Luiz Carlos de Lima Dias-Junior

Luiz Carlos de Lima Dias-Junior

Auto-generated profile, based on publicly available information

Luiz Carlos de Lima Dias-Junior

Division of Endodontics, Department of Diagnosis and Oral Health, School of Dentistry University of Louisville Louisville Kentucky USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Brazilian Dental Journal
Verified
Journal Article
Open access
WGWesley Fernandes Gonçalves
Wesley Fernandes Gonçalves
LGLucas da Fonseca Roberti Garcia
Lucas da Fonseca Roberti Garcia
DVDaniela Peressoni Vieira-Schuldt
Daniela Peressoni Vieira-Schuldt
EBEduardo Antunes Bortoluzzi
Eduardo Antunes Bortoluzzi
LDLuiz Carlos de Lima Dias-Júnior
Luiz Carlos de Lima Dias-Júnior
CTCLEONICE DA SILVEIRA TEIXEIRA
CLEONICE DA SILVEIRA TEIXEIRA
This article reported two clinical cases in which the guided endodontics was used to perform the access to the root canals. The first case presents a 40-year-old female with a history of pain related to the left maxillary canine. After radiographic examination, the presence of severe calcification up to the apical third of the root canal, associated with a periapical radiolucency, was noted. In the second case, an 85-year-old male was referred to our service with pain upon palpation, at the right mandibular first molar. The radiographic images revealed the presence of endodontic treatment and a fiberglass post in the distal root canal, which was associated with extrusion of the filling material and a periapical lesion. The 3D-guides were planned based on cone beam computed tomography and intraoral digital scanning, which were aligned using a specific software. Therefore, implant drills could be guided up to the root canal length required for each case. In the first case, a surgical root canal was created and the patient was free of signs and symptoms after the treatment was completed. In the second case, it was observed that the fiber post was worn by the drill, allowing free access to the filling material. It was possible to perform the endodontic reintervention in a more predictable way and in less time. In both cases, the use of the guided endodontics allowed the preservation of a large part of the dental structure. The procedures were performed faster, without the occurrence of fractures and perforations.

10 April 2024 in Australian Endodontic Journal
Verified
Journal Article
Closed access
BFBruna Venzke Fischer
Bruna Venzke Fischer
LDLuiz Carlos de Lima Dias‐Junior
Luiz Carlos de Lima Dias‐Junior
MMMariana Comparotto Minamisako
Mariana Comparotto Minamisako
CACristiane Maria Almeida
Cristiane Maria Almeida
LSLuciano Roberto da Silva
Luciano Roberto da Silva
LGLucas da Fonseca Roberti Garcia
Lucas da Fonseca Roberti Garcia

19 November 2024 in International Journal of Adhesion and Adhesives
Verified
Journal Article
Closed access
MMMarcos Testa Magoga
Marcos Testa Magoga
RSRafaela Lourdes de Sousa
Rafaela Lourdes de Sousa
LDLuiz Carlos Lima Dias-Junior
Luiz Carlos Lima Dias-Junior
RSRayssa Sabino-Silva
Rayssa Sabino-Silva
MMMariana Comparotto Minamisako
Mariana Comparotto Minamisako
LGLucas da Fonseca Roberti Garcia
Lucas da Fonseca Roberti Garcia

1 January 2025 in International Journal of Dentistry
Verified
Journal Article
Open access
MDMaria Eduarda Paz Dotto
Maria Eduarda Paz Dotto
JSJulia Menezes Savaris
Julia Menezes Savaris
LDLuiz Carlos de Lima Dias-Junior
Luiz Carlos de Lima Dias-Junior
TSTamer Ferreira Schmidt
Tamer Ferreira Schmidt
LGLucas da Fonseca Roberti Garcia
Lucas da Fonseca Roberti Garcia
EBEduardo Antunes Bortoluzzi
Eduardo Antunes Bortoluzzi
Introduction: There is a concern regarding the heating transfer to the periodontal tissues after irrigating solution activation. Therefore, this study analyzed the real‐time changes in internal and external root temperatures using different systems for activating the irrigant. Methods: Two single‐rooted mandibular premolars were chemomechanically prepared. Three orifices were drilled on the root surface at 3, 6, and 9 mm from the apical foramen with a spherical diamond bur. In one tooth, drilling was restricted to the cementum. In another tooth, drilling was performed close to canal dentin. Thermocouple sensors were coupled to the orifices and fixed with resin for temperature measurement. Irrigation was performed with 2.5% NaOCl at 25°C or 45°C. The irrigant was activated for 20‐, 30‐ and 60 s using 3 different systems: passive ultrasonic irrigation (PUI), Ultra X (UX), and endoactivator (EA). For each initial irrigant temperature, time, and activation system, the tests were repeated 8 times, resulting in a total of 96 evaluations for the external and internal root temperatures ( n = 48 for each). Results: Data was statistically analyzed with a multilevel linear regression model and intraclass correlation coefficients (ICCs) were calculated. Then, four‐way ANOVA with Bonferroni’s post hoc tests performed intergroup and intragroup comparisons. EA promoted lower temperature increase than PUI and UX ( p < 0.05). PUI and UX induced similar internal and external temperature changes when irrigated with NaOCl at 25°C.. Conclusion: The initial temperatures (25°C or 45°C) and the activation systems of the irrigant had influence on the internal and external radicular temperatures. The activation period had little influence on root temperature changes, which may be deemed clinically safe.

1 January 2025 in International Journal of Dentistry
Verified
Journal Article
Open access
LDLuiz Carlos de Lima Dias-Junior
Luiz Carlos de Lima Dias-Junior
DSDiego Leonardo de Souza
Diego Leonardo de Souza
ABAdriana Pinto Bezerra
Adriana Pinto Bezerra
MCMarcio Correa
Marcio Correa
CTCLEONICE DA SILVEIRA TEIXEIRA
CLEONICE DA SILVEIRA TEIXEIRA
LGLucas da Fonseca Roberti Garcia
Lucas da Fonseca Roberti Garcia
This systematic review investigated the different factors associated with the diagnostic accuracy of vertical root fractures (VRFs) with cone‐beam computed tomography (CBCT) scans, assessed by in vitro studies. Studies were screened from PubMed, Embase, Scopus, Web of Science, and Lilacs, up to May 2025. The included studies assessed the diagnostic accuracy of CBCT scans for laboratory‐induced VRFs. The quality assessment of the included studies was performed using the QUADAS‐2 tool. Meta‐analyses were performed using the bivariate model with random effects to produce summary sensitivity (SSe) and specificity (SSp) with a 95% confidence interval (CI). The influence of confounding factors on the accuracy of CBCT images was investigated by meta‐regression models. Covariates were added to the bivariate model to assess the impact on sensitivity, specificity, or both. The quality of evidence of each meta‐analysis was assessed using the GRADE approach. One hundred studies were included. Twenty‐four studies presented a low risk of bias, 22 moderate risk, and 54 high risk. CBCT scans presented a higher sensitivity for the diagnosis of complete VRFs compared to incomplete fractures. The presence of metal posts impaired both sensitivity and specificity. Smaller voxel sizes favored the detection of VRFs in teeth with metal posts. In laboratory settings, the diagnosis of VRFs by CBCT images is mainly affected by the fracture pattern, presence of intracanal materials, and voxel size.

9 October 2023 in Microscopy Research and Technique
Verified
Journal Article
Closed access
EMEmanuelle Catherine Maiola
Emanuelle Catherine Maiola
LBLetícia Mendes Boppré
Letícia Mendes Boppré
JSJulia Menezes Savaris
Julia Menezes Savaris
LJLuiz Carlos de Lima Dias Junior
Luiz Carlos de Lima Dias Junior
LGLucas da Fonseca Roberti Garcia
Lucas da Fonseca Roberti Garcia
EBEduardo Antunes Bortoluzzi
Eduardo Antunes Bortoluzzi