The paper presents results of research concerning the basis of utilization of PMSMs in industrial robots. A mathematical model of PMSM is described. Identification of PMSM's parameters is performed as well as an analysis of simulation and experimental investigation results of transients and steady states of electrical and mechanical quantities is presented.
The paper aims to describe a functional radiation shielding door control system as designed and manufactured by the National Centre for Nuclear Research in Otwock, Poland. Basic principles and normative references as well as a short historical overview of control approaches are described.
The article presents a simple way of determining induced voltages in the damping bars of salient pole 5.5 kVA salient pole synchronous generator under no load conditions. Field-circuital model created by coupling FEMM and Matlab environments was used for voltage calculation purposes. The simulation results were verified experimentally in the measurement stand utilizing a purpose built special rotor geometry with additional slip rings connected to individual damping bars.