbing Lv
Yanbing Lv
YYYucheng Yuan
Yucheng Yuan
NHNing Hu
Ning Hu
NJNa Jin
Na Jin
DXDangdang Xu
Dangdang Xu
LLLin Song Li
Lin Song Li