Rahab Ghoveizi

Rahab Ghoveizi

Auto-generated profile, based on publicly available information

Rahab Ghoveizi

Department of Prosthodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2021 in Journal of lasers in medical sciences
Verified
Journal Article
Open access
PDF file
RGRahab Ghoveizi
Rahab Ghoveizi
RPRozbeh Parsirad
Rozbeh Parsirad
STSara Tavakolizadeh
Sara Tavakolizadeh
EBElaheh Beyabanaki
Elaheh Beyabanaki
Introduction: This study investigated the effect of various laser powers on the shear bond strength (SBS) of resin cement to the zirconia surface. Methods: Seventy-five zirconia disks were prepared and assigned to five groups including no surface treatment (control group), sandblasting with 50 µ Al2 O3 particles (second group), and Nd:YAG laser treatments with 2 W, 2.5 W and 3 W powers respectively (third, fourth and fifth groups). Afterwards, composite resin cylinders were cemented on zirconia disks using dual-curing resin cement. Before thermocycling (2000 cycles, 5-55°C), all samples were placed in distilled water at 37°C for 24 hours. Using a universal testing machine at the crosshead speed of 0.5 mm/min, the SBS was examined. Also, using a stereomicroscope, the failure type was determined. Data analyses were performed using Welch and Games-Howell tests (P< 0.05). Results: The mean bond strength difference between the control group and the other groups was significant. The respective bond strength from the highest to the lowest was observed in the sandblast group, the laser group with 2.5 W power, the laser group with 3 W power, the laser group with 2 W power, and finally the control group. However, no significant difference was observed between different laser groups (P< 0.05). Also, there was no significant difference between the sandblast and laser groups with 2.5 W and 3 W power (P< 0.05). Most of the failures in the sandblasting and laser groups with powers of 2.5 W and 3 W were mixed, but in the control and 2 W laser groups, most of the failures were of adhesive nature. Conclusion: The highest bond strength was achieved by sandblasting with Al2 O3 particles and then using an Nd: YAG laser with a power of 2.5 W.

22 May 2023 in Journal of Prosthodontics
Verified
Journal Article
Closed access
RGRahab Ghoveizi
Rahab Ghoveizi
MBMaryam Baghaei
Maryam Baghaei
STSara Tavakolizadeh
Sara Tavakolizadeh
FTFarhad Tabatabaian
Farhad Tabatabaian

19 January 2022 in Lasers in Dental Science
Verified
Journal Article
Closed access
PDF file
RGRahab Ghoveizi
Rahab Ghoveizi
MMMahsa Maleki
Mahsa Maleki
MMMaziar Mir
Maziar Mir
EBElaheh Beyabanaki
Elaheh Beyabanaki
STSara Tavakolizadeh
Sara Tavakolizadeh

16 November 2025 in Journal of lasers in medical sciences
Verified
Journal Article
Open access
PDF file
RGRahab Ghoveizi
Rahab Ghoveizi
LHLeili Habibi
Leili Habibi
EBElaheh Beyabanaki
Elaheh Beyabanaki
STSara Tavakolizadeh
Sara Tavakolizadeh
HAHossein Akbari
Hossein Akbari
Introduction: Temporomandibular disorder (TMD) is common, and occlusal splints (OSs) and low-power laser (LPL) therapy are effective conservative treatments. This study aims to compare the effectiveness of conventionally and digitally fabricated OS, with and without LPL, in treating TMD patients. Methods: Forty patients diagnosed with TMDs were randomly assigned to four treatment groups. The first group received LPL therapy in conjunction with digitally fabricated OS. The second group was treated with LPL therapy and conventionally fabricated OS. The third group received digitally made OS without LPL, and the fourth group was provided with conventionally fabricated OS without LPL. Patients’ pain levels were evaluated using a Visual Analog Scale (VAS) before treatment (pre-treatment) and at 1 week, 1 month, and 3 months post-treatment. The Association of Dental Research (IADR) scale was used to measure mouth opening and mandibular movements. Additionally, the physical characteristics of the OS were assessed over the 3-month period, including their resistance to failure, color change, and the level of patient satisfaction with the treatments. Results: There were no statistically significant differences in color change or failure rates between conventionally and digitally fabricated occlusal splints after three months (P>0.05). Likewise, patient satisfaction levels did not differ significantly between the two splint types (P>0.05). However, the conventionally fabricated splints required significantly more adjustment points and a longer delivery time (P<0.05). All four treatment groups experienced a significant reduction in pain intensity following the interventions (P<0.05). Additionally, the group receiving low-power laser therapy with digitally fabricated splints demonstrated greater improvements in all three movement parameters (P<0.05). Conclusion: The use of a combined treatment approach, involving a digitally-fabricated OS and LPL therapy could yield greater benefits for patients with TMDs in terms of pain reduction and functional improvements.

29 August 2023 in Lasers in Dental Science
Verified
Journal Article
Closed access
PDF file
STSara Tavakolizadeh
Sara Tavakolizadeh
HAHossein Akbari
Hossein Akbari
RGRahab Ghoveizi
Rahab Ghoveizi
JTJan Tunér
Jan Tunér
MMMaziar Mir
Maziar Mir
LHLeili Habibi
Leili Habibi

30 May 2026 in Journal of lasers in medical sciences
Verified
Journal Article
Open access
PDF file
RGRahab Ghoveizi
Rahab Ghoveizi
EBElaheh Beyabanaki
Elaheh Beyabanaki
STSara Tavakolizadeh
Sara Tavakolizadeh
ASAynaz Samadnezhad
Aynaz Samadnezhad
PMPejman Moradi
Pejman Moradi
Introduction: The goal of this investigation was to examine how various surface preparation techniques affect the Shear Bond Strength (SBS) of resin cement to zirconia restorations. Methods: 120 samples of zirconia ceramic disks in eight categories (10 x 3 mm) were randomly selected: 1. Control group (no surface treatments), 2. AL₂O₃ particle sandblasting, 3. 2.5 W Nd/YAG laser, 4. 3 W Nd/YAG laser, 5. Sandblasting plus 2.5 W Nd/YAG laser, 6. Sandblasting plus 3 W Nd/YAG laser, 7. 40% Hydrofluoric acid (HF), and 8. Sandblasting plus 40% HF. The analysis of one sample from each group was done using scanning. PANAVIA F2 dual-cure resin cement was then used to attach the samples to the composite resin. After thermocycling, the present researchers conducted the shear bond strength test utilizing the universal testing machine. The data were statistically evaluated using the Welch and Games-Howell tests, with a significance threshold of 0.05. Results: A statistically significant difference (P0.05). Sandblasting with HF acid etching had the greatest SBS, measuring 13.04 MPa. Out of all the groups, the SBS value was lowest for the control group (3.85 MPa). In terms of fracture type, the control group experienced more adhesive fractures. In the sandblasting and 3 W laser groups, the mixed and adhesive fractures were equal, and the mixed fracture was the most common type in the other groups. Conclusion: The greatest SBS was obtained by sandblasting combined with etching. Nevertheless, this disparity was not statistically significant. In all groups but the control group, the SBS was not statistically significant.