Alaettin Ozer

Alaettin Ozer

Auto-generated profile, based on publicly available information

Alaettin Ozer

Department of Mechanical Engineering, Bozok University, Yozgat, Turkey

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2008 in Tribology International
Verified
Journal Article
Closed access
HSHasan Sofuoglu
Hasan Sofuoglu
AOAlaettin Ozer
Alaettin Ozer

8 July 2024 in Polymer Composites
Verified
Journal Article
Closed access
HMHalil Burak Mutu
Halil Burak Mutu
AÖAlaettin Özer
Alaettin Özer

19 September 2022 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
AOAlaettin Ozer
Alaettin Ozer
Background: The effect of posterior tibial slope on the maximum contact pressure and wear volume of polyethylene (PE) insert were not given special attention. The effects of flexion angle, Anterior-Posterior (AP) Translation, and Tibial slope on the max contact pressure and wear of PE insert of TKR were investigated under loadings which were obtained in cadaver experiments by using Archard’s wear law. This study uses not only loads obtained from cadaver experiments but also dynamic flexion starting from 0 to 90 degrees. Method: Wear on knee implant PE insert was investigated using a 2.5 size 3 dimensional (3D) cruciate sacrificing total knee replacement model and Finite Element Method (FEM) under loadings and AP Translation data ranging from 0 to 90 flexion angles validated by cadaver experiments. Two types of analyses were done to measure the wear effect on knee implant PE insert. The first set of analyses included the flexion angles dynamically changing with the knee rotating from 0 to 90 angles according to the femur axis and the transient analyses for loadings changing with a certain angle and duration. Results: It is seen that the contact pressure on the PE insert decreases as the cycle increases for both Flexion and Flexion+AP Translation. It is clear that as the cycle increases, the wear obtained for both cases increases. The loadings acting on the PE insert cannot create sufficient pressure due to the AP Translation effect at low speeds and have an effect to reduce the wear, while the effect increases with the wear as the cycle increases, and the AP Translation now contributes to the wear at high speeds. It is seen that as the posterior tibial slope angle increases, the maximum contact pressure values slightly decrease for the same cycle. Conclusions: This study indicated that AP Translation, which changes direction during flexion, had a significant effect on both contact pressure and wear. Unlike previous similar studies, it was seen that the amount of wear continues to increase as the cycle increases. This situation strengthens the argument that loading and AP Translation values that change with flexion shape the wear effects on PE Insert.

1 October 2015 in International Journal of Adhesion and Adhesives
Verified
Journal Article
Closed access
AOAlaettin Ozer
Alaettin Ozer


6 July 2022 in Joint Diseases and Related Surgery
Verified
Journal Article
Open access
PDF file
AÖAlaettin Özer
Alaettin Özer
KÖKerim öner
Kerim öner
AOAhmet Emin Okutan
Ahmet Emin Okutan
MAMuhammet Salih Ayas
Muhammet Salih Ayas
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.