Ethan A. Rossi

Ethan A. Rossi

Auto-generated profile, based on publicly available information

Ethan A. Rossi

Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2009 in Nature Neuroscience
Verified
Journal Article
Open access
PDF file
EREthan A Rossi
Ethan A Rossi
ARAustin Roorda
Austin Roorda
Visual resolution is best at the center of the retina, where the cones are packed together most closely, and decreases outside of this area, where cones are farther apart. Combining adaptive optics imaging and psychophysical testing, the authors reveal that resolution actually falls off much more quickly than cone spacing would predict. Visual resolution decreases rapidly outside of the foveal center. The anatomical and physiological basis for this reduction is unclear. We used simultaneous adaptive optics imaging and psychophysical testing to measure cone spacing and resolution across the fovea, and found that resolution was limited by cone spacing only at the foveal center. Immediately outside of the center, resolution was worse than cone spacing predicted and better matched the sampling limit of midget retinal ganglion cells.

3 January 2017 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
EREthan A. Rossi
Ethan A. Rossi
CGCharles E. Granger
Charles E. Granger
RSRobin Sharma
Robin Sharma
QYQiang Yang
Qiang Yang
KSKenichi Saito
Kenichi Saito
DWDavid R. Williams
David R. Williams
Significance: Retinal ganglion cells are the primary output neurons of the retina that process visual information and transmit it to the brain. We developed a method to reveal these cells in the living eye that does not require the fluorescent labels or high light levels that characterize more invasive methods. The death of these cells causes vision loss in glaucoma, the second leading cause of blindness worldwide. The ability to image these cells in the living eye could accelerate our understanding of their role in normal vision and provide a diagnostic tool for evaluating new therapies for retinal disease.

1 May 2007 in Journal of Vision
Verified
Journal Article
Open access
PDF file
EREthan A. Rossi
Ethan A. Rossi
PWPinky Weiser
Pinky Weiser
JTJanice Tarrant
Janice Tarrant
ARAustin Roorda
Austin Roorda
Myopic observers may not benefit to the same extent as emmetropes from adaptive optics (AO) correction in a visual acuity (VA) task. To investigate this, we measured AO-corrected VA in 10 low myopes and 9 emmetropes. Subjects were grouped by refractive error. Mean spherical equivalent refractive error was −2.73 D ( SEM = 0.35) for the myopes and 0.04 D ( SEM = 0.1) for the emmetropes. All subjects had best corrected VA of 20/20 or better. The AO scanning laser ophthalmoscope was used to project ultrasharp stimuli onto the retina of each observer. High-contrast photopic acuity was measured using a tumbling E test with and without AO correction. AO-corrected minimum angle of resolution was 0.61′ ( SEM = 0.02′) for the myopes and 0.49′ ( SEM = 0.03′) for the emmetropes. The difference between groups is significant ( p = .0017). This effect is even greater ( p = .00013) when accounting for spectacle magnification and axial length, with myopes and emmetropes able to resolve critical features on the retina with a mean size of 2.87 μm ( SEM = 0.07) and 2.25 μm ( SEM = 0.1), respectively. Emmetropes and low myopes will both benefit from AO correction in a VA task but not to the same extent. Optical aberrations do not limit VA in low myopia after AO correction. There is no difference in the high-order aberrations of emmetropes and low myopes. Retinal and/or cortical factors limit VA in low myopes after AO correction.

10 March 2011 in Eye
Verified
Journal Article
Closed access
ERE A Rossi
E A Rossi
MCM Chung
M Chung
ADAlfredo Dubra
Alfredo Dubra
JHJ J Hunter
J J Hunter
WMW H Merigan
W H Merigan
DWD R Williams
D R Williams

26 August 2014 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
QYQiang Yang
Qiang Yang
JZJie Zhang
Jie Zhang
KNKoji Nozato
Koji Nozato
KSKenichi Saito
Kenichi Saito
DWDavid R. Williams
David R. Williams
EREthan A. Rossi
Ethan A. Rossi
Eye motion is a major impediment to the efficient acquisition of high resolution retinal images with the adaptive optics (AO) scanning light ophthalmoscope (AOSLO). Here we demonstrate a solution to this problem by implementing both optical stabilization and digital image registration in an AOSLO. We replaced the slow scanning mirror with a two-axis tip/tilt mirror for the dual functions of slow scanning and optical stabilization. Closed-loop optical stabilization reduced the amplitude of eye-movement related-image motion by a factor of 10–15. The residual RMS error after optical stabilization alone was on the order of the size of foveal cones: ~1.66–2.56 μm or ~0.34–0.53 arcmin with typical fixational eye motion for normal observers. The full implementation, with real-time digital image registration, corrected the residual eye motion after optical stabilization with an accuracy of ~0.20–0.25 μm or ~0.04–0.05 arcmin RMS, which to our knowledge is more accurate than any method previously reported.

18 October 2013 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
EREthan A. Rossi
Ethan A. Rossi
PRPiero Rangel-Fonseca
Piero Rangel-Fonseca
KPKeith Parkins
Keith Parkins
WFWilliam Fischer
William Fischer
LLLisa R. Latchney
Lisa R. Latchney
MCMina M. Chung
Mina M. Chung
Morgan and colleagues demonstrated that the RPE cell mosaic can be resolved in the living human eye non-invasively by imaging the short-wavelength autofluorescence using an adaptive optics (AO) ophthalmoscope. This method, based on the assumption that all subjects have the same longitudinal chromatic aberration (LCA) correction, has proved difficult to use in diseased eyes, and in particular those affected by age-related macular degeneration (AMD). In this work, we improve Morgan’s method by accounting for chromatic aberration variations by optimizing the confocal aperture axial and transverse placement through an automated iterative maximization of image intensity. The increase in image intensity after algorithmic aperture placement varied depending upon patient and aperture position prior to optimization but increases as large as a factor of 10 were observed. When using a confocal aperture of 3.4 Airy disks in diameter, images were obtained using retinal radiant exposures of less than 2.44 J/cm2, which is ~22 times below the current ANSI maximum permissible exposure. RPE cell morphologies that were strikingly similar to those seen in postmortem histological studies were observed in AMD eyes, even in areas where the pattern of fluorescence appeared normal in commercial fundus autofluorescence (FAF) images. This new method can be used to study RPE morphology in AMD and other diseases, providing a powerful tool for understanding disease pathogenesis and progression, and offering a new means to assess the efficacy of treatments designed to restore RPE health.