Eyyup Demirkutlu

Eyyup Demirkutlu

Auto-generated profile, based on publicly available information

Eyyup Demirkutlu

Department of Power and Control Systems Design Engineering, ASELSAN, Ankara, Trkiye

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2009 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
EDEyyup Demirkutlu
Eyyup Demirkutlu
AHAhmet M. Hava
Ahmet M. Hava
An all-scalar-control and pulsewidth-modulation (PWM) approach for the four-leg-inverter (FLI)-based three-phase transformerless four-wire power supply (PS) is proposed. The output voltage of each phase is controlled independently, and its controller is formed by a stationary-frame resonant-filter bank accompanied with proportional-control and output-capacitor current-based active-damping loops. The simple and easy to implement scalar-control method exhibits superior overall steady-state and dynamic performance in the PS applications involving loads with high crest factor and/or significant load imbalance. Utilizing the inverter zero-state partitioning, a generalized form of scalar PWM for the FLI is developed. A novel minimum loss discontinuous PWM method, which provides minimum switching losses under all loading conditions (including load imbalance), is derived. This simple scalar method provides superior performance, and unlike the vector methods, it is easy to implement. The controller and modulator design and implementation details for the system are given. Linear and nonlinear loads for balanced and imbalanced load operating conditions are considered. The scalar-control and PWM methods are proven by means of theory, simulations, and thorough laboratory experiments of a 5-kVA PS.

1 May 2007
Verified
Conference Paper
Closed access
EDEyyup Demirkutlu
Eyyup Demirkutlu
SCSuleyman Cetinkaya
Suleyman Cetinkaya
AHAhmet M. Hava
Ahmet M. Hava
A method for high performance output voltage control of a four-leg inverter (FLI) based three-phase UPS is proposed. Stationary frame resonant filter bank based output voltage control loop, which is complemented by capacitor current feedback based active damping loop, is employed. Utilizing the zero-state partitioning variable, a generalized form of scalar PWM for the FLI is developed and the minimum loss discontinuous PWM method is derived. The controller and modulator design and implementation details for the FLI-UPS are given. Linear and nonlinear loads for balanced and unbalanced load operating conditions are considered. The scalar control and PWM methods are proven by means of theory, simulations, and experiments.

17 January 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
EDEyyup Demirkutlu
Eyyup Demirkutlu
İİİres İskender
İres İskender
A transformerless, single-phase, buck–boost inverter is proposed in this study. Unlike similar topologies, the proposed inverter does not need to have a mid-point of dc sources or dc-bus capacitors at the input side of the inverter. The proposed inverter can suppress the leakage current drawn from the input power source and provide a long-lasting solution for applications with a wide input voltage range and/or unregulated input voltage. This article presents the controller and modulation design details, and a comparative evaluation conducted for the proposed inverter. A single-phase, buck–boost inverter for realizing the power stage with 110 V rms output ac voltage and a range of 100–200 V input dc voltage is investigated in this study. The proposed inverter has been proven through theory, computer simulations, and experimental studies with SiC mosfet s-based prototype of a 300 VA power supply. Theory, computer simulation, and experimental results are all correlated.

1 January 2007
Verified
Conference Paper
Closed access
AHAhmet M. Hava
Ahmet M. Hava
EDEyyup Demirkutlu
Eyyup Demirkutlu
An all scalar PWM and control approach for the four-leg inverter based three phase transformerless UPS is proposed. The output voltage of each phase is controlled independently and its controller is formed by a stationary frame resonant filter bank accompanied with proportional control and output capacitor current based active damping loops. The resonant filter bank consists of the fundamental component controller and one controller for each dominant harmonic. The simple to implement scalar control method exhibits superior overall steady-state and dynamic performance in the UPS application. Utilizing the inverter zero- state partitioning, a generalized form of scalar PWM for the four-leg inverter is developed. A novel minimum loss discontinuous PWM (MLDPWM) method, which provides minimum switching losses under all operating conditions (including unbalanced load operation) is derived. This simple scalar method provides superior performance and unlike the vector methods it is easy to implement. The controller and modulator design and implementation details for the system are given. Linear and nonlinear loads for balanced and unbalanced load operating conditions are considered. The scalar control and PWM methods are proven by means of theory, simulations, and thorough laboratory experiments of a 5 kVA UPS system.

1 June 2017
Verified
Conference Paper
Closed access
EDEyyup Demirkutlu
Eyyup Demirkutlu
SCSendogan Cakmakci
Sendogan Cakmakci
KCKoray Celik
Koray Celik
COCaglar Ozyurt
Caglar Ozyurt
In space applications, one of the main issues is to obtain an efficient power supply. There are various types of energy sources to produce electrical power which is needed for the operation of all active spacecraft systems and subsystems. Due to the dependency of distance from the Sun, solar energy source has limited application area. On the other hand, nuclear energy sources are widely preferred to provide electrical power during many deep space and planetary science missions. Using the radioactive decay process or fission reactor, nuclear energy is converted to thermal energy. This thermal energy can be used directly for heating issues or converted to electrical energy. Thermal energy is converted to electrical energy by means of both static and dynamic thermo-electric conversion technologies. An overview of nuclear energy technologies and nuclear energy based power systems utilized in the deep space missions take place in this paper.