Patrícia de Almeida Rodrigues

Patrícia de Almeida Rodrigues

Auto-generated profile, based on publicly available information

Patrícia de Almeida Rodrigues

Graduate Program in Dentistry, Institute of Health Sciences, Federal University of Pará, Belém, Brazil

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2010 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
MJMario Honorato Silva E Souza Junior
Mario Honorato Silva E Souza Junior
KCKarina Gama Kato Carneiro
Karina Gama Kato Carneiro
MLMarcelo Figueiredo Lobato
Marcelo Figueiredo Lobato
PSPatrícia De Almeida Rodrigues Silva E Souza
Patrícia De Almeida Rodrigues Silva E Souza
MGMário Fernando De Góes
Mário Fernando De Góes
This literature review article addresses the types and the main components of different etch-and-rinse and self-etch adhesive systems available in the market, and relates them to their function, possible chemical interactions and influence of handling characteristics. Scanning electron microscopy (SEM) images are presented to characterize the interface between adhesives and dentin. Adhesive systems have been recently classified according to their adhesion approaches in etch-and-rinse, self-etch and glass ionomer. The etch-andrinse systems require a specific acid-etch procedure and may be performed in two or three steps. Self-etch systems employ acidic monomers that demineralize and impregnate dental substrates almost at the same time. These systems are separated in one or two steps. Some advantages and deficiencies were noted for etch-and-rinse and self-etch approaches, mainly for the simplified ones due to some chemical associations and interactions. The SeM micrographs illustrate different relationships between adhesive systems and dental structures, particularly dentin. The knowledge of composition, characteristics and mechanisms of adhesion of each adhesive system is of fundamental importance to permit the adoption of ideal bonding strategies under clinical conditions.

1 September 2013 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
TTTalita Tartari
Talita Tartari
AJAnivaldo Pereira Duarte Junior
Anivaldo Pereira Duarte Junior
JJJose Otavio Carrera Silva Junior
Jose Otavio Carrera Silva Junior
EKEliza Burlamaqui Klautau
Eliza Burlamaqui Klautau
MJMario Honorato Silva e Souza Junior
Mario Honorato Silva e Souza Junior
PJPatricia de Almeida Rodrigues Silva e Souza Junior
Patricia de Almeida Rodrigues Silva e Souza Junior
An increase in dentin roughness, associated with surface composition, contributes to bacterial adherence in recontaminations. Surface roughness is also important for micromechanical interlocking of dental materials to dentin, and understanding the characteristics of the surface is essential to obtain the adhesion of root canal sealers that have different physico-chemical characteristics.

1 January 2013 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
TTTalita Tartari
Talita Tartari
PSPatrícia de Almeida Rodrigues Silva e Souza
Patrícia de Almeida Rodrigues Silva e Souza
BABruno Vila Nova de Almeida
Bruno Vila Nova de Almeida
JJJosé Otávio Silva Júnior
José Otávio Silva Júnior
OPOscar Facíola Pessoa
Oscar Facíola Pessoa
MJMario Honorato Silva e Souza Junior
Mario Honorato Silva e Souza Junior
This study investigated the effect of sodium hypochlorite (NaOCl), ethylenediaminetetraacetic (EDTA), etidronic (HEBP), and citric acid (CA) associated in different irrigation regimens on root dentin microhardness. Forty-five root halves of single-rooted teeth were sectioned into thirds that were embedded in acrylic resin, polished, randomly assigned into 3 groups, and treated as follows: G1: saline solution; G2: 5% NaOCl + 18% HEBP, mixed in equal parts; and G3: 2.5% NaOCl. After measurements, the G3 samples were distributed into subgroups G4, G5, and G6, which were submitted to 17% EDTA, 10% CA and 9% HEBP, respectively. Following the new measurements, these groups received a final flush with 2.5% NaOCl, producing G7, G8, and G9. Microhardness was measured with Knoop indenter under a 25 g load for 15 seconds, before and after treatments. The data were statistically analyzed using paired Student’st-test (α<0.05) to compare values before and after treatments and analysis of variance (ANOVA) (α<0.05) to detect any differences among thirds. Except G1, all tested irrigation regimens significantly decreased the microhardness. There were no differences between root thirds before treatments, and all root thirds exhibited equal responses to same treatment. Except saline, all tested irrigation regimens reduced the root dentin microhardness.

9 April 2018
Verified
Journal Article
Open access
BNBrenna Magdalena Lima Nogueira
Brenna Magdalena Lima Nogueira
TPThais Isabele da Costa Pereira
Thais Isabele da Costa Pereira
Victor Feliz PedrinhaVictor Feliz Pedrinha
Victor Feliz Pedrinha
PRPatrícia de Almeida Rodrigues
Patrícia de Almeida Rodrigues
The aim of this study was to evaluate the effect of different irrigating solutions and irrigation protocols on the chemical and physical structure of root dentin. Thirty extracted single-rooted human teeth were selected and then distributed into the following treatment groups (n=10): G1, saline solution (0.9% NaCl); G2, 2.5% NaOCl + 17% EDTA + 2.5% NaOCl; G3, 2.5% NaOCl + 9% Etidronate (HEBP) + 2.5% NaOCl; G4, mixture of 5% NaOCl + 18% HEBP; G5, 2.5% NaOCl + 17% EDTA + 0.9% NaCl, and G6, 2.5% NaOCl + 9% HEBP + 0.9% NaCl. The ultrastructure of dentin was characterized through scanning electron microscopy (SEM) and energy dispersive x-ray spectrometry (EDS) determined the chemical composition in terms of the calcium (Ca), phosphorus (P), magnesium (Mg) and potassium (K) content and the Ca/P ratio; and the crystalline phase was analyzed by x-ray diffraction (XRD). A descriptive analysis was performed on the ultrastructure and the crystallography data of dentin. Data analysis included a chemical composition analysis of variance (one-way ANOVA) and a subsequent multiple comparison test (Tukey’s test). Except for the control group, all groups showed morphological changes upon visualization with SEM. For EDS, G2 and G5 showed significant mineral loss and changes in the Ca/P ratio (P<0.05); the highest values of Ca and P were observed in G3, G4 and G6. All the irrigating solutions and irrigation protocols tested promoted changes in the morphology and physical and chemical composition of the dentin. However, no significant differences were observed crystallographically.

28 February 2018 in The Open Dentistry Journal
Verified
Journal Article
Open access
PDF file
Victor Feliz PedrinhaVictor Feliz Pedrinha
Victor Feliz Pedrinha
JBJuliana Melo da Silva Brandão
Juliana Melo da Silva Brandão
OPOscar Faciola Pessoa
Oscar Faciola Pessoa
PRPatrícia de Almeida Rodrigues
Patrícia de Almeida Rodrigues
Advances in endodontics have enabled the evolution of file manufacturing processes, improving performance beyond that of conventional files. In the present study, systems manufactured using state of the art methods and possessing special properties related to NiTi alloys (i.e., CM-Wire, M-Wire and R-Phase) were selected. The aim of this review was to provide a detailed analysis of the literature about the relationship between recently introduced NiTi files with different movement kinematics and shaping ability, apical extrusion of debris and dentin defects in root canal preparations. From March 2016 to January 2017, electronic searches were conducted in the PubMed and SCOPUS databases for articles published since January 2010. In vitro studies performed on extracted human teeth and published in English were considered for this review. Based on the inclusion criteria, 71 papers were selected for the analysis of full-text copies. Specific analysis was performed on 45 articles describing the effects of reciprocating, continuous and adaptive movements on the WaveOne Gold, Reciproc, HyFlex CM and Twisted File Adaptive systems. A wide range of testing conditions and methodologies have been used to compare the systems. Due the controversies among the results, the characteristics of the files used, such as their design and alloys, appear to be inconsistent to determine the best approach.

16 July 2025 in Odontology
Verified
Journal Article
Closed access
PDF file
TGThamires Campos Gomes
Thamires Campos Gomes
PRPatrícia de Almeida Rodrigues
Patrícia de Almeida Rodrigues
JMJosé Lucas Gomes Moura
José Lucas Gomes Moura
DBDaiane Claydes Baia-da-Silva
Daiane Claydes Baia-da-Silva
LCLuciano Tavares Angelo Cintra
Luciano Tavares Angelo Cintra
Rafael Rodrigues LimaRafael Rodrigues Lima
Rafael Rodrigues Lima