Stephen J. Wastling

Stephen J. Wastling

Auto-generated profile, based on publicly available information

Stephen J. Wastling

University College London Hospitals NHS Foundation Trust , London , UK

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Radiology
Verified
Journal Article
Closed access
JMJohn Maynard
John Maynard
SOSachi Okuchi
Sachi Okuchi
SWStephen Wastling
Stephen Wastling
ABAyisha Al Busaidi
Ayisha Al Busaidi
OAOfran Almossawi
Ofran Almossawi
Stefanie Catherine ThustStefanie Catherine Thust
Stefanie Catherine Thust
An algorithm on the basis of standard MRI sequences and age predicted isocitrate dehydrogenase status in lower-grade gliomas without advanced computational methods. Background A readily implemented MRI biomarker for glioma genotyping is currently lacking. Purpose To evaluate clinically available MRI parameters for predicting isocitrate dehydrogenase (IDH) stat...

29 January 2024 in Neuro-Oncology
Verified
Journal Article
Open access
PDF file
ACAlysha Chelliah
Alysha Chelliah
DWDavid A Wood
David A Wood
LCLiane S Canas
Liane S Canas
HSHaris Shuaib
Haris Shuaib
SCStuart Currie
Stuart Currie
TBThomas C Booth
Thomas C Booth
The aim was to predict survival of glioblastoma at 8 months after radiotherapy (a period allowing for completing a typical course of adjuvant temozolomide), by applying deep learning to the first brain MRI after radiotherapy completion. Retrospective and prospective data were collected from 206 consecutive glioblastoma, isocitrate dehydrogenase -wildtype patients diagnosed between March 2014 and February 2022 across 11 UK centers. Models were trained on 158 retrospective patients from 3 centers. Holdout test sets were retrospective (n = 19; internal validation), and prospective (n = 29; external validation from 8 distinct centers). Neural network branches for T2-weighted and contrast-enhanced T1-weighted inputs were concatenated to predict survival. A nonimaging branch (demographics/MGMT/treatment data) was also combined with the imaging model. We investigated the influence of individual MR sequences; nonimaging features; and weighted dense blocks pretrained for abnormality detection. The imaging model outperformed the nonimaging model in all test sets (area under the receiver-operating characteristic curve, AUC P = .038) and performed similarly to a combined imaging/nonimaging model (P > .05). Imaging, nonimaging, and combined models applied to amalgamated test sets gave AUCs of 0.93, 0.79, and 0.91. Initializing the imaging model with pretrained weights from 10 000s of brain MRIs improved performance considerably (amalgamated test sets without pretraining 0.64; P = .003). A deep learning model using MRI images after radiotherapy reliably and accurately determined survival of glioblastoma. The model serves as a prognostic biomarker identifying patients who will not survive beyond a typical course of adjuvant temozolomide, thereby stratifying patients into those who might require early second-line or clinical trial treatment.

7 January 2021 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
Stefanie Catherine ThustStefanie Catherine Thust
Stefanie Catherine Thust
JMJ.A. Maynard
J.A. Maynard
MBM. Benenati
M. Benenati
SWS.J. Wastling
S.J. Wastling
LMLaura Mancini
Laura Mancini
HJH.R. Jäger
H.R. Jäger
537 Objectives Lung density changes during respiration which affects PET/CT quantification in the lung. We investigate the relation between density changes measured in CT, FDG concentration changes measured in PET and local volume changes obtained from the registration deformation field. Methods CINE CT and FDG PET data were acquired from patients suffering from lung cancer with solitary pulmonary nodules. These data were respiratory gated into 6 gates using the amplitude of the respiratory signal from an external device (RPM). Gated PET data were reconstructed with matched gated CT for the attenuation correction. After segmenting the lungs on the gated CT images, we performed an affine plus a non-rigid registration (NiftyReg with the Normalized Mutual Information objective function) of gated CT to a reference gate, which was chosen to correspond to an inhalation breathing state (i.e largest lung volume). From each registration, the local volume change (i.e Jacobian determinant) was measured from estimated deformation fields. ROIs were drawn on the lung away from edges, obvious artefacts and blood vessels. Regions where density changed less than 5% were excluded. Results The registration was visually judged to be of very good quality. The density and the PET tracer concentration were not conserved after registration. The average difference in density (PET concentration) between the registered image and the reference is 10% (15%), but this reduced to 5% (8%) after correcting for local volume change. The density and PET concentration are linearly related with a positive slope and a non-zero intercept (r2 between 0.6 and 0.9). Conclusions We have shown that using the Jacobian underestimates the correction needed to preserve both density and PET concentration. The non-zero intercept in the density-activity relationship suggests a lack of local conservation of PET activity. In the future, we will investigate if this could be clarified by taking the PET tracer in blood into account. Research Support This work is supported by funding from GSK, Fibrosis DPU, GlaxoSmithKline R&D and EPSRC. This project is supported by researchers at the National Institute for Health Research, University College London Hospitals Biomedical Research Centre.

1 December 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
OKOliver C. Kiersnowski
Oliver C. Kiersnowski
AKAnita Karsa
Anita Karsa
SWStephen J. Wastling
Stephen J. Wastling
JTJohn S. Thornton
John S. Thornton
KSKarin Shmueli
Karin Shmueli
Purpose: Quantitative susceptibility mapping (QSM) is increasingly used for clinical research where oblique image acquisition is commonplace but its effects on QSM accuracy are not well understood. Theory and Methods: The QSM processing pipeline involves defining the unit magnetic dipole kernel, which requires knowledge of the direction of the main magnetic field with respect to the acquired image volume axes. The direction of is dependent upon the axis and angle of rotation in oblique acquisition. Using both a numerical brain phantom and in-vivo acquisitions in five healthy volunteers, we analysed the effects of oblique acquisition on magnetic susceptibility maps. We compared three tilt correction schemes at each step in the QSM pipeline: phase unwrapping, background field removal and susceptibility calculation, using the root-mean-squared error and QSM-tuned structural similarity index (XSIM). Results: Rotation of wrapped phase images gave severe artefacts. Background field removal with PDF gave the most accurate susceptibilities when the field map was first rotated into alignment with . LBV and V-SHARP background field removal methods gave accurate results without tilt correction. For susceptibility calculation, thresholded k -space division, iterative Tikhonov regularisation and weighted linear total variation regularisation all performed most accurately when local field maps were rotated into alignment with before susceptibility calculation. Conclusion: For accurate QSM, oblique acquisition must be taken into account. Rotation of images into alignment with should be carried out after phase unwrapping and before background field removal. We provide open-source tilt-correction code to incorporate easily into existing pipelines: https://github.com/o-snow/QSM_TiltCorrection.git .

10 June 2025 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
JWJiaming Wu
Jiaming Wu
Stefanie Catherine ThustStefanie Catherine Thust
Stefanie Catherine Thust
SWStephen J. Wastling
Stephen J. Wastling
GAGehad Abdalla
Gehad Abdalla
MBMassimo Benenati
Massimo Benenati
FBFrederik Barkhof
Frederik Barkhof
BACKGROUND AND PURPOSE: Glioma molecular characterization is essential for risk stratification and treatment planning. Noninvasive imaging biomarkers such as apparent diffusion coefficient (ADC) values have shown potential for predicting glioma genotypes. However, manual segmentation of gliomas is time-consuming and operator-dependent. To address this limitation, we aimed to establish a single-sequence-derived automatic ADC extraction pipeline using T2-weighted imaging to support glioma isocitrate dehydrogenase (IDH) genotyping. MATERIALS AND METHODS: Glioma volumes from a hospital data set (University College London Hospitals; n=247) were manually segmented on T2-weighted MRI scans using ITK-Snap Toolbox and co-registered to ADC maps sequences using the FMRIB Linear Image Registration Tool in FSL, followed by ADC histogram extraction (Python). Separately, a nnUNet deep learning algorithm was trained to segment glioma volumes using T2w only from BraTS 2021 data (n=500, 80% training, 5% validation and 15% test split). nnUnet was then applied to the University College London Hospitals (UCLH) data for segmentation and ADC read-outs. Univariable logistic regression was used to test the performance manual and nnUNet derived ADC metrics for IDH status prediction. Statistical equivalence was tested (paired two-sided t-test). RESULTS: nnUnet segmentation achieved a median Dice of 0.85 on BraTS data, and 0.83 on UCLH data. For the best performing metric (rADCmean) the area under the receiver operating characteristic curve (AUC) for differentiating IDH-mutant from IDHwildtype gliomas was 0.82 (95% CI: 0.78-0.88), compared to the manual segmentation AUC 0.84 (95% CI: 0.77-0.89). For all ADC metrics, manually and nnUNet extracted ADC were statistically equivalent (p<0.01). nnUNet identified one area of glioma infiltration missed by human observers. In 0.8% gliomas, nnUnet missed glioma components. In 6% of cases, over-segmentation of brain remote from the tumor occurred (e.g. temporal poles). CONCLUSIONS: The T2w trained nnUnet algorithm achieved ADC readouts for IDH genotyping with a performance statistically equivalent to human observers. This approach could support rapid ADC based identification of glioblastoma at an early disease stage, even with limited input data. ABBREVIATIONS: AUC = Area under the receiver operating characteristic curve, BraTS = The brain tumor segmentation challenge held by MICCAI, Dice = Dice Similarity Coefficient, IDH = Isocitrate dehydrogenase, mGBM = Molecular glioblastoma, ADCmin = Fifth ADC histogram percentile, ADCmean = Mean ADC value, ADCNAWM = ADC in the contralateral centrum semiovale normal white matter, rADCmin = Normalized ADCmin, VOI rADCmean = Normalized ADCmean.