Maximilian A. Jacobi

Maximilian A. Jacobi

Auto-generated profile, based on publicly available information

Maximilian A. Jacobi

Heart and Diabetes Center NRW, Institute of Anesthesiology and Pain Therapy, Ruhr University Bochum, 32545 Bad Oeynhausen, Germany

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2026 in Life
Verified
Journal Article
Open access
PDF file
MBMax Briefs
Max Briefs
MJMaximilian A. Jacobi
Maximilian A. Jacobi
ABAstrid Bergmann
Astrid Bergmann
MWMarc P. Woldt
Marc P. Woldt
PSPhilipp Sommer
Philipp Sommer
VDVera Von Dossow
Vera Von Dossow
The physiological effects of mechanical ventilation are subject to ongoing research. Conventional ventilation may contribute to pulmonary volutrauma or barotrauma and influence cardiovascular physiology through changes in intrathoracic pressure. In the multicenter Ablate-by-LAWT study, patients undergoing atrial fibrillation ablation were ventilated using a higher-frequency, low tidal ventilation (HFLTV) protocol. This post hoc single-center subgroup proof-of-concept study aimed to characterize physiological responses to HFLTV using left atrial pressure (LAP), gas exchange, and hemodynamic parameters during sequential, nonrandomized volume-controlled ventilation (VCV) and HFLTV. The ventilation protocols differed in respiratory rate, tidal volume, PEEP, FiO2, and I:E ratio. Twelve patients were included, and differences between ventilation strategies were assessed using two-sided paired t-tests. Compared with VCV, HFLTV was associated with lower systolic LAP (Mean Difference (MD) −3.33 mmHg, 95% confidence interval (CI) [−5.61; −1.06], p = 0.008), whereas post hoc estimated mean LAP was similar between ventilation periods (MD −0.06 mmHg, 95% CI [−2.19; 2.08], p = 0.955). Heart rate (MD 8.1 bpm, 95% CI [3.8; 12.4], p = 0.002), mean arterial pressure (MD 11.5 mmHg, 95% CI [7.1; 15.9], p < 0.001), and cardiac index (MD 0.64 L/min/m2, 95% CI [0.29; 0.99], p = 0.002) were higher during HFLTV. The partial arterial pressure of oxygen (PaO2) was lower during HFLTV (MD −42.3 mmHg, 95% CI [−83.5; −1.1], p = 0.045, FDR-adjusted p = 0.072), and the partial arterial pressure of carbon dioxide (PaCO2) (MD −1.1 mmHg, 95% CI [−6.0; 3.7], p = 0.623) and the PaO2/FiO2 ratio (MD −49.3 mmHg, 95% CI [−105.2; 6.7], p = 0.079) did not differ significantly. Given the fixed-order design and simultaneous modification of multiple ventilatory parameters, these exploratory findings should be considered hypothesis-generating and cannot be attributed to individual components of the HFLTV protocol.