Jennifer Ashton

Jennifer Ashton

Auto-generated profile, based on publicly available information

Jennifer Ashton

Department of Psychology, University of York, York, YO10 5DD, UK

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
OSOrsolya Székely
Orsolya Székely
NHNicholas Paul Holmes
Nicholas Paul Holmes
JAJennifer Ashton
Jennifer Ashton
FBFriederike Breuer
Friederike Breuer
HCHsin-Yuan Chen
Hsin-Yuan Chen
LTLuigi Tame
Luigi Tame
Highlights: We introduce the TMS-RAT, a reporting (assessment) tool for TMS studies Developed within a community-informed, iterative process rating 333 TMS studies Empirically evaluated for usability, inter-rater, and test-retest reliability A validated subset enables reliable retrospective assessment of reporting The modular structure enables use across a wide range of TMS study designs Background: A standardised tool for comprehensive reporting can improve transparency, support consistent documentation, and enable comparison across transcranial magnetic stimulation (TMS) studies. The most used reporting checklist lacks clear definitions of full reporting and was not initially evaluated for usability or inter-rater reliability. A scoping review of studies using this checklist shows that its items are reported only 50% of the time, suggesting that method descriptions are often incomplete. Methods: We developed the TMS Reporting Assessment Tool (TMS-RAT), a comprehensive reporting framework that provides clear definitions and examples for its items, covering a wide range of TMS protocols. We tested the usability and reliability of the TMS-RAT by rating all studies published between 1991 and 2025 using afferent conditioning (n = 333), a protocol encompassing many reporting categories identified during tool development. Seventeen independent raters contributed across three development phases, a validation phase, and a retest phase, with naïve raters introduced in each phase. Iterative refinements of the tool were informed by inter-rater reliability, qualitative rater feedback, and consultation with external TMS experts. Results: We present two versions of the tool: the 72-item TMS-RAT v1.0, designed to guide comprehensive reporting, and the TMS-RAT v1.1, a subset of 50 items with the highest inter-rater (overall AC1 = 0.78, range = [0.60–0.99]) and test-retest reliability (overall AC1 = 0.82, range = [0.65–1.0]), intended for retrospective evaluation of reporting in systematic reviews, meta-analyses. Conclusion: The TMS-RAT is a comprehensive, reliable tool that seeks to improve transparency and reproducibility in TMS research.

11 July 2026 in Brain Stimulation
Verified
Journal Article
Open access
OSOrsolya Székely
Orsolya Székely
NHNicholas P. Holmes
Nicholas P. Holmes
JAJennifer Ashton
Jennifer Ashton
FBFriederike Breuer
Friederike Breuer
HCHsin-Yuan Chen
Hsin-Yuan Chen
LTLuigi Tame
Luigi Tame
A standardised tool for comprehensive reporting can improve transparency, support consistent documentation, and enable comparison across transcranial magnetic stimulation (TMS) studies. To date, the most used reporting checklist lacks definitions of full reporting and was not initially evaluated for usability or reliability. We developed the TMS Reporting Assessment Tool (TMS-RAT), a comprehensive reporting framework that provides clear definitions and examples for its items. We tested the usability and reliability of the TMS-RAT by rating all studies published between 1987 and 31st January 2025 using afferent conditioning (n = 333), protocols that encompass many reporting categories identified during tool development. Seventeen independent raters contributed across three development phases, a validation phase, and a retest phase, with naïve raters introduced in each phase. Iterative refinements of the tool were informed by inter-rater reliability, qualitative rater feedback, and consultation with external TMS experts. We present two versions of the tool: the 72-item TMS-RAT v1.0, designed to guide comprehensive reporting, and the TMS-RAT v1.1, a subset of 50 items with the highest inter-rater (overall AC1 = 0.78, range = [0.60-0.99]) and test-retest reliability (overall AC1 = 0.82, range = [0.65-1.0]), intended for retrospective evaluation of reporting in systematic reviews and meta-analyses. The tool has not been validated outside the afferent conditioning literature or on studies not recording motor evoked potentials. The TMS-RAT is a comprehensive, reliable tool that seeks to improve transparency and reproducibility in TMS research. We aim to extend the tool to cover additional TMS protocols.