Dhermendra K. Tiwari

Dhermendra K. Tiwari

Auto-generated profile, based on publicly available information

Dhermendra K. Tiwari

School of Biological Sciences and Biotechnology, Goa University, India

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2010 in Toxicology Mechanisms and Methods
Verified
Journal Article
Closed access
PDF file
DTDhermendra K Tiwari
Dhermendra K Tiwari
TJTakashi Jin
Takashi Jin
JBJ. Behari
J. Behari
This study aims to suggest the limits of silver nanoparticle (AgNP) uses for medicinal purpose and was performed to explore the effect of various doses of silver nanoparticle in rats. Four different doses of AgNP (4, 10, 20, and 40 mg/kg) were injected intravenously. For safety evaluation of injected AgNP, body weight, organ coefficient, whole blood count, and biochemistry panel assay for liver function enzyme (AST, ALT, ALP, and GGTP), comet assay, ROS, and histological parameter were performed; 10–12 week old animals were randomly divided into groups of six individuals each for control, and doses of 40, 20, 10, and 4 mg/kg AgNP injected. Significant changes were observed (p < 0.01) in hematological parameters (WBC count, platelets counts, haemoglobin, and RBC count) in the 40 and 20 mg/kg groups. The changes were non-significant in the other groups (4 and 10 mg/kg group). In the 40 mg/kg group, a significant increase was also found in liver function enzymes like ALT and AST (p < 0.01), ALP (p < 0.01), GGTP (p < 0.01), and bilirubin (p < 0.01). ROS in blood serum increased in the high dose group. Tail migration in single cell gel electrophoresis in the 40, 20, 10, 4 mg/kg, and control groups was 34.9, 29.5, 17.8, 5.8, and 0.0 µm, respectively, which indicated damage in the DNA strand in the high dose group. EDXRF showed a ∼ 10-times increase in silver concentration in the 40 mg/kg group and TEM image also showed particle deposition in the 40 mg/kg group. This study indicates that the AgNP in doses (< 10 mg/kg) is safe for biomedical application and has no side-effects, but its high dose (> 20 mg/kg) is toxic.

9 December 2010 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
STShin‐Ichi Tanaka
Shin‐Ichi Tanaka
JMJun Miyazaki
Jun Miyazaki
DTDhermendra K. Tiwari
Dhermendra K. Tiwari
TJTakashi Jin
Takashi Jin
YIYasushi Inouye
Yasushi Inouye

20 April 2015 in Nature Methods
Verified
Journal Article
Closed access
PDF file
DTDhermendra K Tiwari
Dhermendra K Tiwari
YAYoshiyuki Arai
Yoshiyuki Arai
MYMasahito Yamanaka
Masahito Yamanaka
TMTomoki Matsuda
Tomoki Matsuda
MAMasakazu Agetsuma
Masakazu Agetsuma
TNTakeharu Nagai
Takeharu Nagai

19 November 2009 in Sensors
Verified
Journal Article
Open access
PDF file
DTDhermendra K. Tiwari
Dhermendra K. Tiwari
STShin-Ichi Tanaka
Shin-Ichi Tanaka
YIYasushi Inouye
Yasushi Inouye
KYKeiko Yoshizawa
Keiko Yoshizawa
TWTomonobu M. Watanabe
Tomonobu M. Watanabe
TJTakashi Jin
Takashi Jin
The early detection of HER2 (human epidermal growth factor receptor 2) status in breast cancer patients is very important for the effective implementation of anti-HER2 antibody therapy. Recently, HER2 detections using antibody conjugated quantum dots (QDs) have attracted much attention. QDs are a new class of fluorescent materials that have superior properties such as high brightness, high resistance to photo-bleaching, and multi-colored emission by a single-light source excitation. In this study, we synthesized three types of anti-HER2 antibody conjugated QDs (HER2Ab-QDs) using different coupling agents (EDC/sulfo-NHS, iminothiolane/sulfo-SMCC, and sulfo-SMCC). As water-soluble QDs for the conjugation of antibody, we used glutathione coated CdSe/CdZnS QDs (GSH-QDs) with fluorescence quantum yields of 0.23~0.39 in aqueous solution. Dispersibility, hydrodynamic size, and apparent molecular weights of the GSH-QDs and HER2Ab-QDs were characterized by using dynamic light scattering, fluorescence correlation spectroscopy, atomic force microscope, and size-exclusion HPLC. Fluorescence imaging of HER2 overexpressing cells (KPL-4 human breast cancer cell line) was performed by using HER2Ab-QDs as fluorescent probes. We found that the HER2Ab-QD prepared by using SMCC coupling with partially reduced antibody is a most effective probe for the detection of HER2 expression in KPL-4 cells. We have also studied the size dependency of HER2Ab-QDs (with green, orange, and red emission) on the fluorescence image of KPL-4 cells.

10 September 2010 in Molecular BioSystems
Verified
Journal Article
Closed access
PDF file
TJTakashi Jin
Takashi Jin
DTDhermendra K. Tiwari
Dhermendra K. Tiwari
STShin-Ichi Tanaka
Shin-Ichi Tanaka
YIYasushi Inouye
Yasushi Inouye
KYKeiko Yoshizawa
Keiko Yoshizawa
TWTomonobu M. Watanabe
Tomonobu M. Watanabe
To use quantum dots (QDs) as fluorescent probes for receptor imaging, QD surface should be modified with biomolecules such as antibodies, peptides, carbohydrates, and small-molecule ligands for receptors. Among these QDs, antibody conjugated QDs are the most promising fluorescent probes. There are many kinds of coupling reactions that can be used for preparing antibody conjugated QDs. Most of the antibody coupling reactions, however, are non-selective and time-consuming. In this paper, we report a facile method for preparing antibody conjugated QDs for surface receptor imaging. We used ProteinA as an adaptor protein for binding of antibody to QDs. By using ProteinA conjugated QDs, various types of antibodies are easily attached to the surface of the QDs via non-covalent binding between the Fc (fragment crystallization) region of antibody and ProteinA. To show the utility of ProteinA conjugated QDs, HER2 (anti-human epidermal growth factor receptor 2) in KPL-4 human breast cancer cells were stained by using anti-HER2 antibody conjugated ProteinA–QDs. In addition, multiplexed imaging of HER2 and CXCR4 (chemokine receptor) in the KPL-4 cells was performed. The result showed that CXCR4 receptors coexist with HER2 receptors in the membrane surface of KPL-4 cells. ProteinA mediated antibody conjugation to QDs is very useful to prepare fluorescent probes for multiplexed imaging of surface receptors in living cells.

16 December 2022 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
SDSuman Das
Suman Das
BSBijay Saha
Bijay Saha
MTManisha Tiwari
Manisha Tiwari
DTDhermendra K. Tiwari
Dhermendra K. Tiwari
Basic principle of sensing technique of various carbon nanomaterial-based biosensors.