Samantha Michelle Gateman

Samantha Michelle Gateman

Auto-generated profile, based on publicly available information

Samantha Michelle Gateman

Western University

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2024 in Analytical Chemistry
Verified
Journal Article
Closed access
EMEmmanuel Mena-Morcillo
Emmanuel Mena-Morcillo
APAli Ebrahimzadeh Pilehrood
Ali Ebrahimzadeh Pilehrood
RMReza Moshrefi
Reza Moshrefi
GSGhazal Shafiee
Ghazal Shafiee
PKPeter George Keech
Peter George Keech
SGSamantha Michelle Gateman
Samantha Michelle Gateman

3 August 2023 in Electrochemical Science Advances
Verified
Journal Article
Open access
SSSebastian Amland Skaanvik
Sebastian Amland Skaanvik
SGSamantha Michelle Gateman
Samantha Michelle Gateman
Passive films are essential for the longevity of metals and alloys in corrosive environments. A great deal of research has been devoted to understanding and characterizing passive films, including their chemical composition, uniformity, thickness, porosity, and conductivity. Many characterization techniques are conducted under vacuum, which do not portray the true in‐service environments passive films will endure. Scanning electrochemical probe microscopy (SEPM) techniques have emerged as necessary tools to complement research on characterizing passive films to enable the in situ extraction of passive film parameters and monitoring of local breakdown events of compromised films. Herein, we review the current research efforts using scanning electrochemical microscopy, scanning electrochemical cell microscopy (or droplet cell measurements), and local electrochemical impedance spectroscopy techniques to advance the knowledge of local properties of passivated metals. The future use of SEPM for quantitative extraction of local film characteristics within in‐service environments (i.e., with varying pH, solution composition, and applied potential) is promising, which can be correlated to nanostructural and microstructural features of the passive film and underlying metal using complementary microscopy and spectroscopy methods. The outlook on this topic is highlighted, including exciting avenues and challenges of these methods in characterizing advanced alloy systems and protective surface films.

4 October 2024 in ACS Measurement Science Au
Verified
Journal Article
Open access
NSNishtha Saxena
Nishtha Saxena
EMEmmanuel Mena-Morcillo
Emmanuel Mena-Morcillo
MTMia Tripp
Mia Tripp
PKPeter George Keech
Peter George Keech
MBMehran Behazin
Mehran Behazin
SGSamantha Michelle Gateman
Samantha Michelle Gateman
This work presents a new methodology to estimate the surface area of the working electrode during scanning electrochemical cell microscopy (SECCM) in situ by utilizing retraction curves. In this approach, the current is measured as a function of pipet displacement in the z-direction. When the current drops to zero, it is indicative of droplet detachment from the surface, allowing for the estimation of the droplet contact diameter based on the pipet displacement. This enables real-time estimations of surface areas of the wetted electrode at each point of measurement, rather than performing time-consuming measurements using ex situ correlative image analysis or estimating an average working electrode size from the pipet aperture. Notably, during SECCM measurements on copper in nitric acid, the working electrode diameter estimated using retraction curves was significantly smaller than the droplet footprint diameter observed post experiment using ex situ correlative image analysis. This discrepancy is attributed to droplet spreading after pipet retraction, as confirmed by goniometer and silanized pipet measurements. Upon cleaning the surface, the true wetted surface areas during SECCM measurements were found to be in good agreement with values estimated using retraction curves yet were larger than the pipet aperture. Additionally, the effects of approach separation, retraction rates, and probe diameter on the droplet contact size were analyzed using retraction curves. These findings were compared to ex situ methods to assess the reliability of the retraction curves for determining the working electrode surface area. This study demonstrates the potential of retraction curves to provide a higher accuracy in the quantitative analysis of local current density values extracted using SECCM.

30 November 2024 in Electrochimica Acta
Verified
Journal Article
Open access
GSGhazal Shafiee
Ghazal Shafiee
MTMia Tripp
Mia Tripp
JHJeffrey Daniel Henderson
Jeffrey Daniel Henderson
EMEmmanuel Mena-Morcillo
Emmanuel Mena-Morcillo
MBMehran Behazin
Mehran Behazin
SGSamantha Michelle Gateman
Samantha Michelle Gateman

7 February 2025 in Electroanalysis
Verified
Journal Article
Open access
EMEmmanuel Mena‐Morcillo
Emmanuel Mena‐Morcillo
RMReza Moshrefi
Reza Moshrefi
MBMehran Behazin
Mehran Behazin
PKPeter George Keech
Peter George Keech
SGSamantha Michelle Gateman
Samantha Michelle Gateman
Scanning electrochemical microscopy (SECM) is a popular tool to study corrosion with high spatial resolution. The feedback mode of SECM involves the use of an added redox mediator in solution to probe local surface kinetics. Depending on the redox mediator's oxidation state and formal potential, as well as the corroding metal's corrosion potential, the electroactive species can potentially polarize the substrate and alter the corrosion behavior at the macro and/or microscale. Therefore, the choice of redox mediator is material dependent. This study explored the use of methyl viologen (MV) as a potentially ideal redox mediator for studying the local reactivity of copper. The SECM solutions were deaerated prior to SECM approach curve measurements to avoid a convoluted response from the oxygen reduction reaction at the ultramicroelectrode. Since the formal potential of MV is lower than the corrosion potential of Cu and undergoes oxidation to regenerate at the substrate's surface, the redox mediator was successfully implemented for kinetic measurements without inducing oxidative etching, ultramicroelectrode fouling, or macroscale corrosion. This work highlights the importance of redox mediator choice for SECM corrosion studies to avoid misinterpretation of data and provides a systematic method of making such decision for accurate measurements.

4 July 2024 in npj Women's Health
Verified
Journal Article
Open access
PDF file
JBJacob John Maclean Bunting
Jacob John Maclean Bunting
ZLZuleika Chin Lai Leung
Zuleika Chin Lai Leung
BBBianca Boboc
Bianca Boboc
DBDean Harvey Betts
Dean Harvey Betts
JGJoe B. Gilroy
Joe B. Gilroy
SGSamantha Michelle Gateman
Samantha Michelle Gateman
With over 200 million users worldwide, copper intrauterine devices (Cu-IUDs) are the world’s most popular, non-hormonal, long-acting, and reversible contraception method. Cu-IUDs cause uncomfortable side effects such as longer and heavier menstruation and cramping, all of which persist for the duration of use and often lead to early removal. With the rise in concern about potential physical and psychological side effects from hormonal contraceptive use, an improvement in non-hormonal contraceptive options is needed to alleviate discomforting side effects and inhibit costs. This perspective article provides an overview of the current state of non-hormonal IUDs and experimental factors to consider when developing new materials that have potential as alternative contraceptives, including copper alloys, zinc, iron, and passive metals. It also explores the sustainability and socioeconomic impact of advancing non-hormonal contraceptive options and considers international policy, cultural factors, and costs that must be considered when developing these options. Overall, the article highlights the interdisciplinary nature of this field, the complexities involved in creating effective non-hormonal contraceptives, and the need for innovation and equity in contraceptive care.