26 March 2026 in Scientific Reports
Verified
Journal Article
Open access
ADArmin Doostparast
Armin Doostparast
FSFarbod Semnani
Farbod Semnani
MGMaryam Ghandhari
Maryam Ghandhari
MGMohammadreza Ghandhari
Mohammadreza Ghandhari
AKAmir Hossein Khosronejad
Amir Hossein Khosronejad
AEAlireza Eslampoor
Alireza Eslampoor
We aimed to evaluate the absolute agreement, consistency, and the potential of arithmetic adjustment for measurements across a swept-source optical coherence tomography biometer (IOLMaster 700), a single Scheimpflug-based tomographer (Pentacam HR), and a combined Scheimpflug-Placido disc-based tomographer (Sirius). This cross-sectional study analyzed the corneal keratometry parameters (Sim-K1, Sim-K2, and Sim-Km, corneal astigmatism (CA), and its Jackson power vectors (J0 and J45), central corneal thickness (CCT), anterior chamber depth (ACD), and the horizontal white-to-white distance (WTW) of 111 healthy eyes. The inter-device agreement was assessed using the Bland-Altman limits of agreement (LoA) and two types of intraclass correlation coefficient (ICC) analyses. A mean difference (MD) translating to less than 0.25D in refractive outcomes was considered clinically acceptable. Except for the WTW (ICC(2,1) = 0.52, ICC(3,1) = 0.65), the inter-device agreement was excellent for all parameters (ICC(2,1) and ICC(3,1) > 0.90), with the CA and its power vectors (ICC(2,1) and ICC(3,1): 0.87–0.90) being slightly inferior. WTW values varied substantially across devices, but applying a constant adjustment (MD = 0.36) between Pentacam HR and Sirius improved agreement (ICC(2,1) rising from 0.59 to 0.90), whereas adjustment was not feasible with IOLMaster 700. CCT and ACD may be considered interchangeable across the three, particularly in intraocular lens (IOL) power calculation (the widest LoA were − 0.20 to 0.16 mm for ACD and − 10.99 to 25.42 μm for CCT, respectively). Keratometry values exhibited clinically relevant LoA (the widest LoA for Sim-Km: − 0.77 to 0.80 diopters), limiting their direct interchangeability. Although WTW showed the greatest variability (the widest LoA: − 0.86 to 0.64 mm), the agreement between Pentacam HR and Sirius could be improved through an arithmetic adjustment. This adjustment indicated a systematic error rather than random variability between Pentacam HR and Sirius. These findings highlight the potential of arithmetic adjustment of WTW, an important variable in implantable collamer lens sizing, similar to constant optimization in the IOL power formulas.

14 February 2026 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Open access
ADArmin Doostparast
Armin Doostparast
FSFarbod Semnani
Farbod Semnani
MGMaryam Ghandhari
Maryam Ghandhari
MGMohammadreza Ghandhari
Mohammadreza Ghandhari
AKAmir Hossein Khosronejad
Amir Hossein Khosronejad
AEAlireza Eslampoor
Alireza Eslampoor
We aimed to compare the anterior corneal aberrometry between Pentacam HR, a Scheimpflug-based imaging system, and Peramis, an aberrometer that combines a pyramidal wavefront sensor with Placido-disk topography. Myopic, otherwise healthy patients who were scheduled for refractive surgery were examined for anterior corneal aberration profiles using Pentacam HR and Peramis in a 4 mm pupil-centered analysis zone. This profile included corneal total aberrations (TAs), lower-order aberrations (LOAs), higher-order aberrations (HOAs), trefoil (Z(3,-3), Z(3,3)), coma (Z(3,-1), Z(3,1)), and spherical aberrations (Z(4,0)). Subgroup analysis was performed according to the laterality of eyes and the severity of myopia. In addition to the root mean square micrometer (RMS µm), the aberrometry data were simultaneously presented as equivalent diopters to facilitate clinical understanding. A difference of less than 0.5 diopter or 0.3 RMS µm was considered clinically interchangeable. A total of 160 eyes from 80 patients were included. Pentacam HR consistently showed significantly higher corneal TAs, LOAs, HOAs, and SA in both eyes (p < 0.01). There was a moderate correlation for corneal TAs, LOAs, and coma aberrations (ICC: 0.39-0.59). In contrast, the correlation was poor for trefoil and spherical aberrations (ICC: 0.16-0.38) and almost non-existent for HOAs (ICC: 0.01-0.07). The width of the 95 % limits of agreement was too large across all comparisons, exceeding 2 RMS µm for TAs and LOAs and 1 RMS µm for HOAs. It was also approximately 0.5 RMS µm for trefoil, coma, and spherical aberrations. Similar patterns were observed in subgroups, regardless of eye laterality or myopia severity. Despite moderate correlations in some Zernike terms, the two systems could not be used interchangeably. This is important in pre-operative planning, where patients with higher HOAs might be/not be candidates for particular cataract or wavefront-based refractive surgeries.