Jai Prakash Saini

Jai Prakash Saini

Auto-generated profile, based on publicly available information

Jai Prakash Saini

Madan Mohan Malaviya University of Technology, Gorakhpur, U.P., India

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RKRajeev Kumar
Rajeev Kumar
SPSarika Pal
Sarika Pal
YPYogendra Kumar Kumar Prajapati
Yogendra Kumar Kumar Prajapati
Santosh KumarSantosh Kumar
Santosh Kumar
JSJ. P. Saini
J. P. Saini
This work presents a surface plasmon resonance (SPR) sensor based on Gallium (Ga)-doped-Zinc oxide (ZnO) and Ti 3 C 2 T x (MXene) for sensitivity enhancement. The smaller resistivity and high conductivity of the pulsed layer deposited Ga-doped-ZnO are used to improve the sensitivity up to (264.59 °/RIU). The detection accuracy (0.1152°) and figure of merit (30.48 RIU −1 ) are also evaluated for the proposed sensor. The effects of using different prisms (SiO 2 , BaF 2 , CsF, and BK7), plasmonic metals (Au, Ag, Cu, and Al) and doping in ZnO (intermediate layer) on the performance parameters of the proposed SPR sensor are investigated for comparative analysis. The comparative performance analysis presents the maximum sensitivity for the SPR sensor structure: Prism SiO 2 /Au/Ga-doped-ZnO/MXene. The field distribution at different layer interfaces of the SPR sensor configurations has also been analyzed using FEM simulations. This work is suitable for the detection of biomolecules and biochemicals

10 July 2020 in Silicon
Verified
Journal Article
Closed access
PDF file
RKRajeev Kumar
Rajeev Kumar
SPSarika Pal
Sarika Pal
YPYogendra Kumar Kumar Prajapati
Yogendra Kumar Kumar Prajapati
JSJ.P. Saini
J.P. Saini

24 September 2020 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
SPSarika Pal
Sarika Pal
AVAlka Verma
Alka Verma
YPYogendra Kumar Kumar Prajapati
Yogendra Kumar Kumar Prajapati
JSJ. P. Saini
J. P. Saini

11 January 2021 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
SRSurjeet Raikwar
Surjeet Raikwar
DSD. K. Srivastava
D. K. Srivastava
JSJ. P. Saini
J. P. Saini
YPYogendra Kumar Kumar Prajapati
Yogendra Kumar Kumar Prajapati

30 June 2020 in IEEE Sensors Letters
Verified
Journal Article
Closed access
MSManeesh Kumar Singh
Maneesh Kumar Singh
SPSarika Pal
Sarika Pal
YPYogendra Kumar Kumar Prajapati
Yogendra Kumar Kumar Prajapati
JSJai Prakash Saini
Jai Prakash Saini
Here, an ultrasensitive SPR sensor based on angular interrogation using antimonene and BlueP/MoS2 heterostructure is proposed. Antimonene is used as interacting layer due to its higher binding energy for analytes than graphene. BlueP/MoS2 enhances sensitivity by manipulating charge transfer to metal/dielectric interface. Sensitivity is analyzed by tuning of heterostructure, antimonene layers and for wide range of analyte refractive index. Highest sensitivity of 198.4/RIU is achieved for three layers of BlueP/MoS2. Results show significant sensitivity for proposed design than conventional and graphene based SPR sensor. Proposed SPR sensor can be successfully developed as SPR chip for biomolecule/analyte detection in visible range.

20 April 2021 in Optical and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
RKRajeev Kumar
Rajeev Kumar
SPSarika Pal
Sarika Pal
NPNarendra Pal
Narendra Pal
AVAlka Verma
Alka Verma
JSJ. P. Saini
J. P. Saini
YPYogendra Kumar Kumar Prajapati
Yogendra Kumar Kumar Prajapati