Thomas Hadler

Thomas Hadler

Auto-generated profile, based on publicly available information

Thomas Hadler

Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, ECRC Experimental and Clinical Research Center, Berlin, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2023 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
THThomas Hadler
Thomas Hadler
CAClemens Ammann
Clemens Ammann
JWJens Wetzl
Jens Wetzl
DVDarian Viezzer
Darian Viezzer
JGJan Wolfgang Gröschel
Jan Wolfgang Gröschel
JSJeanette Schulz-Menger
Jeanette Schulz-Menger
Cardiovascular Magnetic Resonance (CMR) imaging is a growing field with increasing diagnostic utility in clinical routine. Quantitative diagnostic parameters are typically calculated based on contours or points provided by readers, e.g. natural intelligences (NI) such as clinicians or researchers, and artificial intelligences (AI). As clinical applications multiply, evaluating the precision and reproducibility of quantitative parameters becomes increasingly important. Although segmentation challenges for AIs and guidelines for clinicians provide quality assessments and regulation, the methods ought to be combined and streamlined for clinical applications. The goal of the developed software, Lazy Luna (LL), is to offer a flexible evaluation tool that is readily extendible to new sequences and scientific endeavours. An interface was designed for LL, which allows for comparing annotated CMR images. Geometric objects ensure precise calculations of metric values and clinical results regardless of whether annotations originate from AIs or NIs. A graphical user interface (GUI) is provided to make the software available to non-programmers. The GUI allows for an interactive inspection of image datasets as well as implementing tracing procedures, which follow statistical reader differences in clinical results to their origins in individual image contours. The backend software builds on a set of meta-classes, which can be extended to new imaging sequences and clinical parameters. Following an agile development procedure with clinical feedback allows for a quick implementation of new classes, figures and tables for evaluation. Two application cases present LL's extendibility to clinical evaluation and AI development contexts. The first concerns T1 parametric mapping images segmented by two expert readers. Quantitative result differences are traced to reveal typical segmentation dissimilarities from which these differences originate. The meta-classes are extended to this new application scenario. The second applies to the open source Late Gadolinium Enhancement (LGE) quantification challenge for AI developers "Emidec", which illustrates LL's usability as open source software. The presented software Lazy Luna allows for an automated multilevel comparison of readers as well as identifying qualitative reasons for statistical reader differences. The open source software LL can be extended to new application cases in the future.

17 March 2025 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Open access
PDF file
PRPhiline Reisdorf
Philine Reisdorf
JGJonathan Gavrysh
Jonathan Gavrysh
CAClemens Ammann
Clemens Ammann
MFMaximilian Fenski
Maximilian Fenski
CKChristoph Kolbitsch
Christoph Kolbitsch
THThomas Hadler
Thomas Hadler
Cardiovascular magnetic resonance imaging (CMR) offers state-of-the-art myocardial tissue differentiation. The CMR technique late gadolinium enhancement (LGE) currently provides the noninvasive gold standard for the detection of myocardial fibrosis. Typically, thresholding methods are used for fibrotic scar tissue quantification. A major challenge for standardized CMR assessment is large variations in the estimated scar for different methods. The aim was to improve quality assurance for LGE scar quantification, a multi-reader comparison tool “Lumos” was developed to support quality control for scar quantification methods. The thresholding methods and an exact rasterization approach were implemented, as well as a graphical user interface (GUI) with statistical and case-specific tabs. Twenty LGE cases were considered with half of them including artifacts and clinical results for eight scar quantification methods computed. Lumos was successfully implemented as a multi-level multi-reader comparison software, and differences between methods can be seen in the statistical results. Histograms visualize confounding effects of different methods. Connecting the statistical level with the case level allows for backtracking statistical differences to sources of differences in the threshold calculation. Being able to visualize the underlying groundwork for the different methods in the myocardial histogram gives the opportunity to identify causes for different thresholds. Lumos showed the differences in the clinical results between cases with artifacts and cases without artifacts. A video demonstration of Lumos is offered as supplementary material 1. Lumos allows for a multi-reader comparison for LGE scar quantification that offers insights into the origin of reader differences.

26 December 2025 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
HSHadil Saad
Hadil Saad
CAClemens Ammann
Clemens Ammann
THThomas Hadler
Thomas Hadler
YBYashraj Bhoyroo
Yashraj Bhoyroo
PRPhiline Reisdorf
Philine Reisdorf
JSJeanette Schulz-Menger
Jeanette Schulz-Menger
Purpose: To introduce an artificial intelligence-based cardiovascular magnetic resonance segmentation algorithm (Nick) for automated quantification of function and parametric mapping across cardiac phenotypes reflecting clinical routine. Methods: Nick was compared to manual gold standard (GS) segmentations in 359 multi-centre cases at 1.5T and 3T, consisting of 104 healthy individuals and 255 diseased patients with various cardiac phenotypes. Left and right ventricular (LV, RV) volumes and LV mass (LVM) were derived from short-axis segmentations. For parametric mapping, the LV myocardium was segmented to quantify T1 and T2 relaxation times. Statistical analysis comprised mean differences, correlation coefficients (R²), Bland-Altman analysis, tolerance range assessments, and paired boxplots. The number of slices and contours requiring manual correction was estimated based on slice-level differences. Results: Nick demonstrated high agreement with the GS for LV and RV volume estimations (R²≥0.93) and LVM quantification (R²=0.86). For the ejection fractions, correlations were slightly lower (R²=0.85/0.72 for LV/RV) with small mean differences (+ 1.14%/-2.48% for LV/RV). T1 and T2 mapping values showed excellent agreement with manual reference values (R²≥0.92) and minimal biases (-1.64/0.14 ms for T1/T2). Nick underestimated LV volumes at end-diastole (-4.48 ml) and end-systole (-3.28 ml) as well as the RV end-diastolic volume (-5.14 ml) and stroke volume (-6.75 ml). Nonetheless, tolerance testing for mean deviations revealed clinically acceptable biases for all comparisons, and less than two slices per case required correction on average. Conclusion: Comparison to expert segmentations revealed robust performance of Nick in routine clinical cases with variable pathology, supporting its future integration into clinical workflows. Graphical

16 May 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
THThomas Hadler
Thomas Hadler
CAClemens Ammann
Clemens Ammann
HSHadil Saad
Hadil Saad
LGLeonhard Grassow
Leonhard Grassow
PRPhiline Reisdorf
Philine Reisdorf
JSJeanette Schulz-Menger
Jeanette Schulz-Menger
Background: Artificial intelligence (AI) methods have established themselves in cardiovascular magnetic resonance (CMR) as automated quantification tools for ventricular volumes, function, and myocardial tissue characterization. Quality assurance approaches focus on measuring and controlling AI-expert differences but there is a need for tools that better communicate reliability and agreement. This study introduces the Verity plot, a novel statistical visualization that communicates the reliability of quantitative parameters (QP) with clear agreement criteria and descriptive statistics. Methods: Tolerance ranges for the acceptability of the bias and variance of AI-expert differences were derived from intra- and interreader evaluations. AI-expert agreement was defined by bias confidence and variance tolerance intervals being within bias and variance tolerance ranges. A reliability plot was designed to communicate this statistical test for agreement. Verity plots merge reliability plots with density and a scatter plot to illustrate AI-expert differences. Their utility was compared against Correlation, Box and Bland-Altman plots. Results: Bias and variance tolerance ranges were established for volume, function, and myocardial tissue characterization QPs. Verity plots provided insights into statstistcal properties, outlier detection, and parametric test assumptions, outperforming Correlation, Box and Bland-Altman plots. Additionally, they offered a framework for determining the acceptability of AI-expert bias and variance. Conclusion: Verity plots offer markers for bias, variance, trends and outliers, in addition to deciding AI quantification acceptability. The plots were successfully applied to various AI methods in CMR and decisively communicated AI-expert agreement.

1 January 2026 in European Heart Journal - Imaging Methods and Practice
Verified
Journal Article
Open access
PDF file
MFMaximilian Fenski
Maximilian Fenski
RHRichard Hickstein
Richard Hickstein
LKLeo Dyke Krüger
Leo Dyke Krüger
CAClemens Ammann
Clemens Ammann
THThomas Hadler
Thomas Hadler
JSJeanette Schulz-Menger
Jeanette Schulz-Menger
Left atrial (LA) myopathy is a key driver of atrial fibrillation (AF) development and progression. Late gadolinium enhancement (LGE) cardiovascular magnetic resonance enables non-invasive quantification of LA fibrosis, a hallmark of atrial myopathy. However, conventional LGE sequences lack sufficient spatial resolution to accurately depict the thin atrial wall, and reference data in healthy cohorts are scarce. This study aimed to evaluate a high-resolution isotropic 3D LGE Dixon sequence for assessing LA fibrosis in healthy controls and AF patients. In this prospective study, 40 ablation-naïve AF patients (21 paroxysmal, 19 persistent) and 20 healthy controls underwent isotropic (1.3 mm3) 3D whole-heart LGE imaging. Segmentation was successfully performed using CemrgApp in all participants. A setup-specific threshold for fibrosis detection was defined as an image-intensity ratio (IIR) > 1.34 (mean + 2SD of healthy controls) and validated against pre-procedural electroanatomical mapping (EAM) and follow-up imaging at six months post ablation. At baseline, total LA enhancement was higher in persistent than paroxysmal AF (3.65% [1.84–7.16] vs. 1.16% [0.43–2.27]; P = 0.044) and controls (1.25% [0.65–1.75]; P = 0.041). No significant correlation was observed between total LGE-derived fibrosis and bipolar low-voltage area (ρ = −0.03, P = 0.87), though point-by-point analysis showed a weak negative correlation (ρ = −0.05, P < 0.001). In patients with sinus rhythm at follow-up, total fibrosis increased from 1.68% [0.64–6.51] to 6.30% [2.53–12.28]; P < 0.001, driven by peri-ablational scar formation, with no change in remote myocardium. Intra-reader correlation for LA-LGE was excellent: ICC 0.99 (95% CI 0.95–0.99). High resolution isotropic 3D LA-LGE enables robust detection of ablation-induced scarring and biologically plausible fibrosis differences between AF stages. However, its correlation with bipolar voltage mapping remains limited, suggesting that LGE and EAM provide complementary information on atrial myopathy.

2 June 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
THThomas Hadler
Thomas Hadler
CAClemens Ammann
Clemens Ammann
HSHadil Saad
Hadil Saad
YBYashraj Bhoyroo
Yashraj Bhoyroo
JVJana Veit
Jana Veit
JSJeanette Schulz-Menger
Jeanette Schulz-Menger
Automated segmentation of cardiac magnetic resonance (CMR) imaging is integrated into clinical workflows, yet comparative performance across vendor AI solutions remains insufficiently characterized. This study assessed three models (two commercial, one research) for short-axis cine segmentation in a diverse cohort of 346 cases, including dilated cardiomyopathy (DCM), left ventricular hypertrophy (LVH), healthy volunteers, and other cardiac diseases. Clinical parameter agreement between AI-derived and expert-derived ventricular volumes and left ventricular mass (LVM) was evaluated using correlations and mean differences, segmentation agreement with Dice coefficient, and slice detection was characterized with false positive and negative rates (FPR/FNR). Papillary muscle (PM) inclusion was examined with subgroup analyses. AI-derived clinical parameters agreed strongly with expert measurements (r > 0.8). Nevertheless, inter-model biases included differing ventricular volume estimates. Midventricular segmentation was reliable (Dice > 80%), whereas apical slices were poor (Dice < 65%) with minor area impact (< 1cm 2 ). Basal slice detection varied substantially, with AI1 and AI2 over- and AI3 under-detecting slices (e.g. RV FPR: AI1 24%, AI2 14%, AI3 FNR: 32%), producing large area differences. Due to PM exclusion AI2 overestimated volumes and underestimated LVM – particularly LVH-cases. While AI-expert agreement is high, AI solutions are not interchangeable and produce clinically relevant differences to experts across cardiac regions and disease groups.