Matthias Müller

Matthias Müller

Auto-generated profile, based on publicly available information

Matthias Müller

Laser-Lab. Göttingen e.V. (Germany)

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
MMMatthias Müller
Matthias Müller
TMTobias Mey
Tobias Mey
JNJürgen Niemeyer
Jürgen Niemeyer
KMKlaus Mann
Klaus Mann
An extremely compact soft x-ray microscope operating in the “water window” region at the wavelength λ = 2.88 nm is presented, making use of a long-term stable and nearly debris-free laser-induced plasma from a pulsed nitrogen gas jet target. The well characterized soft x-ray radiation is focused by an ellipsoidal grazing incidence condenser mirror. Imaging of a sample onto a CCD camera is achieved with a Fresnel zone plate using magnifications up to 500x. The spatial resolution of the recorded microscopic images is about 100 nm as demonstrated for a Siemens star test pattern.

18 February 2016 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MNMartin Nikl
Martin Nikl
VBVladimir Babin
Vladimir Babin
JPJan Pejchal
Jan Pejchal
VLValentyn Laguta
Valentyn Laguta
MBMaksym Buryi
Maksym Buryi
MMMatthias Muller
Matthias Muller
The role and effect of stable Ce 4+ centers in Ce-doped LuAG single crystal scintillator is further studied by means of measurements of several optical, luminescence and scintillation characteristics. Two LuAG:Ce single crystal samples are compared: in one of them the dominating Ce 4 + center is stabilized by high concentration Mg 2+ codoping while the other one shows only the presence of stable Ce 3 + center. Tailored (Eu, Mg)-doped LuAG single crystal is also prepared to test the presence and thermal stability of hole traps in the host which affect the timing characteristics of Ce 4+ scintillation cycle, namely its restoration back to 4+ charge state in last step of the cycle. EPR experiment was also employed at Mg- and (Eu, Mg) doped LuAG samples and the signature of the O - hole center stabilized by Mg 2 + ion was clearly obtained.

17 May 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
MMMatthias Müller
Matthias Müller
FKFrank-Christian Kühl
Frank-Christian Kühl
PGPeter Großmann
Peter Großmann
PVPavel Vrba
Pavel Vrba
KMKlaus Mann
Klaus Mann
The influcence of the pulse duration on the emission characteristics of nearly debris-free laser-induced plasmas in the soft x-ray region (λ ≈1-5 nm) was investigated, using six different target gases from a pulsed jet. Compared to ns pulses of the same energy, a ps laser generates a smaller, more strongly ionized plasma, being about 10 times brighter than the ns laser plasma. Moreover, the spectra are considerably shifted towards shorter wavelengths. Electron temperatures and densities of the plasma are obtained by comparing the spectra with model calculations using a magneto-hydrodynamic code.

16 May 2016 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Closed access
PDF file
FKFrank-Christian Kühl
Frank-Christian Kühl
MMMatthias Müller
Matthias Müller
MSMeike Schellhorn
Meike Schellhorn
KMKlaus Mann
Klaus Mann
SWStefan Wieneke
Stefan Wieneke
KEKarin Eusterhues
Karin Eusterhues
The authors present a table-top soft x-ray absorption spectrometer, accomplishing investigations of the near-edge x-ray absorption fine structure (NEXAFS) in a laboratory environment. The system is based on a low debris plasma ignited by a picosecond laser in a pulsed krypton gas jet, emitting soft x-ray radiation in the range from 1 to 5 nm. For absorption spectroscopy in and around the “water window” (2.3–4.4 nm), a compact helium purged sample compartment for experiments at atmospheric pressure has been constructed and tested. NEXAFS measurements on CaCl2 and KMnO4 samples were conducted at the calcium and manganese L-edges, as well as at the oxygen K-edge in air, atmospheric helium, and under vacuum, respectively. The results indicate the importance of atmospheric conditions for an investigation of sample hydration processes.

10 April 2019 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
JHJonathan Holburg
Jonathan Holburg
MMMatthias Müller
Matthias Müller
KMKlaus Mann
Klaus Mann
SWStephan Wieneke
Stephan Wieneke
Two methods improving the brilliance of laser-induced plasmas emitting in the extreme UV (EUV) and soft x-ray (SXR) regions were investigated, using three different gases (nitrogen, krypton, and xenon) from a pulsed gas jet. Utilizing a newly designed piezoelectric valve, up to almost ten times higher gas pressures were applied, resulting in increased target densities and thus, higher conversion efficiencies of laser energy into EUV and SXR radiation. Secondly, geometrically reducing the angle between the incoming laser beam and the observed plasma emission minimizes reabsorption of the emitted short wavelength radiation. Combining both methods, the source brilliance is increased by a factor of 5 for nitrogen. Furthermore, a compact EUV focusing system for metrological applications is presented utilizing the optimized plasma source. An energy density of 1 mJ/cm2 at wavelength λ = 13.5 nm in the focal spot of an ellipsoidal mirror is achieved with xenon as the target gas being sufficient for material removal of PMMA samples with an ablation rate of 0.05 nm/pulse.

10 July 2012 in Applied Physics A
Verified
Journal Article
Open access
PDF file
MMMatthias Müller
Matthias Müller
FBFrank Barkusky
Frank Barkusky
TFTorsten Feigl
Torsten Feigl
KMKlaus Mann
Klaus Mann
We present 1-on-1 and 10-on-1 damage threshold investigations on Mo/Si multilayers with EUV radiation of 13.5 nm wavelength, using a table-top laser produced plasma source based on solid gold as target material. The experiments were performed on different types of Mo/Si mirror, showing no significant difference in single pulse damage thresholds. However, the damage threshold for ten pulses is ≈60 % lower than the single pulse threshold, implying a defect dominated damage process. Using Nomarski (DIC) and atomic force microscopy (AFM) we analysed the damage morphologies, indicating a primarily thermally induced damage mechanism. Additionally, we studied the radiation-induced change of reflectivity upon damage of a multilayer mirror.