Andrés Combalia

Andrés Combalia

Auto-generated profile, based on publicly available information

Andrés Combalia

Departament de Cirurgia i Especialitats Medicoquirúrgiques, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona (UB), Barcelona, Spain

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2023 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
ACA. Combalia
A. Combalia
MSMaria V. Sanchez-Vives
Maria V. Sanchez-Vives
TDT. Donegan
T. Donegan
Purpose: This narrative review explores the applications and benefits of immersive virtual reality (VR) in orthopaedics, with a focus on surgical training, patient functional recovery, and pain management. Methods: The review examines existing literature and research studies on immersive VR in orthopaedics, analyzing both experimental and clinical studies. Results: Immersive VR provides a realistic simulation environment for orthopaedic surgery training, enhancing surgical skills, reducing errors, and improving overall performance. In post-surgical recovery and rehabilitation, immersive VR environments can facilitate motor learning and functional recovery through virtual embodiment, motor imagery during action observation, and virtual training. Additionally VR-based functional recovery programs can improve patient adherence and outcomes. Moreover, VR has the potential to revolutionize pain management, offering a non-invasive, drug-free alternative. Virtual reality analgesia acts by a variety of means including engagement and diverting patients’ attention, anxiety reduction, and specific virtual-body transformations. Conclusion: Immersive virtual reality holds significant promise in orthopaedics, demonstrating potential for improved surgical training, patient functional recovery, and pain management but further research is needed to fully exploit the benefits of VR technology in these areas.

14 February 2025 in International Orthopaedics
Verified
Journal Article
Open access
JPJuan Carlos Perdomo-Lizarraga
Juan Carlos Perdomo-Lizarraga
ACAndrés Combalia
Andrés Combalia
JFJenaro Ángel Fernández-Valencia
Jenaro Ángel Fernández-Valencia
JMJuan Carlos Martínez-Pastor
Juan Carlos Martínez-Pastor
LMLaura Morata
Laura Morata
EMErnesto Muñoz-Mahamud
Ernesto Muñoz-Mahamud
Purpose: Debridement, Antibiotic Treatment, and Implant Retention (DAIR) is considered the first-line treatment for early acute Prosthetic Joint Infection (PJI). This study aims to evaluate the five year success rates of early acute PJI managed with DAIR taking into consideration the time from the index surgery. Materials and methods: A retrospective analysis of medical charts for 291 consecutive patients with acute PJI occurring within the first three months after primary or revision arthroplasty was conducted. Patients were stratified into two groups based on DAIR timing: Group (A) patients who underwent DAIR within the first four weeks post-arthroplasty; Group (B) patients who underwent DAIR between five and 12 weeks post- arthroplasty. Success rate was defined as implant in place, without signs of infection and not under suppressive antibiotic treatment. Results: The overall five year success rate for the entire cohort at five years was 62.2%. The mortality rate during the study period was 8.2%. The five year success rate was 64.4% (141 of 219) for Group A and 55.6% (40 of 72) for Group B (p = 0.21). Including deceased patients without signs of infection and retained implants as successful cases, the five year success rates increased to 69.9% for Group A (153 out of 219) and 69.4% for Group B (50 out of 72). The implant survival rate at five years was 73% for Group A and 71% for Group B. Conclusion: Our findings indicate that there are no significant differences between patients who undergo a DAIR procedure within four weeks from those performed between week five and 12. Importantly, the overall success rate decreased from 75.6 to 62.2% in the last three years of follow-up.

24 February 2025 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
ACAndrés Combalia
Andrés Combalia
MCMaite Combalia
Maite Combalia
EMErnesto Muñoz-Mahamud
Ernesto Muñoz-Mahamud
Purpose: Complete acromioclavicular (AC) dislocation associated with fracture of the coracoid process (CP) is uncommon. The strong coracoclavicular ligaments, instead of rupture, may avulse the CP near its base, and with disruption of the AC joint may allow complete dislocation of the clavicle. We report ten cases, one of the largest series in literature, and reviewed the findings and treatment previous reported cases, to allow potential readers to establish the most appropriate treatment. Methods: We have prospectively collected those cases in which we had identified an association of an AC dislocation with a fracture of the CP, as well as retrospectively reviewed the records that were coded as AC dislocations and CP fracture looking for this association in the senior author institutions. A literature search was completed on PubMed, Web of Science and Scholar Google, using a sensitive search strategy. Results: We have collected a total of ten patients with the association of a CP fracture to an AC dislocation in a period of twenty-five years. A review of the cases reported in literature shows a great variability in treatment methods from conservative to more surgically in recent years. Conclusions: When an AC dislocation is identified by clinical examination and X-rays, one should be aware of a possible fracture of the CP. It is possible this association to be more frequent than shown in literature because of the CP fracture can easily be missed out or mistaken with an unfussed epiphysis in routine anteroposterior radiography. Multiple approaches have been opted for by surgeons to deal with this combined injury and are the basis of this review.

1 July 2021 in Injury
Verified
Journal Article
Open access
MCM Combalia
M Combalia
EME Muñoz-Mahamud
E Muñoz-Mahamud
JFJl Febles-Oviedo
Jl Febles-Oviedo
JFJ Fernández-Valencia
J Fernández-Valencia
ACA Combalia
A Combalia

11 August 2022 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
EMErnesto Muñoz-Mahamud
Ernesto Muñoz-Mahamud
CCClara Chimeno
Clara Chimeno
ETEduard Tornero
Eduard Tornero
AAAlfonso Alías
Alfonso Alías
JFJenaro Ángel Fernández-Valencia
Jenaro Ángel Fernández-Valencia
ACAndrés Combalia
Andrés Combalia
Purpose: We hypothesized that the intra-operative measurement of the femoral head may increase the accuracy of the acetabular cup size optimal selection in total hip arthroplasty (THA). The purpose of this clinical research was to analyze the correlation between the estimated cup size from intra-operative measurement of the femoral head and the pre-operative templated cup size. Methods: A prospective observational single-center study was conducted from June 2019 to January 2020 including primary THA (n = 100). All cases were pre-operatively templated. The measurement of the anterior–posterior diameter of the femoral head was routinely intra-operatively performed. Any definitive implanted cup was considered as “oversized” when the size was > 4 mm than the diameter of the native head. Results: The median (interquartile range) size of the implanted cup, pre-operative planned cup size, and diameter of the femoral head were measured 52 (50–54) mm, 50 (48–54) mm and 49 (45–51) mm, respectively. Pre-operative planned size cup accurately predicted the implanted cup or differed in only one size (2 mm) in 77 (78%) cases. Otherwise, intra-operative femoral head measurement method accurately predicted the implanted or differed in only one size (2 mm) in 51 (87%) cases (p = 0.097). Conclusion: The intra-operative femoral head measurement is a simple and reliable tool to help the surgeons choose the best size of the acetabular cup and is as reliable as the pre-operative templating in order to avoid cup oversizing in THA. Utmost caution is warranted whenever the cup reamer is > 4 mm than the anterior–posterior diameter of the native head.

15 May 2023 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
CCClara Chimeno
Clara Chimeno
JFJenaro Ángel Fernández-Valencia
Jenaro Ángel Fernández-Valencia
AAAlfonso Alías
Alfonso Alías
ASAdrià Serra
Adrià Serra
YPYury Postnikov
Yury Postnikov
EMErnesto Muñoz-Mahamud
Ernesto Muñoz-Mahamud
Purpose: Failure to restore the femoral offset of the native hip is a potential cause of dysfunctional hip arthroplasty. The aim of this study was to report our experience of using a modular head–neck adapter in revision THA, specifically analyzing its usefulness as a tool to correct a slightly diminished femoral offset. Materials and methods: This was a retrospective single-center study including all hip revisions performed at our institution from January 2017 to March 2022 where the BioBallTM head–neck metal adapter was used. The preoperative and one year follow-up modified Merle d’Aubigné hip score was used to evaluate functional outcomes. Results: Of a total of 34 cases included for revision, the head–neck adapter system was used specifically in six patients (17.6%) to increase femoral offset, retaining both the acetabular and femoral components. In this subgroup of patients, mean offset decrease after primary THA was 6.6 mm (4.0–9.1), equivalent to a mean 16.3% femoral offset reduction. The median modified Merle d’Aubigné score went from 13.3 preoperatively to 16.2 at one year follow-up. Conclusion: The use of a head–neck adapter is a safe and reliable procedure that may allow the surgeon to easily correct a slightly diminished femoral offset in a dysfunctional THA without the need to revise well-fixed prosthetic components.