Koffi Mawugno Kodjo

Koffi Mawugno Kodjo

Auto-generated profile, based on publicly available information

Koffi Mawugno Kodjo

Centre d'Excellence Régional pour la Maîtrise de l'Electricité (CERME), Université de Lomé, 01 BP 1515 Lomé 01, Togo

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2013 in Renewable Energy
Verified
Journal Article
Closed access
ASADEKUNLE AKIM SALAMI
ADEKUNLE AKIM SALAMI
AAAyite Senah Akoda Ajavon
Ayite Senah Akoda Ajavon
MKMawugno Koffi Kodjo
Mawugno Koffi Kodjo
KBKoffi-Sa Bedja
Koffi-Sa Bedja

4 November 2016 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
ASADEKUNLE AKIM SALAMI
ADEKUNLE AKIM SALAMI
AAAyité Sénah Akoda Ajavon
Ayité Sénah Akoda Ajavon
MKMawugno Koffi Kodjo
Mawugno Koffi Kodjo
KBKoffi-Sa Bedja
Koffi-Sa Bedja
This work presents the characterization and assessment of wind energy potential in annual and monthly levels of the sites of Lomé, Accra and Cotonou located in the Gulf of Guinea, and the optimal characteristics of wind turbines to be installed on these sites. Studies of characterization and the wind potential of these sites from the wind speed data collected over a period of thirteen years at a height of 10 meters above the ground, show an annual average speed of 3.52 m/s for Lomé, 3.99 m/s for Cotonou and 4.16 m/s for Accra. These studies also showed that a monthly average speed exceeding 4 m/s was observed on the sites of Cotonou and Accra during the months of February, March, April, July, August and September and during the months of July, August and September on the site of Lomé. After a series of simulation conducted using the software named PotEol that we have developed in Scilab, we have retained that the wind turbines rated speeds of ~8 to 9 m/s at the sites of Lomé and Cotonou and ~ 9 to 10 m/s on the site of Accra would be the most appropriate speeds for optimal exploitation of electric energy from wind farms at a height of 50 m above the ground.Article History: Received May 26th 2016; Received in revised form August 24th 2016; Accepted August 30th 2016; Available onlineHow to Cite This Article: Salami, A.A., Ajavon, A.S.A , Kodjo, M.K. and Bédja, K. (2016) Evaluation of Wind Potential for an Optimum Choice of Wind Turbine Generator on the Sites of Lomé, Accra, and Cotonou Located in the Gulf of Guinea. Int. Journal of Renewable Energy Development, 5(3), 211-223.http://dx.doi.org/10.14710/ijred.5.3.211-223

24 February 2023 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
ETEsso-Wazam Honoré Tchandao
Esso-Wazam Honoré Tchandao
ASADEKUNLE AKIM SALAMI
ADEKUNLE AKIM SALAMI
KKKoffi Mawugno Kodjo
Koffi Mawugno Kodjo
ANAmy Nabiliou
Amy Nabiliou
SOSeydou Ouedraogo
Seydou Ouedraogo
This work uses bottom-up modeling to explore the future evolution trajectories of the electricity mix in Togo by 2050. The objective is to investigate the evolution of the mix and the future investments needed to achieve the sustainable energy and climate change goals. Three scenarios were developed using OSeMOSYS. The reference scenario, named Business As Usual, closely reflects the evolution of the Togolese electricity sector under a business-as-usual assumption and planned capacity increases up to 2030. The second scenario, Net Zero by 2050, is based on the first scenario while ensuring that CO2 emissions cancel out in 2050 by following the Weibull law. The third scenario called Emission Penalty aims not only at the integration of renewable energies like the second one but also at the least cost electricity mix if emission penalties are applied. The results of the cost optimization indicate that photovoltaic and importation are the optimal choices ahead of gas and hydropower. The renewable energy aspect of the electricity mix is more highlighted in the last scenario. At the same time, the model shows that greater energy independence is achievable at the cost of a transitory increase in the cost of the electricity system. A tenfold investment effort is needed in 2030 to ensure either continuity of the status quo or a shift in strategy.

10 July 2018 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
ASADEKUNLE AKIM SALAMI
ADEKUNLE AKIM SALAMI
AAAyité Sénah Akoda Ajavon
Ayité Sénah Akoda Ajavon
MKMawugno Koffi Kodjo
Mawugno Koffi Kodjo
SOSeydou Ouedraogo
Seydou Ouedraogo
KBKoffi-Sa Bédja
Koffi-Sa Bédja
In this article, we introduced a new approach based on graphical method (GPM), maximum likelihood method (MLM), energy pattern factor method (EPFM), empirical method of Justus (EMJ), empirical method of Lysen (EML) and moment method (MOM) using the even or odd classes of wind speed series distribution histogram with 1 m/s as bin size to estimate the Weibull parameters. This new approach is compared on the basis of the resulting mean wind speed and its standard deviation using seven reliable statistical indicators (RPE, RMSE, MAPE, MABE, R2, RRMSE and IA). The results indicate that this new approach is adequate to estimate Weibull parameters and can outperform GPM, MLM, EPF, EMJ, EML and MOM which uses all wind speed time series data collected for one period. The study has also found a linear relationship between the Weibull parameters K and C estimated by MLM, EPFM, EMJ, EML and MOM using odd or even class wind speed time series and those obtained by applying these methods to all class (both even and odd bins) wind speed time series. Another interesting feature of this approach is the data size reduction which eventually leads to a reduced processing time.Article History: Received February 16th 2018; Received in revised form May 5th 2018; Accepted May 27th 2018; Available onlineHow to Cite This Article: Salami, A.A., Ajavon, A.S.A., Kodjo, M.K. , Ouedraogo, S. and Bédja, K. (2018) The Use of Odd and Even Class Wind Speed Time Series of Distribution Histogram to Estimate Weibull Parameters. Int. Journal of Renewable Energy Development 7(2), 139-150.https://doi.org/10.14710/ijred.7.2.139-150

1 October 2019
Verified
Conference Paper
Closed access
KDKoffi Agbeblewu Dotche
Koffi Agbeblewu Dotche
ASADEKUNLE AKIM SALAMI
ADEKUNLE AKIM SALAMI
KKKoffi Mawugno Kodjo
Koffi Mawugno Kodjo
YBYawa Pamela C. D. Blu
Yawa Pamela C. D. Blu
YDYao Essemu Julien Diabo
Yao Essemu Julien Diabo
The work sought to develop a model for the evaluation of solar energy harvesting potentials in Togo using an approach based on artificial neural networks (ANNs) in order to predict the daily irradiation for some areas under climatic conditions. Two types of ANN architecture were evaluated the radial basic function (RBF) and multi-layer perceptron (MLP). The data were collected in 28 cities, and data from of 8 cities were used for the training stage in order to come with the suitable model for the other cities. The results indicated that the ANN-MLP model 8 has provided the best performance and its accuracy was tested. Furthermore, the solar generation potential was evaluated. The sites in the study have exhibited a high potential for solar energy generation.

1 August 2019
Verified
Conference Paper
Closed access
YBYao Bokovi
Yao Bokovi
ASADEKUNLE AKIM SALAMI
ADEKUNLE AKIM SALAMI
KKKoffi Mawugno Kodjo
Koffi Mawugno Kodjo
KDKoffi Agbeblewu Dotche
Koffi Agbeblewu Dotche
KBKoffi-Sa Bedja
Koffi-Sa Bedja
This paper has evaluated a comparative study of the voltage drops on electrical distribution grid by a simulation platform. The computation of the voltage drop computation was done by the use of two methods. Firstly, with the help of a simplified power line model a theoretical calculation has been performed. The considered distribution networks, which can be splitted broadly into two the high and low tension: the high-tension has two classes A and B (High Tension class A denoted as HTA); and low voltage (LV), which has also two classes A and B. The second method has consisted in modelling the HTA distribution’s power grid in Matrix Laboratory (MatLab) software using the Power System Analysis Toolbox (PSAT) as a simulation platform. Both methods were compared against the data of the voltage drops that were obtained from the electricity utility. The results have shown that the implemented PSAT’s model has given a reliable and fast consistent computation as compared to the conventional classical calculation method. The proposed designed model in the PSAT’s application could be useful in the decisions such as the voltage drop correction, maintenance, planning, and for the reliability of the HTA power grid.