Xuping Yang

Xuping Yang

Auto-generated profile, based on publicly available information

Xuping Yang

College of Electronics and Information Engineering, Sichuan University, Chengdu 610065, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
LYliping yan
liping yan
LXLiuliu Xu
Liuliu Xu
RGRichard Xian-Ke Gao
Richard Xian-Ke Gao
JZJinghan Zhang
Jinghan Zhang
XYXuping Yang
Xuping Yang
XZXiang Zhao
Xiang Zhao
A distinctive frequency selective surface (FSS) to effectively enhance the electromagnetic shielding performance of high-speed electronic systems while preserving good mechanical ventilation is proposed in this article. The FSS consists of periodic segmented circular patterns in two-dimensional view and hollow vent holes in spatial, which exhibits a wide 2 GHz stopband at the interested frequency of 28 GHz. The new design also demonstrates stability to wave oblique incidence and polarization. The FSS shielding panel is prototyped and measured for validation. A satisfactory agreement between simulation and physical experiment is achieved.

9 December 2022 in International Journal of Antennas and Propagation
Verified
Journal Article
Open access
PDF file
FSFeng Shi
Feng Shi
LYliping yan
liping yan
XYXuping Yang
Xuping Yang
XZXiang Zhao
Xiang Zhao
RGRichard Xian-Ke Gao
Richard Xian-Ke Gao
The measurement of radiated emission (RE) in an anechoic chamber becomes very challenging at high frequencies, up to 60 GHz, because the scanning plane of the receiver is in measurement standard deviation from the actual wavefront. As a result, the RE intensity of the devices may be underestimated, resulting in electromagnetic interference. The deviation between the electric field at the far-field vertical scanning point and the actual wavefront is researched. Then, in an anechoic chamber, a hybrid deep learning amendment model of convolutional neural network (CNN) and transformer is proposed to correct the RE measurement at a 3 m distance. The results indicate that the correction is reliable, with an average error of 6.35% for a 3 m distance in a semianechoic chamber and less than 4.83% for other test scenarios. The proposed method provides a promising solution for RE measurement at a millimeter wave band in an anechoic chamber.