1 May 2011 in RadioGraphics
Mobile image intensifier systems (C-arms) are used frequently in orthopedic and reconstructive surgery, especially in trauma and emergency settings, but image quality and radiation exposure levels may vary widely, depending on the extent of the C-arm operator's knowledge and experience. Current training programs consist mainly of theoretical instruction in C-arm operation, the physical foundations of radiography, and radiation avoidance, and are largely lacking in hands-on application. A computer-based simulation program such as that tested by the authors may be one way to improve the effectiveness of C-arm training. In computer simulations of various scenarios commonly encountered in the operating room, trainees using the virtX program interact with three-dimensional models to test their knowledge base and improve their skill levels. Radiographs showing the simulated patient anatomy and surgical implants are "reconstructed" from data computed on the basis of the trainee's positioning of models of a C-arm, patient, and table, and are displayed in real time on the desktop monitor. Trainee performance is signaled in real time by color graphics in several control panels and, on completion of the exercise, is compared in detail with the performance of an expert operator. Testing of this computer-based training program in continuing medical education courses for operating room personnel showed an improvement in the overall understanding of underlying principles of intraoperative radiography performed with a C-arm, with resultant higher image quality, lower overall radiation exposure, and greater time efficiency. Supplemental material available at http://radiographics.rsna.org/lookup/suppl/doi:10.1148/rg.313105125/-/DC1.
1 January 2008 in Methods of Information in Medicine
Summary Objectives: Operating room personnel (ORP) operating mobile image intensifier systems (C-arms) need training to produce high quality radiographs with a minimum of time and X-ray exposure. Our study aims at evaluating acceptance, usability and learning effect of the CBT system virtX that simulates C-arm based X-ray imaging in the context of surgical case scenarios. Methods: Prospective, interventional study conducted during an ORP course with three groups: intervention group 1 (training on a PC using virtX), and 2 (virtX with a C-arm as input device), and a control group (training without virtX) – IV1, IV2 and CG. All participants finished training with the same exercise. Time needed to produce an image of sufficient quality was recorded and analyzed using One-Way-ANOVA and Dunnett post hoc test (? = .05). Acceptance and usability of virtX have been evaluated using a questionnaire. Results: CG members (n = 21) needed more time for the exercise than those of IV2 (n = 20): 133 ± 55 vs. 101 ± 37 sec. (p = .03). IV1 (n = 12) also performed better than CG (128 ± 48 sec.), but this was not statistically significant. Seventy-nine participants returned a questionnaire (81% female, age 34 ± 9 years, professional experience 8.3 ± 7.6 years; 77% regularly used a C-arm). 83% considered virtX a useful addition to conventional C-arm training. 91% assessed virtual radiography as helpful for understanding C-arm operation. Conclusions: Trainees experienced virtX as substantial enhancement of C-arm training. Training with virtX can reduce the time needed to perform an imaging task.
27 March 2007 in Journal of Digital Imaging