Relevance. Plastic and reconstructive surgery of the missing outer ear is not always successful and may cause complications. Prosthetic reconstruction using silicone ectoprostheses (epitheses) is an alternative solution to this problem. Purpose – the study aimed to verify clinical and microbiological protocol of prosthetic rehabilitation of patients with a missing auricle using temporary silicone epitheses during implant osseointegration placed for the final magnet-bar retention system and assessment of the prosthetic reconstruction effe ctiveness.Materials and methods. The study compared and analyzed the quality of life and microbial colonization of the skin biotope in the main group patients – with temporary silicone auricle epithesis during extraoral implant osseointegration and in the control group without such prostheses. Quality of life was assessed before and after treatment using the automated questionnaires (WHOQOL-BREF and QL PAER) developed by us for mobile devices. We determined the quantitative and qualitative composition of the skin microbiota behind the ear in all patients with fixed silicone samples for seven days.Results. According to all domains of the "WHOQOL-BREF" and "QL PAER" questionnaires, an integral index of QLI (p < 0.05) was reliably higher after prosthesis fixation in the main group. Skin biotope colonization by strains of resident microorganisms in the region of Technovent silicone epithesis increased if B-460 glue was applied, and the water-soluble G609 glue did not have a similar effect.Conclusion. A digital protocol for the manufacture of a temporary silicone epithesis of the auricle for the period of extraoral implant osseointegration, with the fixation on a water-soluble glue, improves the quality of life of patients with anotia and minimizes microbial colonization of the biotope of t he skin behind the ear.
1 January 2020 in Izvestiya vysshikh uchebnykh zavedenii. Fizika
The measurement and calculation of the mechanical properties of silicone rubber used for the manufacture of a prosthesis for the auricle of patients based on dental CAD/CAM systems, using a hybrid technology that includes traditional and digital methods of manufacturing medical devices were performed. Mechanical tensile tests were carried out in a climatic chamber at various temperatures: -20; 0; 25; 40 °C. All mechanical characteristics of silicone rubber lay in a very limited range of values and monotonically decreased with increasing test temperature from -20 to + 45°C. At the same time, the elastic characteristics (elastic modulus) decreased by 1.55, deformation (fracture deformation) - by 1.98, strength (tensile strength) - by 2.37 times. The average values of tensile strength were 6.54 MPa, fracture deformation - 1480.61%, modulus of elasticity - 0.53 MPa, and temperature gradient: 0.08 MPa/deg, 14.8%/deg and 0.004 MPa/deg, respectively. In the framework of the Mooney - Rivlin hyperelastic model, the coefficients of the model C 01 and C 10 are determined, which can be used as parameters when performing simulation modeling of the stress-strain state of prostheses. Based on the data obtained, an assessment was made of the cross-linked density of the silicone rubber material as a synthetic polymer. It turned out to be equal to 0.49.
The scientific article develops an algorithm for the interaction of manufacturers and consumers of frames reinforcing the bases of complete removable dentures in the large-scale healthcare system of the Russian Federation and dental practice, provides a clinical, technological and economic justification for strengthening such prosthetic structures with mesh frames of various production technologies according to the following criteria: clinical and economic, this refers to a decrease in the number of visits to the dental clinic by patients with complete loss of teeth during prosthetics with complete removable dentures (CRD) with a mesh-frame reinforced base of various production technologies; economic and technological — an increase in the profitability of the sale of CRD with a reinforced base, and a quotient of dividing its service life by a multiplier of the increase in the cost of such a prosthetic structure; socio-economic, estimated by a reduction in public health losses due to breakdowns of prosthetic bases and a reduction in forced downtime associated with patient visits to dentists, when reinforced with frames of various technologies for the production of CRD bases, and thereby the clinic’s profits for unpaid patient work on the reconstruction of CRD damage (warranty case). The results obtained showed that the use of factory-made metal mesh frames for reinforcing the bases of artificial teeth makes it possible to reduce public health losses annually due to breakdowns of prosthetic bases and reduce downtime associated with dental visits by patients by 2.2 billion rubles, factory-made quartz mesh frames reduce public health losses by 1.1 bn rubles per year, and personalized polymer reinforcing perforated frames, individually manufactured using digital 3D printing technology, annually reduce public health losses by 4.4 bn rubles. Printed polymer frames have an advantage over factory-made reinforcing metal mesh frames according to the criteria: clinical and economic — 2 times; economic and technological — 1.5 times; socio-economic — by 2 times, they also have an advantage over quartz mesh frames according to the criteria: clinico-economic — by 3.88 times; economic and technological — by 12.92 times; socio-economic — by 4 times. The multiplicative coefficient of synergy for metal mesh frames is 4.7 bn rubles, for quartz mesh frames it is 0.14 bn rubles, and for polymer printed frames it is 28.1 bn rubles. In other words, the multiplicative coefficient of synergy for a printed polymer frame has an advantage of 6.04 times over a similar indicator for a metal mesh frame, and 200.63 times for a quartz mesh frame, which proves the advantage of printed polymer reinforcing frames.
Fracture of complete removable denture (CRD) bases is common in contemporary prosthodontic practice. High-strength polymer reinforcing meshes, particularly polyether-ether-ketone (PEEK), may serve as an alternative because they can chemically bond to PMMA and increase structural durability. In addition, the base composition can influence microbial adhesion—an important factor for preventing biodeterioration and infectious complications. Objectives — evaluate the effect of integrating a PEEK framework into the denture-base structure on adhesion of marker oral microorganisms, taking into account their specific interactions with composite materials. Materials and methods. Compared monolithic PMMA specimens (heat- and cold-cured), monolithic PEEK, and two PMMA+PEEK composites with a perforated ring-type framework and stoppers of different heights (0.5 mm on both sides; 1.0 mm on one side) (n=5 per group). Test strains: Streptococcus sanguinis, Porphyromonas gingivalis, Staphylococcus aureus, Candida albicans. The adhesion index (Ia) was defined as the fraction of cells retained after standardized inoculation and washing. Significance threshold: α=0.05. Results. On PMMA, bacterial Ia values were 0.54—0.70 (“substantial”), while C. albicans reached 0.74—0.75 (“high”). Relative to PMMA, PEEK showed lower Ia for Str. sanguinis (0.55 vs 0.69—0.70), P. gingivalis (0.34 vs 0.54), and C. albicans (0.59 vs 0.74—0.75) (all p0.05). PMMA+PEEK composites showed lower Ia than PMMA for P. gingivalis (0.47—0.49 vs 0.54; p<0.05) and numerically lower values for Str. sanguinis (0.55—0.58 vs 0.69—0.70) and C. albicans (0.65—0.68 vs 0.74—0.75); for S. aureus differences were not significant (0.65—0.66 vs 0.67—0.69). Conclusions. Embedding a perforated PEEK framework in PMMA reduces adhesion of P. gingivalis and tends to reduce adhesion of Str. sanguinis and C. albicans, without affecting S. aureus. These findings support the bioinert properties of PEEK and its potential to limit microbial contamination of denture bases.
Prosthetic reconstruction of patients with microtia and post-traumatic loss of the auricle of various origins silicone using epithesis is accepted by the professional community of doctors as an alternative method of surgical plastic surgery. Modern epitheses of the auricle are modeled in a CAD system based on a scan of the preserved contralateral natural auricle, the virtual mirror image of which is adapted in a computer modeling program to the prosthetic bed. According to the created virtual model of the auricle, a personalized design of the mold (cuvette) of the auricle ectoprosthesis is modeled, which is made of a heat-resistant polymer using additive printing technology. Objective. To develop a methodology for assessing the quality of life for patients who have undergone the procedure of prosthetic reconstruction of the missing auricle, which is based on the Rasch model of estimating latent variables, which will make it possible to obtain an integral assessment of the quality of life on a linear scale independent of the number of patients and a set of questionnaire questions. Results. The author suggests a direction for obtaining objective assessments based on subjective criteria of patients who have received auricular prosthetics, which is associated with a model for processing private assessments of quality of life when receiving a final assessment. It is based on a new but intensively developing model of objective measurements, which is based on the theory of latent variables.