Glaykon Alex Vitti Stabile

Glaykon Alex Vitti Stabile

Auto-generated profile, based on publicly available information

Glaykon Alex Vitti Stabile

State University of Londrina

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2024 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Closed access
LFLucas Fernando de Oliveira Tomáz Ferraresso
Lucas Fernando de Oliveira Tomáz Ferraresso
JBJoão Felipe Besegato
João Felipe Besegato
GMGustavo Lopes Maler
Gustavo Lopes Maler
RTRicardo Takahashi
Ricardo Takahashi
GSGlaykon Alex Vitti Stábile
Glaykon Alex Vitti Stábile
MHMárcio Grama Hoeppner
Márcio Grama Hoeppner

24 October 2022 in Brazilian Dental Journal
Verified
Journal Article
Open access
ASAngelo Marcelo Tirado dos Santos
Angelo Marcelo Tirado dos Santos
GSGlaykon Alex Vitti Stabile
Glaykon Alex Vitti Stabile
KFKlissia Romero Felizardo
Klissia Romero Felizardo
SJSérgio Eduardo Ramos dos Santos Júnior
Sérgio Eduardo Ramos dos Santos Júnior
Sandrine Bittencourt BergerSandrine Bittencourt Berger
Sandrine Bittencourt Berger
MLMurilo Baena Lopes
Murilo Baena Lopes
The longevity of prosthetic rehabilitation is determined by the stability of the implant and abutment interfaces. True morse taper connections on dental restorations have been effective, however activation force still empirical. This work compared the activation strength and internal contact of Morse taper system according to the removal force. Eighty sets, composed of implants and prosthetic abutments, were evaluated with different internal contact areas; 15.12mm2 (G3.3) and 21.25mm2 (G4.3). The specimens were activated at 0° and 30°, with loads of 10, 20, 40 and 60N. The specimens were submitted to tensile test and the data to ANOVA and Tukey’s tests (α=0.05). Representative specimens were examined under SEM. Removal force of G3.3 (2.15±1.33MPa) did not differed to G4.3 (1.99±1.03MPa). The activation at 0º (2.95±0.98MPa) statistically differed to 30º (1.19±0.54MPa). The 60N load was statistically superior for G3.3 and there was no statistical difference between 20N to 60N in G4.3. The values of 10N at 30o and 20N at the long axis of the morse taper implant, independent of the frictional contact area showed the best settlement.

6 November 2023 in Revista da Faculdade de Odontologia - UPF
Verified
Journal Article
Open access
PDF file
JPJoão Vitor Pereira
João Vitor Pereira
KPKaroline Von Ahn Pinto
Karoline Von Ahn Pinto
LFLaís Albuquerque Fernandes
Laís Albuquerque Fernandes
GBGabriel Conceição Brito
Gabriel Conceição Brito
LMLigia Pozzobon Martins
Ligia Pozzobon Martins
GSGlaykon Alex Vitti Stabile
Glaykon Alex Vitti Stabile
Resumo Objetivo: relatar um caso de ferimento por arma de fogo, com projétil balístico alojado em região infraorbitária à esquerda, relatando tratamento cirúrgico de urgência para exérese do projetil por acesso subciliar. Relato do caso: Paciente do gênero masculino, 18 anos, foi encaminhado ao pronto socorro do Hospital Universitário por conta de ferimento por arma de fogo. Ao exame clínico, foi verificado discreto aumento de volume em região cervical e hemiface à esquerda, ausência de sangramento em face; presença de limitação para infraversão de olho esquerdo. O orifício de entrada do projetil foi identificado em região de tórax superior posterior à esquerda; após realização de tomografia de face, confirmou-se fratura de assoalho orbitário esquerdo, assim como projétil alojado abaixo do globo ocular. O ato cirúrgico foi realizado com caráter de urgência pela equipe de Cirurgia e Traumatologia Bucomaxilofacial. Discussão: estudos descrevem a importância da realização do adequado manejo de lesões traumáticas decorrentes de FAF seguido de remoção do projetil com urgência, visto que as complicações ao postergar o tempo cirúrgico só agravam o quadro clínico do paciente, além das afecções futuras que podem surgir com o decorrer da resolução do caso clínico. Conclusão: ratifica-se a importância da multidisciplinariedade entres as clínicas médicas, assim como, o correto manejo do paciente traumatizado, baseado nos critérios que conduzem o plano de tratamento.

24 January 2025 in Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
PDF file
FBFernanda Brasil Daura Jorge Boos-Lima
Fernanda Brasil Daura Jorge Boos-Lima
TKTalita de Carvalho Kimura
Talita de Carvalho Kimura
FHFlávia Akemi Nakayama Henschel
Flávia Akemi Nakayama Henschel
FCFernanda Herrera da Costa
Fernanda Herrera da Costa
JCJason E. Chen
Jason E. Chen
VVVanessa Cristina Veltrini
Vanessa Cristina Veltrini

1 January 2021 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
EDEDUARDO DALLAZEN
EDUARDO DALLAZEN
MQMariana Elias Queiroz
Mariana Elias Queiroz
ÂLÂngelo Rosso Llantada
Ângelo Rosso Llantada
MBMarcelo Medeiros Battistetti
Marcelo Medeiros Battistetti
CGChristopher Henrique Gibim
Christopher Henrique Gibim
GSGlaykon Alex Vitti Stabile
Glaykon Alex Vitti Stabile
Anophthalmia is mainly caused by two etiological groups, trauma and medical conditions. In addition, anophthalmia creates difficulties in social, professional, and family adaptation due to psychological, and functional disorders related to eye loss. Studies show a positive influence on the personal relationship of patients with anophthalmia after being rehabilitated with ocular prostheses. However, in order to achieve a good aesthetic result in prosthetic eye rehabilitation, it is essential that the size and positioning of the orbital skeleton are adequate. Facial trauma can also cause defects associated with bone loss, and in these cases, reconstructive techniques aim to restore the appropriate bone contour. The aim of this work is to report a case where reconstructive treatment was performed on a patient victim of a long-term traffic accident sequel, using an alloplastic implant in polymethylmethacrylate (PMMA) and bone repositioning, so that an ocular prosthesis could be made. At the end of the treatment, after reconstruction of the frontal-nasal region in PMMA and repositioning of the left zygoma, the aesthetic objectives were achieved and the patient improved his self-esteem and social life.

28 March 2021 in Research, Society and Development
Verified
Journal Article
Open access
PDF file
GGGuilherme Borsato Gomes
Guilherme Borsato Gomes
LCLeticia Sassaki Correia
Leticia Sassaki Correia
FFFernanda Schimidt de Freitas
Fernanda Schimidt de Freitas
VCVinicius Almeida Carvalho
Vinicius Almeida Carvalho
CSCecília Luiz Pereira Stabile
Cecília Luiz Pereira Stabile
GSGlaykon Alex Vitti Stabile
Glaykon Alex Vitti Stabile
Trauma to the jaw can lead to fracture of the mandibular condyle. Prevalence in children is low and treatment should focus on possible long-term effects on facial bone and soft tissue growth. Trauma can result in dysfunction, facial asymmetry, mandibular retraction, dysfunction and stiffness of the temporomandibular joint. Clinical examination and imaging tests are essential to obtain an accurate diagnosis and an effective treatment to avoid possible complications. Treatment can be surgical or non-surgical, but non-surgical treatment is the method of choice in most cases. The aim of this study is to report a case of mandibular condylar fracture in a pediatric patient who underwent conservative and functional care who, with adequate monitoring by the Maxillofacial Surgery and Traumatology team and family, showed complete remodeling of the fractured bone and total recovery of the dental occlusion. Treatment in pediatric patients through conservative management allows an adequate range of mandibular movement and remodeling at the fracture site, but patient and family adherence to treatment is very important to obtain good results.