Todd H. Stievater

Todd H. Stievater

Auto-generated profile, based on publicly available information

Todd H. Stievater

U.S. Naval Research Laboratory

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2002 in Physical Review B
Verified
Journal Article
Closed access
PDF file
JGJeffrey R. Guest
Jeffrey R. Guest
TST. H. Stievater
T. H. Stievater
XLXiaoqin Li
Xiaoqin Li
JCJun Cheng
Jun Cheng
DSD. G. Steel
D. G. Steel
HGH. M. Gibbs
H. M. Gibbs
We have measured the optical absorption due to an exciton confined to a single interface fluctuation quantum dot by directly measuring the transmission through both a submicron aperture and near-field microscopy. The measurements reveal large dipole moments approaching 100 D at 6 K. These results are compared to theoretical predictions based on a physical size estimated from photoluminescence excitation spectroscopy. The very large dipole moment makes these quantum dots attractive candidates for use in microcavities and quantum logic gates.

11 February 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
TSTodd H. Stievater
Todd H. Stievater
MPMarcel W. Pruessner
Marcel W. Pruessner
DPDoewon Park
Doewon Park
WRWilliam S. Rabinovich
William S. Rabinovich
RMR. Andrew McGill
R. Andrew McGill
JKJacob B. Khurgin
Jacob B. Khurgin
We detect trace gases at parts-per-billion levels using evanescent-field absorption spectroscopy in silicon nitride microring resonators coated with a functionalized sorbent polymer. An analysis of the microring resonance line shapes enables a measurement of the differential absorption spectra for a number of vapor-phase analytes. The spectra are obtained at the near-infrared overtone of OH-stretch resonance, which provides information about the toxicity of the analyte vapor.

11 February 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
TSTodd H. Stievater
Todd H. Stievater
RMRita Mahon
Rita Mahon
DPDoewon Park
Doewon Park
WRWilliam S. Rabinovich
William S. Rabinovich
MPMarcel W. Pruessner
Marcel W. Pruessner
CRChristopher J. K. Richardson
Christopher J. K. Richardson
We experimentally demonstrate mid-infrared difference-frequency generation in suspended 181 nm thick GaAs waveguides. Generation of the idler at wavelengths between 2800 and 3150 nm is enabled by form-birefringent phase-matching in ultrahigh index-contrast waveguides. Nonlinear mixing has a measured efficiency of 0.4  W−1 in a 1.2 mm long waveguide using a CW signal tunable between 1490 and 1620 nm and a CW pump tunable between 1018 and 1032 nm at powers of a few mW.

19 November 2002 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
TST. H. Stievater
T. H. Stievater
XLXiaoqin Li
Xiaoqin Li
TCT. Cubel
T. Cubel
DSD. G. Steel
D. G. Steel
DGD. Gammon
D. Gammon
DPD. Park
D. Park
Low temperature relaxation of excitons between polarization eigenstates in single interface fluctuation quantum dots is studied using copolarized and cross-polarized transient differential transmission spectroscopy. The measured spin relaxation times are on the order of ∼100 ps. Such a spin relaxation time is longer than the reported times for thin quantum wells, but considerably shorter than the predicted times for interface fluctuation quantum dots.

1 October 2019 in APL Photonics
Verified
Journal Article
Open access
PDF file
NTN. F. Tyndall
N. F. Tyndall
TST. H. Stievater
T. H. Stievater
DKD. A. Kozak
D. A. Kozak
MPM. W. Pruessner
M. W. Pruessner
WRW. S. Rabinovich
W. S. Rabinovich
We report a novel spectroscopic technique to characterize photonic waveguides over more than an octave of wavelength. The technique, called mode-crossing spectroscopy, uses a broadband source and a spectrometer that are coupled to the input and output ends of a series of straight dielectric waveguides via single-mode optical fibers. Measurements of the wavelengths at which multiple modes are degenerate in a single waveguide enable the determination of the refractive index of the core, as well as the waveguide width variation. In addition, mode-dependent losses are reported from 700 nm to 1550 nm using waveguides of varying lengths. The core refractive indices are measured within an error of ±0.5%, waveguide width variation to an accuracy of less than 5 nm, and waveguide propagation losses within an error of ±0.5 dB/cm. Ultrabroadband in situ measurements of loss and index over an octave of bandwidth are crucial for the accurate characterization of photonic integrated circuits and devices, especially those based on precision broadband couplers, interferometers, and resonant cavities.

10 March 2020 in ACS Sensors
Verified
Journal Article
Closed access
NTNathan F. Tyndall
Nathan F. Tyndall
TSTodd H. Stievater
Todd H. Stievater
DKDmitry A. Kozak
Dmitry A. Kozak
MPMarcel W. Pruessner
Marcel W. Pruessner
BRBrian J. Roxworthy
Brian J. Roxworthy
Matthew YatesMatthew Yates
Matthew Yates