Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computed tomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landmarks from two different observers and automatically assessed landmarks. Both of the automatic approaches were within the interobserver accuracy for normal specimens, and the non-rigid approach was within the interobserver accuracy for the Crouzon specimens. Four linear measurements, skull length, height and width and interorbital distance, were carried out automatically using the two different approaches. Both automatic approaches assessed the skull length, width and height accurately for both groups of mice. The non-rigid approach measured the interorbital distance accurately for both groups while the affine approach failed to assess this parameter for both groups. Using the full capability of the non-rigid approach, local displacements obtained when registering the non-rigid wild-type atlas to a non-rigid Crouzon mouse atlas were determined on the surface of the wild-type atlas. This revealed a 0.6-mm bending in the nasal region and a 0.8-mm shortening of the zygoma, which are similar to characteristics previously reported in humans. The most striking finding of this analysis was an angulation of approximately 0.6 mm of the cranial base, which has not been reported in humans. Comparing the two different methodologies, it is concluded that the non-rigid approach is the best way to assess linear skull parameters automatically. Furthermore, the non-rigid approach is essential when it comes to analysing local, non-linear shape differences.
This paper combines different parallelization strategies for speeding up motion and deformation computation by non-rigid registration of a sequence of images. The registration is performed in a two-level acceleration approach: (1) parallelization of each registration process using MPI and/or threads, and (2) distribution of the sequential registrations over a cluster. On a 24-node double quad-core Intel Xeon (2.66 GHz CPU, 16 GB RAM) cluster, the method is demonstrated to efficiently compute the deformation of a cardiac sequence reducing the computation time from more than 3 hours to a couple of minutes (for low downsampled images). It is shown that the distribution of the sequential registrations over the cluster together with the parallelization of each pairwise registration by multithreading lowers the computation time towards values compatible with clinical requirements (a few minutes per patient). The combination of MPI and multithreading is only advantageous for large input data sizes. Performances are assessed for the specific scenario of aligning cardiac sequences of taggedMagnetic Resonance (tMR) images, with the aim of comparing strain in healthy subjects and hypertrophic cardiomyopathy (HCM) patients. In particular, we compared the distribution of systolic strain in both populations. On average, HCM patients showed lower average values of strain with larger deviation due to the coexistence of regions with impaired deformation and regions with normal deformation.
E13538 Background: The use of lesion volume is considered as a promising alternative to RECIST (Response Evaluation Criteria in Solid Tumors) to make tumor measurements more accurate, consistent, and for earlier detection of changes. Herein, we report the results of a pilot study aiming at evaluating the effects of target (TL) and new lesions (NL) selection on volume-based response (VBR) assessments, thanks to cloud solutions intended to standardize evaluations in multi-center clinical trials. Methods: 11 lung cancer patients with CT scans acquired at 3 time points were retrospectively selected from RIDER (Reference Image Database to Evaluate Therapy Response) and proprietary databases. Images were analyzed according to RECIST and VBR criteria by two oncologists (Japan and Scotland) and one radiologist (France) by using cloud solutions (MEDIAN Technologies). They allowed carrying out a consensus process on the choice of the TL and NL used for computing response. As there are no accepted thresholds for ass...