Anghel Cernescu

Anghel Cernescu

Auto-generated profile, based on publicly available information

Anghel Cernescu

School of Engineering, Cardiff University, Cardiff, UK

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2013 in Engineering Failure Analysis
Verified
Journal Article
Closed access
ACAnghel Cernescu
Anghel Cernescu
IDI. Dumitru
I. Dumitru
NFN. Faur
N. Faur
NBN. Branzei
N. Branzei
RBR. Bogdan
R. Bogdan

1 October 2018 in Surface Engineering
Verified
Journal Article
Closed access
AMAlin Constantin Murariu
Alin Constantin Murariu
ACAnghel Vasile Cernescu
Anghel Vasile Cernescu
IPIon-Aurel Perianu
Ion-Aurel Perianu
This paper presents the effect of saline environment on the fatigue behaviour of high-velocity oxygen fuel thermal-sprayed WC–CrC–Ni coatings. These coatings are used to improve the surface hardness, corrosion and wear resistance of components or products, in the place of hard chrome plating. Although so far many tests on the wear and corrosion of coating behaviour were carried, the conduct of the joint action fatigue – a corrosive environment is not fully identified. In the frame of the experimental programme, similar axial fatigue tests at room temperature, on air or on specimens immersed in 3% NaCl solution and also chemical composition, structural analysis of the fracture surface were performed, using SEM and EDX. The saline environmentcauses material corrosion, generation of voids and microcracks on the specimen surface and their propagation through the specimen cross-section, accelerating the specimen failure.

1 December 2015 in Composite Structures
Verified
Journal Article
Closed access
ACAnghel Cernescu
Anghel Cernescu
JRJani Romanoff
Jani Romanoff

30 July 2020 in The Journal of Strain Analysis for Engineering Design
Verified
Journal Article
Open access
PDF file
RPRhys Pullin
Rhys Pullin
IJIfan Jenkins
Ifan Jenkins
ACAnghel Cernescu
Anghel Cernescu
AEAllen Edwards
Allen Edwards
The small punch test initially used mainly in the nuclear sector proved to be an efficient method of estimating the mechanical properties of materials, including fracture toughness. In general, the fracture toughness is estimated based on a correlation with equivalent biaxial fracture strain. However, the latter depends on knowing the onset of the unstable fracture. In this article, the acoustic emission technique is used within the small punch test for estimating the unstable fracture initiation and determining the corresponding punch displacement from the load–displacement curve. Although, the acoustic emission signal can be slightly altered due to the location of the sensor, the results confirm the potential of the acoustic emission technique for detecting the onset of the unstable cracking and thus accurately estimating the equivalent biaxial fracture strain. The accumulated energy during the small punch test is one of the relevant acoustic emission parameters in estimating the fracture onset since it can be associated with the accumulated strain energy released by the deformed material.

1 February 2018 in Implant Dentistry
Verified
Journal Article
Closed access
Sorin Gheorghe MihaliSorin Gheorghe Mihali
Sorin Gheorghe Mihali
SCSilvana PhD Canjau
Silvana PhD Canjau
ACAnghel Cernescu
Anghel Cernescu
CBCristina M. PhD Bortun
Cristina M. PhD Bortun
HWHom-Lay PhD Wang
Hom-Lay PhD Wang
EBEmanuel PhD Bratu
Emanuel PhD Bratu
Purpose: To establish a protocol for reducing the drilling sequence during implant site preparation based on temperature and insertion torque. The traditional conventional drilling sequence (used several drills with 0.6-mm increment each time) was compared with the proposed short drilling protocol (only used 2 drills: initial and final drill). Materials and Methods: One hundred drilling osteotomies were performed in bovine and porcine bones. Sets of 2 osteotomy sites were created in 5 bone densities using 2 types of drilling protocols. Thermographic pictures were captured throughout all drilling procedures and analyzed using ThermaCAM Researcher Professional 2.10. Torque values were determined during drilling by measuring electrical input and drill speed. Results: There were statistically significant differences in bone temperature between the conventional and short drilling protocols during implant site preparation (analysis of variance P = 0.0008). However, there were no significant differences between the 2 types of drilling protocols for both implant diameters. Implant site preparation time was significantly reduced when using the short drilling protocol compared with the conventional drilling protocol (P < 0.001). Conclusions: Within the limitations of the study, the short drilling protocol proposed herein may represent a safe approach for implant site preparation.

2 December 2019 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
ACAnghel Cernescu
Anghel Cernescu
RPRhys Pullin
Rhys Pullin
One of the challenges regarding multiaxial fatigue damage predictions is non-proportional loading. Relevant studies have shown that these multiaxial loadings cause significant additional hardening and reduction in durability due to non-proportionality. Fatigue life predictions due to non-proportional loadings are based on an equivalent non-proportional strain range that considers a material constant related to additional hardening and a non-proportionality factor. In this paper an analysis of the non-proportional factor for three multiaxial loadings forming a square in γ/√3 – ε coordinates is carried out. One of the observations revealed by this analysis is the sensitivity of the non-proportional factor to variable shear strain rate.