17 March 2020 in IEEE Open Journal of Industry Applications
The effects of distribution-connected solar farms on the transmission and distribution systems are studied in this paper using a practical power system network. Both the transmission and distribution networks are modeled and co-simulated for intermittent effects of solar power and changing load profiles. These effects include, flicker in both the transmission and the distribution systems, operation of the substation Load Tap Changer (LTC) and feeder regulators, and distribution feeder voltage profiles. The results of the study show a potential hunting effect causing excessive LTC operation especially during periods of high reverse power flow condition and a significant visible flicker in the distribution system but lower levels of flicker at the transmission level. It is shown that the hunting behavior of the LTC can be mitigated and downstream feeder voltage profiles can be improved via enhanced bandwidth, block operation mode, and adjusting time delay of the substation LTC controller. In addition, the inverter Volt-Var control can be used to effectively diminish excessive LTC operation based on IEEE Std 1547-2018 Volt-Var characteristics with modified settings. Finally, an enhanced load-flow algorithm with modified Jacobian is presented that incorporates the Distributed Energy Resource (DER) Volt-Var characteristics in the conventional Newton-Raphson method.
8 May 2019 in IEEE Transactions on Industrial Electronics
Interconnected dc grids are studied in this paper, which comprise resistive and constant-power loads (CPLs) fed by Photovoltaic (PV) units. All the sources and CPLs are connected to the grid via dc-dc converters. Nonlinear behavior of PV units in addition to the effect of negative-resistance CPLs can destabilize the dc grid. Thus, decentralized nonlinear model and intelligent control are proposed using adaptive output-feedback controller to stabilize the grid. The use of the output-feedback control makes possible the utilization of other available signals, in case of loss of main signal, at the converter location and creates measurement redundancy that improves reliability of the dc network. The switching between measured signals of different types are performed through using the neural network (NN) controllers without the need to further tuning. The stability of the entire network is assured through Lyapunov stability method while each converter employs only local measurements. The adaptive neural networks are utilized to overcome the unknown dynamics of the dc-dc converters at distributed energy resources (DERs) and CPLs and those of the interconnected network imposed on the converters. Simulation and experimental results are provided on a small-scale dc grid to show the effectiveness of the developed model and the proposed controller.
21 December 2021 in IEEE Transactions on Industry Applications
A coupled load flow algorithm is developed to perform transmission and distribution (T&D) co-simulation. Subsequently, the effects of distributed energy resources (DERs) on the dynamics of power systems are studied by extending the T&D load flow algorithm to T&D dynamic co-simulation. The detailed distribution and transmission systems are modeled separately and are coupled at the substation nodes at each time step. Dynamics of the DER_A mechanisms are modeled separately downstream of the distribution substation using the North American Electric Reliability Corporation model (NERC-2018). The effects of the DER_A settings are examined on the dynamics of the transmission system and DER operation. In addition, lumped and distributed induction motor load models are compared at the distribution level. The results of the study show that under high DER penetration excessive operation may occur at the distribution load tap changers. Also, the effect of reactive power on voltage recovery is significant under DER high fault-ride-through capability and DER reactive current injections. Moreover, it is observed that DER frequency control may adversely affect the DER operation keeping the active and reactive currents at high levels due to frequency deviations. Finally, distributed induction motor loads stimulate more DER reactive power injection causing voltage overshoots.
12 August 2021 in IEEE Transactions on Industry Applications
Hybrid ac-dc grids can gain the benefits of both ac and dc grids. The ac-dc circuit analysis can be performed using sequential methods that decouple ac and dc systems or unified (simultaneous) methods that solve the ac and dc mismatch equations simultaneously. This paper introduces a unified ac-dc analysis via an improved model for the ac-dc coupling through which the ac and dc load flow analyses can be simultaneously conducted. The ac-dc coupling is modeled by an admittance building block, and thus, the dc grid is converted to an ac-equivalent circuit within the hybrid network. However, unlike past literature, state variables beyond nodal voltages and angles are avoided, leading to a simpler algorithm, and reactive power injection of the coupling mechanism, a requirement for the IEEE 1547, is explicitly modeled. Furthermore, the proposed model can be applied to both voltage-source and line-commuted converters (VSCs & LLCs). Accordingly, the conventional ac power flow algorithms can be applied to the hybrid circuit paving the path for seamless adoption of hybrid circuits and significantly saving time and effort in programming, troubleshooting, and upgrading techniques currently used in research and industry as well as a high-level analysis tool regarding the hybrid ac-dc grid is achieved.
1 May 2026 in IEEE Transactions on Industry Applications