1 January 2020 in Journal of Cardiovascular Magnetic Resonance
Although the breath-hold cine balanced steady state free precession (bSSFP) imaging is well established for assessment of biventricular volumes and function, shorter breath-hold times or no breath-holds are beneficial in children and severely ill or sedated patients. Clinical cardiovascular magnetic resonance (CMR) examinations from September 2019 to October 2019 that included breath-hold (BH) and free-breathing (FB) cine bSSFP imaging accelerated using compressed sensitivity encoding (C-SENSE) factor of 3 in addition to the clinical standard BH cine bSSFP imaging using SENSE factor of 2 were analyzed retrospectively. Patients with structurally normal hearts who could perform consistent BHs were included. Aortic flow measured by phase contrast acquisition was used as a reference for the left ventricular (LV) stroke volume. Comparative analysis was performed for evaluation of biventricular volumes and function, imaging times, quantitative image quality, and qualitative image scoring. There were 26 patients who underwent all three cine scans during the study period (16.7 ± 6.4 years, body surface area (BSA) 1.6 ± 0.4 m2, heart rate 83 ± 7 beats/min). BH durations of 8 ± 1 s with C-SENSE = 3 were significantly shorter (p < 0.001) by 33% compared to 12 ± 1 s with SENSE = 2. Actual scan time for BH SENSE (4.9 ± 1.2 min) was comparable to that with FB C-SENSE (5.2 ± 1.5 min; p= NS). Biventricular stroke volume and ejection fraction, and LV mass computed using all three sequences were comparable. There was a small but statistically significant (p < 0.05) difference in LV end-diastolic volume (− 3.0 ± 6.8 ml) between BH SENSE and FB C-SENSE. There was a small but statistically significant (p < 0.005) difference in end-diastolic LV (− 5.0 ± 7.7 ml) and RV (− 6.0 ± 8.5 ml) volume and end-systolic LV (− 3.2 ± 4.3 ml) and RV(− 4.2 ± 6.8 ml) volumes between BH C-SENSE and FB C-SENSE. The LV stroke volumes from all three sequences had excellent correlations (r = 0.96, slope = 0.98–1.02) with aortic flow, with overestimation by 2.7 (5%) to 4.6 (8%) ml/beat. The image quality score was Excellent (16 of 26) to Good (10 of 26) with BH SENSE, Excellent (13 of 26) to Good (13 of 26) with BH C-SENSE, and Excellent (3 of 26) to Good (21 of 26) to Adequate (2 of 26) with FB C-SENSE. Image quality and ventricular volumetric and functional indices using either BH or FB C-SENSE cine bSSFP imaging were comparable to standard BH SENSE cine bSSFP imaging while maintaining nominally identical spatio-temporal resolution. This accelerated image acquisition provides an alternative to accommodate patients with impaired BH capacity.
1 September 2004 in Journal of Computer Assisted Tomography
To describe magnetic resonance (MR) imaging features of patients with a histologic diagnosis of idiopathic granulomatous mastitis (IGM). Dynamic contrast-enhanced MR imaging was performed with a 1.5-T MR unit. Postprocessing of images included subtraction and calculation of time-intensity curves of the enhancing regions at several points in all patients. In addition to granulomatous inflammation, biopsy slides of 5 patients demonstrated abscess formation without a specific organism (aseptic abscess). One patient had a fibrotic tissue component. Magnetic resonance imaging findings were heterogeneously enhancing areas with (n = 5) and without (n = 1) multiple ring-like enhanced abscesses and a circumscribed lesion with heterogeneous contrast enhancement (n = 1). Time-intensity curves showed a benign pattern in all but 1 patient. Idiopathic granulomatous mastitis has a number of appearances on MR imaging. Magnetic resonance imaging with measurement of time-signal intensity curves may support the findings of ultrasonography and mammography in distinguishing benign inflammatory breast disorders from malignant ones; however, biopsy still remains the only method of definite diagnosis.
1 April 2009 in Magnetic Resonance Imaging
1 June 2010 in Magnetic Resonance Imaging
1 September 2006 in Acta Radiologica
Purpose: To determine the added value of multidetector computed tomography (MDCT)-assisted virtual bronchoscopy (VB) to axial MDCT and multiplanar reformatted (MPR) imaging with respect to conventional bronchoscopy in the evaluation of children with suspected foreign-body aspiration (FBA). Material and Methods: Twenty-one consecutive children (14 male, seven female, age 8 months–7 years, mean age 3.5 years) presenting with the suspicion of FBA were examined with 16-slice MDCT using 100–120 kV, 30–50 mA, 1-mm section thickness, 1.2 pitch ratio, and 0.6–1.0-mm reconstruction interval. Before CT examinations, chest radiographies were also obtained in all cases. VB and MPR imaging were carried out after MDCT examinations. Results: Nine foreign bodies were identified by gold-standard conventional bronchoscopy. VB, thin-section axial MDCT, and MPR images identified eight of nine foreign bodies. CT scans with MPR images and VB did not reveal a chronic foreign body; and, in one patient, endobronchial mucous was diagnosed as the foreign body. The sensitivity, specificity, and accuracy of thin-section axial MDCT and MPR images alone in the diagnosis of FBA were 88.9%, 91.7%, and 90.5%, respectively. Results were the same as those obtained when VB was also included. Conclusion: MDCT with VB and axial/MPR images provide equally valuable information in children with suspected foreign-body aspiration and prevent unnecessary conventional bronchoscopic examinations. However, VB increases total examination time and cost, and it does not provide additional information over MPR images in the evaluation of foreign-body aspiration.