6 July 2021 in IEEE Sensors Journal
In vascular interventional surgery, experienced physicians rely on proximal force sensing to detect the collision and reduce vascular injury caused by surgical tools. However, in robot-assisted tele-interventional surgery (RATIS), providing high-precision force feedback to physician is still a main challenge. In this paper, a haptic robot-assisted catheter operating system with a novel spring-based haptic force interface was developed. With a closed loop force adjustment system, the haptic force interface can provide accuracy force feedback. Moreover, a collision protection function with a proximal-force-based collision detection algorithm was proposed to improve surgical safety. In case of no collision, transparency of the teleoperated system is realized; in case of collision, the provided haptic force will be amplified. The results demonstrated the usability of the developed haptic robot-assisted catheter operating system with collision protection function.
24 August 2021 in IEEE Sensors Journal
In vascular interventional surgery (VIS), the doctors often need to be exposed to X-ray radiation for a long time, operate surgical instruments (Ex. Guidewires and catheters) to perform the operation, which is difficult to ensure the health of surgeons and the safety of operation. In addition, the force between the blood vessel wall and the surgical instrument is complex and variable, the existence of the external disturbance forces easily affects the judgment of the doctors. In this paper, to ensure the health and reduce the fatigue of the doctors, a novel tactile sensing robot-assisted system for VIS was developed to assist the surgeons to complete the operation. Then, the forces between the blood vessel and the surgical instrument during the surgery were analyzed. Besides, a self-developed force sensor was used to confirm the collision force between the tip of the catheter and the blood vessel wall. Finally, combining the haptic force feedback of the system and the developed force sensor, a series of experiments in “Vitro” were completed, and it was indicated by the experiment results that the accuracy of the force feedback can be improved by using the analysis method proposed in this paper, the collision force between the catheter tip and the blood vessel environment can be confirmed by the self-developed force sensor. Based on the results, the developed robot-assisted system for VIS has high safety.
28 April 2022 in IEEE Transactions on Instrumentation and Measurement
The procedure of vascular interventional surgery (VIS) is very complicated. It requires doctors to wear the protecting suits and manipulate the flexible instruments (catheters and guidewires) for a long time to complete the treatment, which may fatigue the doctors and lead to misoperation. Besides, the X-ray radiation in the operating room is also bad for doctors’ health. So, to solve the above challenges, a novel robot-assisted system was developed for VIS, which realizes the separation of the doctor and the operating room; a preliminary method was used on the slave side to reduce the excessive collision force when the tip of the catheter travels through the curved blood vessel, and the active enhancing safety method of the robot-assisted system was proposed to reduce the danger caused by doctors’ misoperation (dangerous behaviors) during the surgery. Finally, to verify the proposed methods, a series of experiments in vitro were conducted, and experimental results indicated that the method of assisting the deflection of the tip of the catheter has the potential to reduce the excessive collision force, the collision force at the tip of the catheter was reduced by 0.104 N when a misoperation occurred during the operation procedure under the condition of the active enhancing safety method, and the stronger sense of the tactile presence was generated by the master manipulator when the total force of the slave side was greater than 1.0 N. Therefore, based on the above results, we believe that the proposed methods are effective.
1 December 2023 in IEEE Transactions on Instrumentation and Measurement
Robot-assisted vascular interventional surgery (RVIS) is an emerging technology for the treatment of vascular diseases. It has obvious advantages over traditional manual operation, such as increased accuracy, reduced fatigue, and reduced tremor. However, current research suggests that natural human–robot interaction in RVIS is still a challenge that needs to be addressed. In this article, we developed a novel robotic platform that realized magnetorheological (MR) fluids-based haptic feedback to improve the interventionist’s tactile presence. In addition, we proposed a force sensing method to accurately detect the real-time force of the flexible instrument and a collaborative operation method of the guidewire and the catheter to assist the flexible instruments in selecting the target blood vessel branch and reduce the operation difficulty of the interventionist. To verify the developed robotic platform and the proposed methods, we conducted the performance evaluation experiments in a blood vessel model and an endo vascular evaluator. The results indicated that the developed robotic platform and the proposed methods have great potential to improve the natural human–robot interaction in RVIS and guarantee safety.
21 October 2022 in IEEE Transactions on Instrumentation and Measurement
Vascular interventional surgery (VIS) robots generally rely on faster and more accurate signal interaction system between the master side and slave side. During actual operations, unconscious and nonlinear tremors limit the accuracy and safety for VIS robot’s operation. To solve above issues, this article proposes a novel bimodal detection-based tremor suppression system to improve the accuracy of data interaction. More precisely, a bimodal tremor detection combined self-designed force sensitive resistor (FSR) and a linear encoder sensor is employed for radial and axial tremor detection, respectively. Tremor suppression method based on active restraint and passive modification is presented in this study, which can not only reduce the regular tremor but also effectively suppress the suddenly burst tremor. Experiments and performance analysis of the proposed method are evaluated from simulations and actual experimental results. Based on these evaluations, the tremor suppression method has obvious advantages for suppressing non-linear tremors and enhancing the timeliness of signal interaction, which the average computing time for tremor is 140 ms and average maximum amplitude moves to 2.47 mm. Moreover, we also discuss the issues for time delay and the transmission loss existed in actual experiments. Besides, this article has a potential impact on eliminating non-linear errors, improving the safety performance of operations for master–slave robotic system, and solving the crossing problem for time–frequency domain.