Edmond Richer

Edmond Richer

Auto-generated profile, based on publicly available information

Edmond Richer

Department of Mechanical Engineering, Southern Methodist University, Dallas, TX, USA

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in 3D Printing and Additive Manufacturing
Verified
Journal Article
Closed access
MSMatt Saari
Matt Saari
BXBin Xia
Bin Xia
BCBryan Cox
Bryan Cox
PKPaul S. Krueger
Paul S. Krueger
ACAdam L. Cohen
Adam L. Cohen
EREdmond Richer
Edmond Richer
Fiber encapsulation additive manufacturing (FEAM) and thermoplastic elastomer additive manufacturing (TEAM) are combined to create a composite capacitive force sensor. This work presents analysis on a capacitive force sensor developed by combining the advantages of FEAM and TEAM. The capacitive sensor consists of a 3D printed rigid frame with embedded wires in a tight spiral pattern that emulates a flat plate capacitor and a thermoplastic elastomer dielectric spacer that compresses under applied force. An approximately linear response for the corresponding capacitance change versus applied load is obtained to evaluate the printed capacitor effectiveness as a force sensor.

1 November 2019 in Mechatronics
Verified
Journal Article
Closed access
AZAmir Hosein Zamanian
Amir Hosein Zamanian
EREdmond Richer
Edmond Richer

9 July 2013 in Diagnostics
Verified
Journal Article
Open access
PDF file
MLMatthew Lewis
Matthew Lewis
EREdmond Richer
Edmond Richer
NSNikolai V. Slavine
Nikolai V. Slavine
VKVikram D. Kodibagkar
Vikram D. Kodibagkar
TSTodd C. Soesbe
Todd C. Soesbe
Ralph MasonRalph Mason
Ralph Mason
Bioluminescent imaging (BLI) of cells expressing luciferase is a valuable noninvasive technique for investigating molecular events and tumor dynamics in the living animal. Current usage is often limited to planar imaging, but tomographic imaging can enhance the usefulness of this technique in quantitative biomedical studies by allowing accurate determination of tumor size and attribution of the emitted light to a specific organ or tissue. Bioluminescence tomography based on a single camera with source rotation or mirrors to provide additional views has previously been reported. We report here in vivo studies using a novel approach with multiple rotating cameras that, when combined with image reconstruction software, provides the desired representation of point source metastases and other small lesions. Comparison with MRI validated the ability to detect lung tumor colonization in mouse lung.

15 October 2007 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
TSTodd C. Soesbe
Todd C. Soesbe
MLMatthew Lewis
Matthew Lewis
EREdmond Richer
Edmond Richer
NSNikolai V. Slavine
Nikolai V. Slavine
PAPeter P. Antich
Peter P. Antich
The electron-multiplying charge-coupled device (EMCCD) offers improved quantum efficiencies (40 to 95%) over a broader range of wavelengths (400 to 900 nm) and a higher intrinsic resolution (<100 mum using photon counting) when compared to photomultiplier tubes. The electron gain achieved in the multiplication register of an EMCCD effectively reduces the readout noise to less than 1 electron/pixel, making them sensitive to single photoelectrons. Our prototype camera uses the Texas Instruments Impactrontrade EMCCD model TC253SPD-B0 (7.4 mum square pixels) which is cooled under vacuum to -50degC using a four stage Peltier and liquid heat exchanger. Shuttered lens-coupling is used to image the optical light from a 3 mm thick monolithic CsI(Tl) crystal. Precise clocking for the EMCCD is provided by a National Instruments FPGA controller (PCI-7811R) and LabVIEW FPGA module (version 8.0). A custom built electronics box contains the clock driver circuitry and 16-bit video board for digital conversion of the video signal. Our optical coupling method differs from other EMCCD SPECT systems by using lenses rather than fiber optic bundles for transfer. TC253 characterization tests measured a maximum gain just over 1000times, dark current rate of 0.14 e/p/s, read noise of 18.2 e/p, and spurious charge generation of 4 e/p. A light integration intrinsic resolution of 110 mum FWHM was measured. Light integration images of a line phantom using a single pinhole collimator were used for SPECT reconstruction. We found the relative high spurious charge generation and low quantum efficiency of the TC253 made it incapable of photon counting for low energy sources using lens coupling.

13 July 2009
Verified
Book Chapter
Open access
PDF file
ACAngelina Contero
Angelina Contero
EREdmond Richer
Edmond Richer
AGAna Gondim
Ana Gondim
Ralph MasonRalph Mason
Ralph Mason
Bioluminescence imaging (BLI) has emerged during the past 5 years as the preeminent method for rapid, cheap, facile screening of tumor growth and spread in mice. Both subcutaneous and orthotopic tumor models are readily observed with high sensitivity and reproducibility. User-friendly commercial instruments exist and, increasingly, luciferase-expressing tumor cells are available in academic institutions or commercially. There is an increasing literature on routine use of BLI for assessing chemotherapeutic efficacy, drug combinations, dosing, and timing. In addition, BLI may be applied to more sophisticated questions of molecular biology by including specific promoter sequences. This chapter will describe routine methods used to support multiple investigators in our small animal imaging resource.

14 November 2023 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ACAdam Cox
Adam Cox
CCChristopher Lee Colaw
Christopher Lee Colaw
EREdmond Richer
Edmond Richer
MGMatthew Galla
Matthew Galla
Yildirim HurmuzluYildirim Hurmuzlu
Yildirim Hurmuzlu
Inspection of tube networks is an important process in the manufacturing and maintenance of aircraft. Currently, borescopes are commonly used with limited success. To improve the inspection process, a prototype design based on a vertebra concept is introduced, analyzed, and optimized. The modular robotic inspection system (MoRIS) allows for a microsized camera to be driven noninvasively through a 3-m-long, 36-mm internal diameter tube network. MoRIS provides a complete view of the tube walls. Our system includes a localization algorithm that tracks the progress of the robot inside the tubes. This algorithm results in an experimentally validated error of 19.7 mm. Using MoRIS, operators can inspect tube networks that previously required hazardous disassembly of aircraft.