Representative Publications

View All Publications
30 August 2024 in JHEP Reports
Verified
Journal Article
Open access
OÖOsman Öcal
Osman Öcal
ODOlaf Dietrich
Olaf Dietrich
SLSergio Lentini
Sergio Lentini
PBPierre Bour
Pierre Bour
TFThibaut Faller
Thibaut Faller
MSMax Seidensticker
Max Seidensticker
MRI guidance offers better lesion targeting for microwave ablation of liver lesions with higher soft-tissue contrast, as well as the possibility of real-time thermometry. This study aims to evaluate the correlation of real-time MR thermometry-predicted lesion volume with the ablation zone in postprocedural first-day images. This single-center retrospective analysis evaluated prospectively included patients who underwent MRI-guided microwave ablation with real-time thermometry between December 2020 and July 2023. All procedures were performed under general anesthesia on a 1.5 T MRI scanner. Real-time thermometry data were acquired using multi-slice gradient-echo echoplanar imaging sequences, and thermal dose maps (CEM43 of 240 min as a threshold) were created. The volume of tissue exposed to a lethal thermal dose in MR thermometry (thermal dose) was compared with the ablation zone volume in portal phase T1w MRI on the postprocedural first day using the Pearson correlation test, and visual quantitative assessment by radiologists was performed to evaluate the similarity of shapes and volumes. Out of 30 patients with 33 lesions with thermometry images, six (18.1%) lesions were excluded because of artifacts limiting interpretation of thermal dose volume. Twenty-four patients with 27 lesions (20 male, age 63.1 ± 9.1 years) were evaluated for the volume correlation. The volume of thermal dose-predicted lesions and the postprocedural first-day ablation zones showed a strong correlation (R = 0.89, p <0.001). Similarly, visual similarity of molecular resonance thermometry-predicted shape and the ablation zone shape was graded as perfect in 23 (85.1%) lesions. Real-time thermal dose-predicted volumes show very good correlation with the ablation zone volumes in images obtained 1 day after the procedure, which could reduce the local recurrence rates with the possibility of re-ablating lesions within the same procedure. Heat-based ablation is an established treatment for liver tumors; however, there is a considerable rate of incomplete treatment because of the lack of real-time visualization of the treated area during treatment. Our results show that MRI-guided ablation enables the visualization of the treatment area in real-time with high accuracy using a special technique of MR thermometry in patients with liver tumors.

16 November 2024 in Computers in Biology and Medicine
Verified
Journal Article
Open access
MDManon Desclides
Manon Desclides
VOValéry Ozenne
Valéry Ozenne
PBPierre Bour
Pierre Bour
TFThibaut Faller
Thibaut Faller
GMGuillaume Machinet
Guillaume Machinet
BQBruno Quesson
Bruno Quesson
Clinical Laser-Induced Thermotherapy (LITT) currently lacks precise control of tissue temperature increase during the procedure. This study presents a new method to automatically regulate the maximum temperature increase in vivo at different positions by adjusting LITT power delivered by multiple laser probes using real-time volumetric MR-thermometry. The regulation algorithm was evaluated in vivo on a pig leg muscle. Temperature regulation was performed in volumes surrounding each laser probe tip. The power delivered to each laser probe was automatically adjusted every second using a feedback control algorithm by processing on-the-fly MR-thermometry images (10 slices/second) on a 1.5 T clinical scanner (1.56 mm × 1.56 mm x 3 mm resolution), using the proton-resonance frequency (PRF) shift technique. Several experimental conditions were tested with predefined temperature-time profiles corresponding to conditions of thermal ablation (+30 °C above body temperature) or moderate hyperthermia (+10 and + 15 °C). Control images were acquired after injection of Gadolinium at the end of experiment and were compared with the thermal dose images calculated from the thermometry images. The mean difference and root mean squared error between target temperatures and measured ones remained below 0.5 °C and 2 °C respectively, for 5 min duration. Lesion sizes observed on thermal dose and on images acquired after gadolinium injection were in good agreement. Automatic regulation of in vivo temperature increase during LITT procedures with multiple laser emitters control is feasible. The method provides an adaptative solution to improve the safety and efficacity of such clinical procedures.

16 October 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
EDEber Dantas
Eber Dantas
RLRebecca Lafont
Rebecca Lafont
PBPierre Bour
Pierre Bour
TFThibaut Faller
Thibaut Faller
BQBruno Quesson
Bruno Quesson
VOValéry Ozenne
Valéry Ozenne
Purpose: Real‐time monitoring of microwave liver ablation (MWA) using MRI thermometry can be hindered by boiling‐induced susceptibility artifacts. These artifacts cause large temperature measurement errors that prevent accurate lesion size prediction. This study proposes a correction methodology based on removing the contribution of this susceptibility artifact using subvoxel sources of susceptibility. Methods: In vivo microwave ablations ( N = 23) were performed on seven pig livers and the temperature was monitored using the proton resonance frequency shift (PRFS) method. The boiling‐induced artifacts were observed in 11 ablation cases. To validate the proposed methodology, the thermal dose was computed from the corrected temperature maps, and the resulting lesion estimates were compared in three dimensions with ground‐truth lesion segmentations derived from post‐ablation T1w images. A numerical simulation was also conducted to emphasize the need for a finer spatial discretization. Results: After correction, a better agreement was noticed between thermal dose prediction and lesion size. Over the 11 cases observed with boiling‐induced susceptibility artifacts, the median volumetric Dice, Total Overlap, and False Negative rates changed by 4.8%, 6.2%, and −11.4%. Conclusion: Comparison with T1w imaging showed improvements in prediction of lesion volume. The proposed methodology takes into account partial volume effects and the contribution of adjacent slices. It was able to simulate a diverse range of deformed dipole‐like artifacts observed in experimental data.