24 December 2020 in IEEE Transactions on Instrumentation and Measurement
A distributed phase measurement method of frequency-domain electromagnetic detection is proposed. The theoretical analysis of the previous literature shows that in electromagnetic detection applications, phase as an independent measurement parameter can reduce the diversity of solution, and it also has the advantage of greater steepness than the amplitude. Currently, there are few literature dealing with the phase in the practical application of audio electromagnetic detection, because it is difficult to obtain the phase from the separated devices. A synchronization recording system is designed based on the most widely used GPS and fiducial timestamp (FIDTS) technology. The phase errors caused by FIDTS, hardware circuit noise, and FFT spectrum leakage are analyzed. In addition, the synchronization data lost by GPS can be supplemented by interpolation. To prove the effectiveness of the method, a test platform was built in the laboratory. System test results show that the synchronization error between any two systems is less than 48 ns, and the phase error is less than 0.173° at 10 kHz. The experimental result of abnormal loop shows that the phase is more accurate than the amplitude.
20 April 2022 in IEEE Sensors Journal
Air-core coil sensors are widely used in geophysical electromagnetic exploration because of their ease of production, high sensitivity, and broadband. In order to increase the bandwidth of the air-core coil without reducing the number of turns, a new type of dual-air-core coil sensor was proposed for the shallow exploration in the electromagnetic method. The design principle of the dual-air-core coil sensor was introduced, consisting of a low-bandwidth coil and a high-bandwidth coil. The output voltage of the high-frequency coil is used as a linear reference to obtain the amplitude-frequency response data of the low-frequency coil, and the fitting model is constructed to extract the equivalent inductance and distributed capacitance of the low-frequency coil, so as to realize the correction of the system response. In addition, the crosstalk model between air-core coils was established, and a method to suppress crosstalk was proposed. In order to prove the feasibility of the dual-air-core coil sensor, in-laboratory and field test platforms were set up. The experimental results show that the crosstalk between the coils can be eliminated by adjusting the relative position of the coil. The fitting method can effectively increase the bandwidth of the low-bandwidth coil, so that it exceeds the high-frequency coil used, and it is shown to have better performance. The effective area is 59.5 m2, the amplitude bandwidth of -3 dB is 200 kHz, the phase bandwidth with the error less than ±5° is 220 kHz, and the noise level is 18 fT∙Hz-1/2 at 1 kHz.
13 February 2025 in IEEE Transactions on Instrumentation and Measurement
The high-linearity and low noise amplifier has been developed as a core module to improve the testing accuracy and weak signal capture ability of the high-precision digital multimeter. This article focuses on optimizing the linearity and noise of the dc amplifier by using the nonlinearity of the current mirror to compensate for junction field-effect transistor (JFET) mismatch. This effectively suppresses the second-order nonlinearity caused by JFET mismatch and results in a high-linearity parameter model. The device noise of the dc amplifier is carefully selected and optimized under this high-linearity model. The experiment shows that under linear fitting, the nonlinear errors of the dc amplifier are 15, 9, and 4 ppm for input voltages of 0.1, 1, and 10 V, respectively. This is a significant improvement compared to the nonlinear errors before optimizing the current mirror structure, which were reduced by 100 times. The linear fitting error of the dc amplifier is now less than that of the Keysight 37740A. The white noise of the dc amplifier is also improved, with a value of less than 6 nV/Hz ${}^{1/2}$ , and the peak-to-peak noise is now 282 nV, which is equivalent to the noise performance of the Keysight 37740A. Under third-order polynomial fitting, the nonlinear errors of the dc amplifier are 5, 4.8, and 0.5 ppm for input voltages of 0.1, 1, and 10 V, respectively. This is comparable to the linearity performance of the Fluke 8508A. The peak-to-peak noise of the amplifier after average processing is also equivalent to the noise performance of the Fluke 8508A.