Laura Carot

Laura Carot

Auto-generated profile, based on publicly available information

Laura Carot

Gastroenterology Department, Hospital del Mar, Barcelona, Spain

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2016 in Endoscopy
Verified
Journal Article
Open access
PDF file
MÁMarco Antonio Álvarez-González
Marco Antonio Álvarez-González
JRJuana A. Flores-Le Roux
Juana A. Flores-Le Roux
ASAgustin Seoane
Agustin Seoane
JPJuan Pedro-Botet
Juan Pedro-Botet
LCLaura Carot
Laura Carot
VLVicente Lorenzo-Zuniga
Vicente Lorenzo-Zuniga
Background and study aims: Previous studies have reported that diabetes mellitus is an independent risk factor for inadequate bowel preparation. Current guidelines do not recommend a specific preparation for this patient population. The aims of this study were to assess the efficacy, safety, and tolerability of an adapted preparation protocol for colon cleansing in patients with type 2 diabetes mellitus. Patients and methods: This randomized, single-blind, parallel group, superiority trial compared a conventional bowel preparation protocol (CBP) with a diabetes-specific preparation protocol (DSP). The CBP included a low-fiber diet for 3 days followed by a clear liquid diet for 24 hours before colonoscopy. The DSP included a multifactorial strategy combining an educational intervention, a low-fiber diet, and adjustment of blood glucose-lowering agents. All patients received 4 L of a polyethylene glycol solution in a split-dose regimen. The endoscopists were blinded to the preparation protocol. The primary outcome measure was inadequate bowel preparation according to the Boston Bowel Preparation Scale. Secondary outcome measures included hypoglycemic events, tolerability, and acceptability. Results: A total of 150 patients were included in the study (74 CBP and 76 DSP). Both groups were comparable in terms of baseline characteristics. Inadequate bowel cleansing was more frequent following CBP than DSP (20 % vs. 7 %, P = 0.014; risk ratio 3.1, 95 % confidence interval 1.2 – 8). Only CBP and performance status were independently associated with inadequate bowel preparation. Both preparations were equally tolerated and accepted by patients, and side-effects were similar between the groups. Conclusions: A multifactorial strategy for bowel preparation in patients with diabetes undergoing colonoscopy showed a threefold reduction in the rate of inadequate bowel preparation, with no differences in safety and tolerability compared with conventional preparation. Trial registration: ClinicalTrials.gov (NCT02300779).

1 December 2018 in United European Gastroenterology Journal
Verified
Journal Article
Open access
LCLaura Carot
Laura Carot
ACAntoni Castells
Antoni Castells
CHCristina Hernández
Cristina Hernández
CACristina Alvarez-Urturi
Cristina Alvarez-Urturi
FBFrancesc Balaguer
Francesc Balaguer
CSColonPrev study
ColonPrev study
Background: The diagnostic yield of the faecal immunochemical test and sigmoidoscopy in detecting proximal serrated polyps in a colorectal cancer screening programme has not been fully assessed.Aim: We determined the detection rate of proximal serrated polyps by simulated sigmoidoscopy and faecal immunochemical test compared with total colonoscopy in a population‐based, multicentre, nationwide, randomised controlled trial (ColonPrev study).Methods: Sigmoidoscopy yield was simulated based on the UK‐Flexible Sigmoidoscopy Trial for total colonoscopy referral. Definitions were: proximal serrated polyp (proximal serrated polyp): sessile serrated polyp or hyperplastic polyp of any size and proximal at‐risk serrated polyp (at‐risk proximal serrated polyp): sessile serrated polyp of any size or hyperplastic polyp ≥ 10 mm, both located proximally to the splenic flexure.Results: A total of 10,611 individuals underwent faecal immunochemical test and 5059 underwent total colonoscopy and were evaluated by simulated sigmoidoscopy. Sigmoidoscopy and faecal immunochemical test were less accurate in detecting proximal serrated polyps (odds ratio: 0.13; 95% confidence interval: 0.10–0.18 and 0.13; 0.09–0.18, p < 0.0001, respectively). Both tests were inferior to colonoscopy in detecting at‐risk proximal serrated polyps, and sigmoidoscopy was inferior to faecal immunochemical test in detecting these lesions (odds ratio: 0.17; 95% confidence interval: 0.10–0.30 and 0.25; 0.17–0.37, p < 0.0001, respectively).Conclusion: Sigmoidoscopy and faecal immunochemical test are less accurate in detecting proximal serrated polyps than colonoscopy, particularly in women.

1 January 2018 in FMC - Formación Médica Continuada en Atención Primaria
Verified
Journal Article
Closed access
LCLaura Carot
Laura Carot
AFAgnès Fernández
Agnès Fernández
DZDiana Zaffalon
Diana Zaffalon
JDJosep Maria Dedeu
Josep Maria Dedeu
XBXavier Bessa
Xavier Bessa

1 April 2016 in Gastroenterology
Verified
Journal Article
Closed access
PDF file
LCLaura Carot
Laura Carot
CHCristina Hernández
Cristina Hernández
CÁCristina Álvarez-Urturi
Cristina Álvarez-Urturi
JAJosep M Augé
Josep M Augé
ABAndrea Burón
Andrea Burón
XBXavier Bessa
Xavier Bessa

1 April 2016 in Gastroenterology
Verified
Journal Article
Closed access
PDF file
LCLaura Carot
Laura Carot
ARAgnés Raga
Agnés Raga
CHCristina Hernández
Cristina Hernández
ABAndrea Burón
Andrea Burón
MCMerce Comas
Merce Comas
XBXavier Bessa
Xavier Bessa