Habib Muhammad Nazir Ahmad

Habib Muhammad Nazir Ahmad

Auto-generated profile, based on publicly available information

Habib Muhammad Nazir Ahmad

Department of Electrical and Electronic Engineering, American International University - Bangladesh, Dhaka, Bangladesh

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2019 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
HAHabib M. N. Ahmad
Habib M. N. Ahmad
SGSujoy Ghosh
Sujoy Ghosh
Gaurab DuttaGaurab Dutta
Gaurab Dutta
AMAlec G. Maddaus
Alec G. Maddaus
JTJohn G. Tsavalas
John G. Tsavalas
Edward SongEdward Song
Edward Song

1 September 2011 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
HAHabib Ahmad
Habib Ahmad
ASAlex Sutherland
Alex Sutherland
YSYoung Shik Shin
Young Shik Shin
KHKiwook Hwang
Kiwook Hwang
LQLidong Qin
Lidong Qin
JHJames R. Heath
James R. Heath
Microfluidics flow-patterning has been utilized for the construction of chip-scale miniaturized DNA and protein barcode arrays. Such arrays have been used for specific clinical and fundamental investigations in which many proteins are assayed from single cells or other small sample sizes. However, flow-patterned arrays are hand-prepared, and so are impractical for broad applications. We describe an integrated robotics/microfluidics platform for the automated preparation of such arrays, and we apply it to the batch fabrication of up to eighteen chips of flow-patterned DNA barcodes. The resulting substrates are comparable in quality with hand-made arrays and exhibit excellent substrate-to-substrate consistency. We demonstrate the utility and reproducibility of robotics-patterned barcodes by utilizing two flow-patterned chips for highly parallel assays of a panel of secreted proteins from single macrophage cells.

1 June 2019 in International Conference on Solid State Sensors and Actuators (transducers)
Verified
Conference Paper
Closed access
HAHabib M. N. Ahmad
Habib M. N. Ahmad
BSBo Si
Bo Si
Gaurab DuttaGaurab Dutta
Gaurab Dutta
JCJohn R. Csoros
John R. Csoros
WSWilliam Rudolf Seitz
William Rudolf Seitz
Edward SongEdward Song
Edward Song
We present a novel electrochemical biosensing platform for the detection of neurotransmitter glutamate using templated polymer-based target receptors. Our sensing approach demonstrates, for the first time, a nonenzymatic approach without the need of glutamate oxidase, leading to a more specific and rapid response. The proposed detection principle is based on the following two claims: (1) our templated polymer-based receptor results in specific molecular recognition of the target glutamate and, (2) upon target binding, the polymer undergoes a conformation change which can then be measured via electrochemical techniques. This sensing platform has the potential to provide direct monitoring of a variety of nonelectroactive species and to eliminate the incorporation of enzymes thereby providing a simpler and more robust alternative to enzyme-based sensors.

1 March 2012
Verified
Conference Paper
Closed access
SBSyed Mustafa Khelat Bari
Syed Mustafa Khelat Bari
SBSubrata Biswas
Subrata Biswas
AAA.K.M. Arifuzzman
A.K.M. Arifuzzman
HAHabib Muhammad Nazir Ahmad
Habib Muhammad Nazir Ahmad
NHNawjif Md. Anamul Hasan
Nawjif Md. Anamul Hasan
The main objective of this paper is to design a novel threshold voltage detector circuit using carbon nanotube field effect transistor (CNTFET). This circuit is simulated in HSPICE by using HSPICE model of CNTFET. The uniqueness of this proposed circuit is that the threshold voltage of each CNTFET decides each voltage detection level where as in CMOS implementation a complex band-gap reference circuit is needed to produce a reference voltage level for precise detection. MOSFETs with different threshold voltage can also be used to implement this idea but that would add a new Vth mask for each different voltage detection level which will increase the process cost significantly. Therefore this new proposed CNTFET based voltage level detection circuit can produce much improved performance with significant reduction in implementation complexity by both saving number of mask set and reducing the chip area significantly.

1 August 2014
Verified
Conference Paper
Closed access
HAHabib Muhammad Nazir Ahmad
Habib Muhammad Nazir Ahmad
MIMohammad Shafquatul Islam
Mohammad Shafquatul Islam
KJKazi Muhammad Jameel
Kazi Muhammad Jameel
AOArman Riaz Ochi
Arman Riaz Ochi
RHRakibul Hafiz
Rakibul Hafiz
This manuscript reports and analyzes 12-CNTFET and GDI CNTFET based full adder implementation at 32 nm level. As figures of merit, stability, power dissipation and Power Delay Product (PDP) are considered for the best overall performance. Intensive HSPICE simulations have been performed to investigate the distribution of the power and delay of the CNTFET-based full adders. Both circuit has noticeable reduction in short current power consumption but in terms of comparison GDI CNTFET shows better performance in both power consumption and Power Delay Product (PDP) variations. The CNTFET-based One bit Full Adder cell demonstrates that it tolerates the PVT (Process, Voltage, and Temperature) variations significantly better than its CMOS counterpart.

1 August 2014
Verified
Conference Paper
Closed access
HAHabib Muhammad Nazir Ahmad
Habib Muhammad Nazir Ahmad
KJKazi Muhammad Jameel
Kazi Muhammad Jameel
MIMohammad Shafquatul Islam
Mohammad Shafquatul Islam
AOArman Riaz Ochi
Arman Riaz Ochi
RHRakibul Hafiz
Rakibul Hafiz
This paper proposes a new design technique of a stable, low input impedance, high sensitivity, high gain and low-power Potentiostat using carbon nanotube FETs (CNTFETs) at 32 nm level that utilizes different input voltages for verifying voltage follower performance. The fully differential architecture suppresses the common mode interference. Extensive simulations have been performed to investigate the distribution of the power and delay of the CNTFET-based Potentiostat due to variations in the supply voltage and temperature of the CNTFETs. The CNTFET-based Potentiostat demonstrates that it tolerates the PVT (Process, Voltage, and Temperature) variations significantly better than its CMOS counterpart.