Sourav Mukherjee

Sourav Mukherjee

Auto-generated profile, based on publicly available information

Sourav Mukherjee

Department of Chemical Engineering, Indian Institute of Technology Bombay, Mumbai 400076, India

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2024 in Journal of Tissue Engineering and Regenerative Medicine
Verified
Journal Article
Open access
PDF file
RJRohit Joshi
Rohit Joshi
TSTejas Yuvaraj Suryawanshi
Tejas Yuvaraj Suryawanshi
SMSourav Mukherjee
Sourav Mukherjee
Shobha ShuklaShobha Shukla
Shobha Shukla
AMAbhijit Majumder
Abhijit Majumder
Human mesenchymal stem cells (hMSCs) are multipotent cells that differentiate into adipocytes, chondrocytes, and osteoblasts. Owing to their differentiation potential, hMSCs are among the cells most frequently used for therapeutic applications in tissue engineering and regenerative medicine. However, the number of cells obtained through isolation alone is insufficient for hMSC-based therapies and basic research, which necessitates in vitro expansion. Conventionally, this is often performed on rigid surfaces such as tissue culture plates (TCPs). However, during in vitro expansion, hMSCs lose their proliferative ability and multilineage differentiation potential, rendering them unsuitable for clinical use. Although multiple approaches have been attempted to maintain hMSC stemness during prolonged expansion, finding a suitable culture system remains an unmet need. Recently, a few research groups have shown that hMSCs maintain their stemness over long passages when cultured on soft substrates. In addition, it has been shown that hMSCs cultured on soft substrates have more condensed chromatin and lower levels of histone acetylation compared to those cultured on stiff substrates. Furthermore, it has also been shown that condensing/decondensing chromatin by deacetylation/acetylation can delay replicative senescence in hMSCs during long-term expansion on TCPs. However, the mechanism by which chromatin condensation/decondensation influences nuclear morphology and DNA damage, which are strongly related to the onset of senescence, remains unknown. To answer this question, we cultured hMSCs for long duration in the presence of epigenetic modifiers, histone acetyltransferase inhibitor (HATi), which promotes chromatin condensation by preventing histone acetylation, and histone deacetylase inhibitor (HDACi), which promotes chromatin decondensation, and investigated their effects on various nuclear markers related to senescence. We found that consistent acetylation causes severe nuclear abnormalities, whereas chromatin condensation by deacetylation helps to safeguard the nucleus from damage caused by in vitro expansion.

23 February 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
ABAnshul Bhide
Anshul Bhide
SMSourav Mukherjee
Sourav Mukherjee
KGKinjalka Ghosh
Kinjalka Ghosh
AMAbhijit Majumder
Abhijit Majumder
DMDeepak Modi
Deepak Modi
The human placenta functions as a highly specialised barrier that integrates trophoblast differentiation, endocrine activity, and regulated transport of molecules to sustain fetal development. Experimental interrogation of placental barrier function remains challenging due to limited access to human placental tissue and the complexity of existing in vitro models. Here, we report a static, two-chamber placenta-on-chip platform designed to recapitulate key structural and functional attributes of the human placental barrier within an experimentally accessible format. The device design prioritises open maternal compartmentalisation and diffusion-dominated transport, reflecting the haemochorial nature of human placentation. It also remains compatible with standard multi-well plate formats for parallel experimentation. In this two-chambered device, separated by an extracellular matrix-loaded/coated microporous membrane, the trophoblast supports trophoblast syncytialisation, sustained β-human chorionic gonadotropin secretion, and selective barrier function. The engineered barrier restricts macromolecular transport while permitting controlled diffusion of small solutes. Glucose transport across the device is strongly dependent on cellular configuration, with inclusion of the endothelial layer significantly modulating nutrient flux and yielding fetal-to-maternal glucose ratios comparable to those reported in vivo. The platform further supports directional transfer of urea from the fetal to the maternal compartment, demonstrating bidirectional metabolite exchange relevant to placental waste clearance. Under hyperglycemic conditions, glucose transport across the barrier increases without evidence of barrier breakdown, indicating sensitivity to metabolic perturbation. This scalable design of a placenta-on-chip platform provides a robust framework for studying placental transport, metabolic regulation, and barrier integrity. It offers broad application in placental biology, pregnancy-associated pathologies, and screening for pregnancy-safe drugs.

3 July 2026 in Biofabrication
Verified
Journal Article
Closed access
ABAnshul Bhide
Anshul Bhide
SMSourav Mukherjee
Sourav Mukherjee
KGKinjalka Ghosh
Kinjalka Ghosh
AMAbhijit Majumder
Abhijit Majumder
DMDeepak Modi
Deepak Modi
The human placenta functions as a highly specialised barrier that integrates trophoblast differentiation, endocrine activity, and regulated transport of molecules to sustain fetal development. Experimental interrogation of placental barrier function remains challenging due to limited access to human placental tissue and the complexity of existing in vitro models. Here, we report a static, two-chamber placenta-on-chip platform designed to recapitulate key structural and functional attributes of the human placental barrier within an experimentally accessible format. The device design prioritises open maternal compartmentalisation and diffusion-dominated transport, reflecting the haemochorial nature of human placentation. It also remains compatible with standard multi-well plate formats for parallel experimentation. In this two-chambered device, separated by an extracellular matrix-loaded/coated microporous membrane, the trophoblast supports trophoblast syncytialisation, sustained β -human chorionic gonadotropin secretion, and selective barrier function. The engineered barrier restricts macromolecular transport while permitting controlled diffusion of small solutes. Glucose transport across the device is strongly dependent on cellular configuration, with inclusion of the endothelial layer significantly modulating nutrient flux and yielding fetal-to-maternal glucose ratios comparable to those reported in vivo . The platform further supports directional transfer of urea from the fetal to the maternal compartment, demonstrating bidirectional metabolite exchange relevant to placental waste clearance. Under hyperglycemic conditions, glucose transport across the barrier increases without evidence of barrier breakdown, indicating sensitivity to metabolic perturbation. This scalable design of a placenta-on-chip platform provides a robust framework for studying placental transport, metabolic regulation, and barrier integrity. It offers broad application in placental biology, pregnancy-associated pathologies, and screening for pregnancy-safe drugs.

3 June 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
PMPankaj Mogha
Pankaj Mogha
SMSourav Mukherjee
Sourav Mukherjee
TGTushar Gangwar
Tushar Gangwar
DRDebjyoti Roy
Debjyoti Roy
AVAditi Vichare
Aditi Vichare
AMAbhijit Majumder
Abhijit Majumder
3D spheroids, which closely replicate three-dimensional cell-cell and cell-extracellular matrix interactions, offer superior predictive capabilities compared to conventional 2D monolayer cultures, positioning them as forward-looking platforms in drug testing, cancer biology, and regenerative medicine. However, high-throughput generation of uniform sized spheroids is still a technological challenge. In one hand, the use of conventional ultra-low attachment (ULA) multiwell plates for this purpose is labour intensive and complex. On the other hand, the use of microfabricated facilities demands cutting-edge infrastructure such as clean room, photolithography, and microfluidic setup which are often unavailable for the resource constrained laboratories. In this study, we addressed these problems by developing a low-cost Do-It-Yourself (DIY), polydimethylsiloxane (PDMS) and agarose-based spheroid generation device, capable of producing and maintaining hundreds of spheroids with minimal user intervention. We have demonstrated two variants based on their size, termed here as S1 and S2 devices which fit into 6-well and 12-well plates, and can generate 600 and 1200 uniform-sized spheroids respectively. We validated our device with various cell lines including primary and cancerous cell lines. We further demonstrated the drug testing capabilities of the device by estimating the IC 50 value of the anticancer drug Temozolomide on U87-MG. The value was comparable with the same obtained from the spheroids generated using conventional ULA plates. Additional attachment of a perfusion system made the device suitable for long-term spheroid culture without much user intervention. Furthermore, the devices can also be used for the production of spheroids with gradually changing diameters in a controlled manner, resembling a size gradient. This feature is useful for checking the effect of drugs on different-sized spheroids and for co-culturing spheroids with varying cell densities, mimicking the disease architecture. We have co-cultured two types of the placental trophoblast cells, i.e., extravillous trophoblast (HTR-8) and syncytiotrophoblast (BeWo) with varying densities. In summary, this paper demonstrates a unique DIY method for a high-throughput uniform-sized spheroid generation at a fraction of cost which can be deployed to resource-constrained labs.

31 July 2026 in Biofabrication
Verified
Journal Article
Closed access
PDF file
PMPankaj Mogha
Pankaj Mogha
SMSourav Mukherjee
Sourav Mukherjee
TGTushar Gangwar
Tushar Gangwar
DRDebjyoti Roy
Debjyoti Roy
AVAditi Vichare
Aditi Vichare
AMAbhijit Majumder
Abhijit Majumder
3D spheroids, which closely replicate three-dimensional cell–cell and cell-extracellular matrix interactions, offer superior predictive capabilities compared to conventional 2D monolayer cultures, positioning them as forward-looking platforms in drug testing, cancer biology, and regenerative medicine. However, high-throughput generation of uniform sized spheroids is still a technological challenge. In one hand, the use of conventional ultra-low attachment (ULA) multiwell plates for this purpose is labor intensive and complex. On the other hand, the use of microfabricated facilities demands cutting-edge infrastructure such as clean room, photolithography, and microfluidic setup which are often unavailable for the resource constrained laboratories. In this study, we addressed these problems by developing a low-cost do-it-yourself (DIY), polydimethylsiloxane (PDMS) and agarose-based spheroid generation device, capable of producing and maintaining hundreds of spheroids with minimal user intervention. We have demonstrated two variants based on their size, termed here as S1 and S2 devices which fit into 6-well and 12-well plates, and can generate 600 and 1200 uniform-sized spheroids respectively. We validated our device with various cell lines including primary and cancerous cell lines. We further demonstrated the drug testing capabilities of the device by estimating the IC 50 value of the anticancer drug Temozolomide on U87-MG. The value was comparable with the same obtained from the spheroids generated using conventional ULA plates. Additional attachment of a perfusion system made the device suitable for long-term spheroid culture without much user intervention. Furthermore, the devices can also be used for the production of spheroids with gradually changing diameters in a controlled manner, resembling a size gradient. This feature is useful for checking the effect of drugs on different-sized spheroids and for co-culturing spheroids with varying cell densities, mimicking the disease architecture. We have co-cultured two types of the placental trophoblast cells, i.e. extravillous trophoblast (HTR-8) and syncytiotrophoblast (BeWo) with varying densities. In summary, this paper demonstrates a unique DIY method for a high-throughput uniform-sized spheroid generation at a fraction of cost which can be deployed to resource-constrained labs.