Hao Ho

Hao Ho

Auto-generated profile, based on publicly available information

Hao Ho

Institute of Statistical Science, Academia Sinica

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2021 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
YCYinyin Chen
Yinyin Chen
DRDaoyuan Ren
Daoyuan Ren
XGXingmin Guan
Xingmin Guan
HYHsin-Jung Yang
Hsin-Jung Yang
TLTing Liu
Ting Liu
RDRohan Dharmakumar
Rohan Dharmakumar
T2* cardiovascular magnetic resonance (CMR) is commonly used in the diagnosis of intramyocardial hemorrhage (IMH). For quantifying IMH with T2* CMR, despite the lack of consensus studies, two different methods [subject-specific T2* (ssT2*) and absolute T2* thresholding (aT2* < 20 ms)] are interchangeably used. We examined whether these approaches yield equivalent information. ST elevation myocardial infarction (STEMI) patients (n = 70) were prospectively recruited for CMR at 4–7 days post revascularization and for 6-month follow up (n = 43). Canines studies were performed for validation purposes, where animals (n = 20) were subject to reperfused myocardial infarction (MI) and those surviving the MI (n = 16) underwent CMR at 7 days and 8 weeks and then euthanized. Both in patients and animals, T2* of IMH and volume of IMH were determined using ssT2* and aT2* < 20 ms. In animals, ex-vivo T2* CMR and mass spectrometry for iron concentration ([Fe]Hemo) were determined on excised myocardial sections. T2* values based on ssT2* and absolute T2* threshold approaches were independently regressed against [Fe]Hemo and compared. A range of T2* cut-offs were tested to determine the optimized conditions relative to ssT2*. While both approaches showed many similarities, there were also differences. Compared to ssT2*, aT2* < 20 ms showed lower T2* and volume of IMH in patients and animals independent of MI age (all p < 0.005). While T2* determined from both methods were highly correlated against [Fe]Hemo (R2 = 0.9 for both), the slope of the regression curve for ssT2* was significantly larger as compared to aT2* < 20 ms (0.46 vs. 0.32, p < 0.01). Further, slightly larger absolute T2* cut-offs (patients: 23 ms; animals: 25 ms) showed similar IMH characteristics compared to ssT2*. Current quantification methods have excellent capacity to identify IMH, albeit the T2*of IMH and volume of IMH based on aT2* < 20 ms are smaller compared to ssT2*. Thus the method used to quantify IMH from T2* CMR may influence the diagnosis for IMH.

16 August 2021 in Journal of Clinical Investigation
Verified
Journal Article
Closed access
PDF file
SSSheng-Fang Su
Sheng-Fang Su
HHHao Ho
Hao Ho
JLJia-Hua Li
Jia-Hua Li
MWMing-Fang Wu
Ming-Fang Wu
HWHsu-Chieh Wang
Hsu-Chieh Wang
KLKer-Chau Li
Ker-Chau Li
Unlike the better-studied aberrant epigenome in the tumor, the clinicopathologic impact of DNA methylation in the tumor microenvironment (TME), especially the contribution from cancer-associated fibroblasts (CAFs), remains elusive. CAFs exhibit profound patient-to-patient tumorigenic heterogeneity. We asked whether such heterogeneity may be exploited to quantify the level of TME malignancy. We developed a robust and efficient methylome/transcriptome co-analytical system for CAFs and paired normal fibroblasts (NFs) from non–small-cell lung cancer patients. We found 14,781 CpG sites of CAF/NF differential methylation, of which 3,707 sites showed higher methylation changes in ever-smokers than in nonsmokers. Concomitant CAF/NF differential gene expression analysis pointed to a subset of 54 smoking-associated CpG sites with strong methylation-regulated gene expression. A methylation index that summarizes the β values of these CpGs was built for NF/CAF discrimination (MIND) with high sensitivity and specificity. The potential of MIND in detecting premalignancy across individual patients was shown. MIND succeeded in predicting tumor recurrence in multiple lung cancer cohorts without reliance on patient survival data, suggesting that the malignancy level of TME may be effectively graded by this index. Precision TME grading may provide additional pathological information to guide cancer prognosis and open up more options in personalized medicine.

1 December 2024 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
YHYuheng Huang
Yuheng Huang
XGXingmin Guan
Xingmin Guan
XZXinheng Zhang
Xinheng Zhang
GYGhazal Yoosefian
Ghazal Yoosefian
HHHao Ho
Hao Ho
HYHsin-Jung Yang
Hsin-Jung Yang
Free-running cardiac quantitative susceptibility mapping allows for accurate detection and quantification of intramyocardial hemorrhage in the setting of acute myocardial infarction.

11 June 2025 in eLife
Verified
Journal Article
Open access
CHChen-Wei Hsu
Chen-Wei Hsu
HHHao Ho
Hao Ho
CYChing-Hsin Yang
Ching-Hsin Yang
YWYan-Wei Wang
Yan-Wei Wang
KLKer-Chau Li
Ker-Chau Li
BCBon-chu Chung
Bon-chu Chung
Zebrafish is an important organism for genetic studies, but its early germ cell types and the mechanism of sex differentiation have not been fully characterized. Here, we profiled single-cell transcriptomes and charted a developmental trajectory going from germline stem cells, through early, committed, and late progenitors, to premeiotic and meiotic cells. We showed that the transcription factor Foxl2l was expressed in the progenitor, directing progenitor differentiation toward oocytes. CRISPR-Cas9-mediated mutation of foxl2l produced 100% male fish with normal fertility. Another single-cell profiling of foxl2l-/- germ cells revealed the arrest of germ cell development at the stage of progenitor commitment. Concomitantly, nanos2 transcript (germline stem cell marker) was elevated together with an increase of nanos2+ germ cells in foxl2l mutants, indicating the acquisition of a novel stem cell state. Thus, we have identified developmental stages of germ cells in juvenile zebrafish and demonstrated that zebrafish Foxl2l drives progenitor germ cells toward feminization and prevents them from expressing nanos2.

20 August 2023 in Lung Cancer
Verified
Journal Article
Closed access
HHHao Ho
Hao Ho
SYSung-Liang Yu
Sung-Liang Yu
HCHsuan-Yu Chen
Hsuan-Yu Chen
SYShin-Sheng Yuan
Shin-Sheng Yuan
KSKang-Yi Su
Kang-Yi Su
KLKer-Chau Li
Ker-Chau Li

25 March 2026 in Science Translational Medicine
Verified
Journal Article
Closed access
LHLi-Ting Huang
Li-Ting Huang
CYChia-Chi Yang
Chia-Chi Yang
GWGuan Wang
Guan Wang
HZHenghui Zhang
Henghui Zhang
RZRanran Zhang
Ranran Zhang
HYHsin-Jung Yang
Hsin-Jung Yang
Relentless mechanical work of the heart is powered by continuous oxygen consumption. How the heart uses oxygen is a defining feature of its health. Invasive studies have established that impaired oxygen consumption by the myocardium predicts contractile dysfunction and adverse outcomes. Despite its importance, noninvasive quantification of myocardial oxygen use remains limited. Magnetic resonance imaging (MRI) signal is known to be sensitive to blood oxygenation and has the potential to quantify myocardial oxygen consumption noninvasively, without exogenous contrast agents and free of ionizing radiation. However, its clinical translation has been impeded by the need for complex biophysical calibration, vulnerability to imaging artifacts and consistent vital motions, and the requirement of lengthy acquisition times. Here, we introduce a rapid, self-calibrated cardiac MRI framework that overcomes these barriers through high-resolution, motion-resolved coronary sinus oximetry, which can quantify myocardial oxygen extraction of the whole heart within 3 minutes. We optimized the imaging parameters via numerical simulations and validated them against invasive coronary sinus catheterization in a porcine model. We combined the method with clinical MRI sequences and demonstrated the feasibility of quantifying myocardial oxygen consumption and myocardial oxygen efficiency in patients with and without heart failure secondary to myocardial infarction in a single institution. This needle-free approach establishes a practical framework for noninvasive characterization of myocardial oxygen metabolism. It holds the potential to facilitate early disease detection, inform personalized therapeutic strategies, and guide the development of cardiometabolic therapies aimed at addressing the ongoing heart failure epidemic.