Qing-Qing Tan

Qing-Qing Tan

Auto-generated profile, based on publicly available information

Qing-Qing Tan

Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan, China; Medical School of Ophthalmology & Optometry, North Sichuan Medical College, Nanchong, Sichuan, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
QTQing-Qing Tan
Qing-Qing Tan
SCStephen P Christiansen
Stephen P Christiansen
JWJingyun Wang
Jingyun Wang
To investigate refractive error development in preterm children with severe retinopathy of prematurity (ROP) treated with anti-vascular endothelial growth factor (anti-VEGF) agents and laser photocoagulation. Selection criteria were comparative studies that compared the refractive errors in children, birthweights ≤1500 grams and gestational ages ≤30 weeks, and treatments for Type I ROP with intravitreal bevacizumab (IVB) versus laser photocoagulation. Studies were identified using PubMed, Google Scholar, and published reviews. Meta-analyses were performed on the post-treatment outcomes of spherical equivalent (SEQ), cylindrical power, and prevalence of high myopia. Longitudinal development of refractive error in IVB, or in laser-treated children, or in normal full-term children was visually summarized. Two randomized controlled trials and 5 non-randomized studies, including a total of 272 eyes treated by IVB and 247 eyes treated by laser, were included in this study. Compared with laser-treated children, IVB-treated children have less myopic refractive error (P<0.001), lower prevalence of high myopia (P<0.05), and less astigmatism (P = 0.02). Treatment with IVB is associated with less myopia and astigmatism than laser treatment for infants with severe ROP. Given the complexity of ROP and the variability of dosing, our review supports close monitoring of refractive error outcomes in children treated with IVB.

21 February 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XLXuan Liao
Xuan Liao
YPYue Peng
Yue Peng
BLBo Liu
Bo Liu
QTQing-Qing Tan
Qing-Qing Tan
CLChang-Jun Lan
Chang-Jun Lan
This prospective cross-sectional study aimed to evaluate the agreement of two new biometers for measuring ocular biometric parameters in young healthy eyes. Ocular biometric parameters were measured using IOLMaster 700 and OA-2000. Power vector analyses of Cartesian (J0) and oblique (J45) components of corneal astigmatism were performed. The right eyes of 103 healthy volunteers were analyzed. The 95% limits of agreement ranged from −0.03 to 0.03 mm, −0.08 to 0.07 mm, −0.18 to 0.18 diopters (D), −1.09 to 1.16 D, −1.18 to 1.15 D for axial length (AL), anterior chamber depth (ACD), mean keratometry, J0 and J45 respectively, which were all comparable between the two biometers, while significant differences were detected in lens thickness (LT), central corneal thickness (CCT), white-to-white (WTW) and pupil diameter (PD). Predicted intraocular lens (IOL) powers were comparable between the two biometers by Haigis and Barrett Universal II formulas, while not by SRK/T, Hoffer Q and Holladay 2. Excepting CCT, WTW and PD meaurements, IOLMaster 700 and OA-2000 have excellent agreement on ocular biometric measurements and astigmatism power vectors, which provides more options for ocular biometric measurements and enables constant optimization for IOL power calculation.

9 April 2018 in Current Eye Research
Verified
Journal Article
Closed access
XLXuan Liao
Xuan Liao
JLJia Lin
Jia Lin
JTJing Tian
Jing Tian
BWBaiWei Wen
BaiWei Wen
QTQingQing Tan
QingQing Tan
CLChangJun Lan
ChangJun Lan
To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.

18 August 2022 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
SASaeed Aljohani
Saeed Aljohani
SASulaiman Aldakhil
Sulaiman Aldakhil
SASaif Hassan Alrasheed
Saif Hassan Alrasheed
QTQing-Qing Tan
Qing-Qing Tan
SASaleh Alshammeri
Saleh Alshammeri
Purpose: To provide the clinical characteristics of amblyopia in children under 17 years of age in Qassim Region, Saudi Arabia. Patients and Methods: The study was a cross-sectional hospital-based, included 121 children with amblyopia aged between 3 and 17 years, referred from 6 hospitals in Qassim region to the paediatric optometry clinic at Qassim University medical city. Demographics and comprehensive ocular examination including visual acuity (VA), assessment of anterior and posterior segment, cycloplegic refraction (RE), angle of deviation, and cause of amblyopia were collected. Results: The mean age at diagnosis of amblyopia was 8.93 ± 3.67 years. The leading cause of amblyopia was strabismus and anisometropia shared the same percentage at 29.75%, and the combined-mechanism at 18.18%. Amblyopia was more common in males 57.85%, particularly strabismic amblyopia in 66.67% and anisometropic amblyopia in 61.11%, p = 0.408. Amblyopia was more predominant in the age group 6- to 9-year-old, particularly, strabismic amblyopia 44.44%, and amblyopia due to a combined mechanism of 36.36%, p = 0.066. The degree of hyperopia was not varied by the cause of amblyopia (P = 0.401), with slightly high hyperopia found in ametropic and strabismic amblyopia. Conversely, hyperopic astigmatism was significantly associated with amblyopia P = 0.020, with a high degree of hyperopic astigmatism found in meridional amblyopia and ametropic amblyopia. Conclusion: The commonest types of amblyopia in children were attributed to strabismus and anisometropia. Causes of amblyopia differed by age group with strabismus, anisometropia, and combined mechanism accounting for most children aged 6- to 9-years and strabismus for children aged less than 6 years. Hyperopic and myopic astigmatism were significantly associated with anisometropia and meridional amblyopia. Therefore, efforts should be made for early diagnosis and management of childhood amblyopia and uncorrected refractive errors to avoid their impact on quality of life.

18 July 2019 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
QTQing-Qing Tan
Qing-Qing Tan
JLJia Lin
Jia Lin
JTJing Tian
Jing Tian
XLXuan Liao
Xuan Liao
CLChang-Jun Lan
Chang-Jun Lan
To compare the postoperative optical quality in eyes with customized selection and random selection of aspheric intraocular lens (IOL) implantation. A prospective, nonrandomized study was implemented in adult cataract patients who underwent unilateral phacoemulsification with aspheric IOL implantation. Patients were allocated into two treatment groups: a customized group and a control group. In the customized group, the aspheric IOL selection was based on the corneal spherical aberration to enable the postoperative target ocular spherical aberration closest to zero; in the control group, the aspheric IOLs were chosen using a random strategy. Primary outcome measurements included the following objective optical quality assessments: higher-order aberrations obtained by a Hartmann-shack aberrometer at 4 mm and 6 mm pupil diameters; objective scatter index (OSI), modulation transfer function (MTF) cut-off, Strehl ratio (SR) and a simulated contrast visual acuity—optical quality analysis system value (OV) obtained by a double-pass system with a 4-mm aperture. Subjective visual acuity was measured as secondary outcome. All the patients were followed up for 3 months. Eighty-four patients in the customized group and 78 patients in the control group were evaluated. There was no significant difference in postoperative visual acuity between the two groups (P > 0.05). Significantly less ocular higher-order aberrations were shown in the customized group (P < 0.05). No significant difference was shown in OSI, MTF cut-off, SR and OV between the two groups (P > 0.05). Although customized selection of aspheric IOL implantation showed less postoperative ocular aberrations, it performed similarly to random selection of aspheric IOL implantation in terms of postoperative visual acuity, simulated contrast visual acuity, intraocular scatter, modulation transfer function and Strehl ratio. Retrospectively registered on 07/06/2019. Registration number: ChiCTR1900024356 .

23 October 2019 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
QTQing-Qing Tan
Qing-Qing Tan
BWBai-Wei Wen
Bai-Wei Wen
XLXuan Liao
Xuan Liao
JTJing Tian
Jing Tian
JLJia Lin
Jia Lin
CLChang-Jun Lan
Chang-Jun Lan