Jeffrey H. Miller

Jeffrey H. Miller

Auto-generated profile, based on publicly available information

Jeffrey H. Miller

University of California–Los Angeles, Los Angeles, CA, USA

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2015 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
ZLZ. Li
Z. Li
HHHouchun Harry Hu
Houchun Harry Hu
JMJ.H. Miller
J.H. Miller
JKJ.P. Karis
J.P. Karis
PCP. Cornejo
P. Cornejo
JPJ.G. Pipe
J.G. Pipe
BACKGROUND AND PURPOSE: A challenge with the T1-weighted postcontrast Cartesian spin-echo and turbo spin-echo brain MR imaging is the presence of flow artifacts. Our aim was to develop a rapid 2D spiral spin-echo sequence for T1-weighted MR imaging with minimal flow artifacts and to compare it with a conventional Cartesian 2D turbo spin-echo sequence. MATERIALS AND METHODS: T1-weighted brain imaging was performed in 24 pediatric patients. After the administration of intravenous gadolinium contrast agent, a reference Cartesian TSE sequence with a scanning time of 2 minutes 30 seconds was performed, followed by the proposed spiral spin-echo sequence with a scanning time of 1 minutes 18 seconds, with similar spatial resolution and volumetric coverage. The results were reviewed independently and blindly by 3 neuroradiologists. Scores from a 3-point scale were assigned in 3 categories: flow artifact reduction, subjective preference, and lesion conspicuity, if any. The Wilcoxon signed rank test was performed to evaluate the reviewer scores. The t test was used to evaluate the SNR. The Fleiss κ coefficient was calculated to examine interreader agreement. RESULTS: In 23 cases, spiral spin-echo was scored over Cartesian TSE in flow artifact reduction (P < .001). In 21 cases, spiral spin-echo was rated superior in subjective preference (P < .001). Ten patients were identified with lesions, and no statistically significant difference in lesion conspicuity was observed between the 2 sequences. There was no statistically significant difference in SNR between the 2 techniques. The Fleiss κ coefficient was 0.79 (95% confidence interval, 0.65–0.93). CONCLUSIONS: The proposed spiral spin-echo pulse sequence provides postcontrast images with minimal flow artifacts at a faster scanning time than its Cartesian TSE counterpart.

6 February 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
MOM.B. Ooi
M.B. Ooi
ZLZ. Li
Z. Li
RRR.K. Robison
R.K. Robison
DWD. Wang
D. Wang
AAA.G. Anderson
A.G. Anderson
JPJ.G. Pipe
J.G. Pipe
BACKGROUND AND PURPOSE: Spiral MR imaging has several advantages compared with Cartesian MR imaging that can be leveraged for added clinical value. A multicenter multireader study was designed to compare spiral with standard-of-care Cartesian postcontrast structural brain MR imaging on the basis of relative performance in 10 metrics of image quality, artifact prevalence, and diagnostic benefit. MATERIALS AND METHODS: Seven clinical sites acquired 88 total subjects. For each subject, sites acquired 2 postcontrast MR imaging scans: a spiral 2D T1 spin-echo, and 1 of 4 routine Cartesian 2D T1 spin-echo/TSE scans (fully sampled spin-echo at 3T, 1.5T, partial Fourier, TSE). The spiral acquisition matched the Cartesian scan for scan time, geometry, and contrast. Nine neuroradiologists independently reviewed each subject, with the matching pair of spiral and Cartesian scans compared side-by-side, and scored on 10 image-quality metrics (5-point Likert scale) focused on intracranial assessment. The Wilcoxon signed rank test evaluated relative performance of spiral versus Cartesian, while the Kruskal-Wallis test assessed interprotocol differences. RESULTS: Spiral was superior to Cartesian in 7 of 10 metrics (flow artifact mitigation, SNR, GM/WM contrast, image sharpness, lesion conspicuity, preference for diagnosing abnormal enhancement, and overall intracranial image quality), comparable in 1 of 10 metrics (motion artifacts), and inferior in 2 of 10 metrics (susceptibility artifacts, overall extracranial image quality) related to magnetic susceptibility (P < .05). Interprotocol comparison confirmed relatively higher SNR and GM/WM contrast for partial Fourier and TSE protocol groups, respectively (P < .05). CONCLUSIONS: Spiral 2D T1 spin-echo for routine structural brain MR imaging is feasible in the clinic with conventional scanners and was preferred by neuroradiologists for overall postcontrast intracranial evaluation.

1 August 1992 in Proteins: Structure, Function, and Bioinformatics
Verified
Journal Article
Closed access
PDF file
CKCholl Wan Kim
Choll Wan Kim
MMMark Leo Michaels
Mark Leo Michaels
JMJeffrey H. Miller
Jeffrey H. Miller

28 December 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
MKMichael S. Kuwabara
Michael S. Kuwabara
TSThomas J. Sitzman
Thomas J. Sitzman
KSKathryn A. Szymanski
Kathryn A. Szymanski
JPJamie L. Perry
Jamie L. Perry
JMJeffrey H. Miller
Jeffrey H. Miller
PCPatricia Cornejo
Patricia Cornejo
SUMMARY: Up to 30% of children with cleft palate will develop a severe speech disorder known as velopharyngeal insufficiency. Management of velopharyngeal insufficiency typically involves structural and functional assessment of the velum and pharynx by endoscopy and/or videofluoroscopy. These methods cannot provide direct evaluation of underlying velopharyngeal musculature. MR imaging offers an ideal imaging method, providing noninvasive, high-contrast, high-resolution imaging of soft-tissue anatomy. Furthermore, focused-speech MR imaging techniques can evaluate the function of the velum and pharynx during sustained speech production, providing critical physiologic information that supplements anatomic findings. The use of MR imaging for velopharyngeal evaluation is relatively novel, with limited literature describing its use in clinical radiology. Here we provide a practical approach to perform and interpret velopharyngeal MR imaging examinations. This article discusses the velopharyngeal MR imaging protocol, methods for interpreting velopharyngeal anatomy, and examples illustrating its clinical applications. This knowledge will provide radiologists with a new, noninvasive tool to offer to referring specialists.

1 January 2001
Verified
Book Chapter
Closed access
KGK.N. Gracy
K.N. Gracy
JMJ.H. Miller
J.H. Miller

1 January 2001
Verified
Book Chapter
Closed access
JMJ.H. Miller
J.H. Miller