10 February 2021 in Nature
4 May 2018 in Physical Review D
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6 and 5.8 GHz. We exclude axion models with two photon coupling , a factor of 2.7 above the benchmark KSVZ model over the mass range . This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment’s system noise temperature to only twice the standard quantum limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA.
9 February 2017 in Physical Review Letters
We report on the first results from a new microwave cavity search for dark matter axions with masses above . We exclude axion models with two-photon coupling over the range . These results represent two important achievements. First, we have reached cosmologically relevant sensitivity an order of magnitude higher in mass than any existing limits. Second, by incorporating a dilution refrigerator and Josephson parametric amplifier, we have demonstrated total noise approaching the standard quantum limit for the first time in an axion search.
3 May 2019 in Physical Review X
Many experiments that interrogate fundamental theories require detectors whose sensitivities are limited by the laws of quantum mechanics. In cavity-based searches for axionic dark matter, vacuum fluctuations in the two quadratures of the cavity electromagnetic field limit the sensitivity to an axion-induced field. In an apparatus designed to partially mimic existing axion detectors, we demonstrate experimentally that such quantum limits can be overcome through the use of squeezed states. By preparing a microwave cavity in a squeezed state and measuring just the squeezed quadrature, we enhance the spectral scan rate by a factor of . This enhancement is in excellent quantitative agreement with a theoretical model accounting for both imperfect squeezing and measurement.
1 May 2017 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
30 April 2021 in Physical Review Letters
We use our recent electric dipole moment (EDM) measurement data to constrain the possibility that the EDM oscillates in time due to interactions with candidate dark matter axionlike particles (ALPs). We employ a Bayesian analysis method which accounts for both the look-elsewhere effect and the uncertainties associated with stochastic density fluctuations in the ALP field. We find no evidence of an oscillating EDM over a range spanning from 27 nHz to 400 mHz, and we use this result to constrain the ALP-gluon coupling over the mass range . This is the first laboratory constraint on the ALP-gluon coupling in the range, and the first laboratory constraint to properly account for the stochastic nature of the ALP field.